Connecting to a Power Source
The Power Unit must be connected to an appropriate power source.
⚠
DANGER
All wiring
must
be performed by a licensed, certified Electrician. Do not perform
any maintenance or installation on the Lift without first making sure that main
electrical power has been disconnected from the Lift and cannot be re-energized
until all procedures are complete. The Lift uses electrical energy; if your organization
has Lockout/Tagout policies, make sure to implement them after connecting to a
power source.
Important
: Make clear to your Electrician that all electrical work
must
conform to applicable local,
state, and federal codes, rules, and regulations, such as state and federal OSHA
regulations and electrical codes.
Your Lift was ordered with one of the following Power Units:
•
220 VAC, 60 Hz, 1 Phase
. 220 VAC, for North American countries (U.S., Mexico, Canada).
Could be Power Unit 5585280 or 5585181.
•
110 VAC
. 110 VAC, for North American countries (U.S., Mexico, Canada). Should be Power Unit
5585178.
•
220 VAC, 50/60 Hz, 1 Phase
. 220 VAC, for countries
outside
North America. Could be Power
Unit 5585182 or 5585247.
Power Units are provided by different vendors so there may be minor differences in look and feel.
However, all Power Units of the same type provide the same level of functionality.
All Power Units come with a ‘pigtail’ coming out of the Electrical Box. To connect your Power Unit to a
power source, remove the pigtail and connect the Electrical Box to the electrical system at your
location or to an appropriate power cord with plug.
Make clear to your Electrician that all electrical work
must
conform to applicable local, state and
federal codes, rules, and regulations, such as state and federal OSHA regulations and electrical codes.
⚠
DANGER
The following procedure
must
only be performed by a licensed, certified
Electrician.
To connect the Lift to a power source
:
1.
Locate the Pigtail coming out of the Electrical Box on the Power Unit.
2.
Open the Electrical Box,
remove the Pigtail
, and then either:
–
Wire the Power Unit directly into the facility’s electrical system.
–
Wire a power cord with appropriate plug
inside the Electrical box
where the Pigtail was wired.
Wiring information is either on the outside of the Power Unit under the Electrical Box or inside the
cover of the Electrical Box. Have the Electrician use that wiring information to wire the Power Unit
to the power source.
You can also find the Wiring Diagram for your Power Unit in
3.
Close the Electrical Box.
Summary of Contents for HD-7P
Page 8: ...HD 7P HD 7W Four Post Lifts 8 P N 5900041 Rev M July 2019 Specifications ...
Page 78: ...HD 7P HD 7W Four Post Lifts 78 P N 5900041 Rev M July 2019 5585182 5585247 ...
Page 79: ...HD 7P HD 7W Four Post Lifts 79 P N 5900041 Rev M July 2019 Labels ...
Page 80: ...HD 7P HD 7W Four Post Lifts 80 P N 5900041 Rev M July 2019 ...
Page 81: ...HD 7P HD 7W Four Post Lifts 81 P N 5900041 Rev M July 2019 ...
Page 82: ...HD 7P HD 7W Four Post Lifts 82 P N 5900041 Rev M July 2019 Parts Drawings ...
Page 83: ...HD 7P HD 7W Four Post Lifts 83 P N 5900041 Rev M July 2019 ...
Page 84: ...HD 7P HD 7W Four Post Lifts 84 P N 5900041 Rev M July 2019 ...
Page 85: ...HD 7P HD 7W Four Post Lifts 85 P N 5900041 Rev M July 2019 ...
Page 86: ...HD 7P HD 7W Four Post Lifts 86 P N 5900041 Rev M July 2019 ...
Page 87: ...HD 7P HD 7W Four Post Lifts 87 P N 5900041 Rev M July 2019 ...
Page 88: ...HD 7P HD 7W Four Post Lifts 88 P N 5900041 Rev M July 2019 ...
Page 89: ...HD 7P HD 7W Four Post Lifts 89 P N 5900041 Rev M July 2019 ...
Page 91: ...HD 7P HD 7W Four Post Lifts 91 P N 5900041 Rev M July 2019 Maintenance Log ...