Document number: ED000812C
Page | 12
3.9
Environmental
Table 7. Environmental characteristics
Temperature
Operating
-40 °C to +85 °C
Operating Survival
-50 °C to +95 °C
Storage
-50 °C to +105 °C
Humidity
Non-condensing, operating
93% RH max at +40 °C, per IEC 60068-2-78
Condensing, non-operating
95% RH max at +55 °C, per IEC 60068-2-30
Altitude
Operating/non-operating
0 to 18 km (58k ft), per IEC 60068-2-13
Vibration
Random
Operating/non-operating
0.05 g
2
/Hz, ASD level, 5-500 Hz
per IEC 60068-2-64, test Fdb.
Shock
Operating/non-operating
100 g, 6 ms, half sine wave per
IEC60068-2-27, test Ea.
3.10
Reliability
The display MTBF is to be greater than 50,000 hours at 120 Hz with a 90% confidence level
at 25 °C.
3.11
Safety and EMI performance
The display will not inhibit the end product from obtaining these certifications: IEC 950, IEC
601-1-1, UL2601, CSA 22.2 #601-M89, FCC Docket, Part 15, Subpart J, Class B; CISPR22,
Class B; and VDE 871/VFG243 Class B.
3.12
Optional features
Conformal coating and anti-glare filters are available as an option.