CHK
ADJ
- 69 -
ELECTRIC SYSTEM/CHECK AND BATTERY CHARGE
BATTERY
CHARGE METHOD USING A CHARGER WITH VARIABLE CURRENT (VOLTAGE)
NOTE:
-
Measure the voltage 30 minutes after switching off
the equipment.
-
Set the charge voltage to 16 ~ 17 V. (A lower setting
will not give suffi cient charge.
-
A setting that is too high will overload the battery).
Ruotando la rotella di
regolazione
della tensione di ricarica,
impostare
la tensione di ricarica
su 20 ~ 24 V.
Tenere sotto controllo
l’amperaggio
per 3 ~ 5 minuti
per verificare
se la corrente di carica
standard viene raggiunta.
Se la corrente non supera
la corrente di
carica standard
una volta trascorsi
5 minuti, sostituire la
batteria.
Se per la ricarica sono necessarie più di 5 ore, è consigliabile controllare la corrente di carica dopo 5 ore.
Se si verificano variazioni dell’amperaggio, regolare nuovamente la tensione per ottenere la corrente di
carica standard.
Misurare la tensione a circuito aperto della batteria dopo averla lasciata per più di 30 minuti inutilizzata.
12.8 V o superiore La ricarica è completa
12.7 V o inferiore
Ricarica necessaria.
Inferiore a 12.0 V
Sostituire la batteria.
Misurare la tensione a circuito aperto
prima di procedere con la ricarica.
Collegare alla batteria un
caricabatterie e un amperometro
e iniziare la ricarica.
Verificare che la corrente sia più elevata
del valore standard della corrente di
ricarica riportato sulla batteria.
Regolare la tensione in modo
tale che la corrente sia al livello
di carica standard.
Impostare il tempo in base
al tempo di ricarica adatto
per la tensione a circuito
aperto.
Vedere le istruzioni
incluse alla batteria.
NO
NO
SI
SI
A
Caricabatterie
Amperometro
Measure the voltage at open circuit before
charging
Connect a battery charger and an ammeter
to the battery and start charging
Check the current is higher than the stan-
dard value of the charge one indicated on
the battery
By rotating a charge voltage
setting roller, set the charge
voltage to 20 ~ 24 V
Set the voltage so that the current is equal to
standard charge level
YES
Monitor the amps for 3 ~ 5
minutes to check if the standard
charge current is reached
Set time according to charge
time suitable for the voltage in
an open circuit.
Refer to instructions supplied
with the battery
Should current not exceed the
standard charge current after
5 minutes, replace the battery
In case it takes more than 5 hours for charge, it is recommended to check the charge current after 5 hours.
In the event of amps changes, set again the voltage to obtain the standard charge current
Measure the battery open circuit voltage after a downtime of 30 minutes.
12.8 V or higher > Charge is complete
12.7 V or lower >Charge necessary
Lower than 12.0V > Replace the battery
Ammeter
Battery charger
YES
All manuals and user guides at all-guides.com
Summary of Contents for BN600R 2014
Page 19: ...SPEC 18 SPEC Specifications CHAPTER 2 All manuals and user guides at all guides com ...
Page 40: ...CHK ADJ 39 NOTES All manuals and user guides at all guides com ...
Page 80: ...CHAS 79 Frame CHAPTER 4 CHAS All manuals and user guides at all guides com ...
Page 175: ... 174 ENG ENG Engine CHAPTER 5 All manuals and user guides at all guides com ...
Page 232: ...COOL 231 COOL Cooling system CHAPTER 6 All manuals and user guides at all guides com ...