Figure 4. 6800 Video input timing diagram
Table 6. 6800 Video input timing description
Signal
Symbol
Parameter
Condition
min
max
Unit
A0, /CS,
t
CYC6
System cycle time
550
-
ns
R//W
t
AW6
Address setup time
0
t
AH6
Address hold time
0
-
ns
t
DS6
Data setup time
100
-
ns
CL=100 pF
D0 to D7
t
DH6
Data hold time
0
-
ns
t
OH6
Output disable time
10
50
ns
t
ACC6
Access time
-
85
ns
E
t
EW
Enable pulse width
120
All signals
Tr, Tf
Input rise and fall
times
30
ns