Park the vehicle on level ground and chock wheels.  Build system pressure to governor cut-out 

and allow the pressure to stabilize for one minute.  

1: Observe the dash gauges for two additional minutes without the service brakes applied.  

2: Apply service brakes for two minutes (allow pressure to stabilize) and observe the dash 

gauges.   

If you see any noticeable decrease of the dash air gauge readings, repair leaks.  Repeat 

this test to confirm that air leaks have been repaired and return vehicle to service.  Please 

repeat BASIC

 test at next service interval.  Note: Air leaks can also be found in the charging 

system, parking brakes, and/or other components - inspect and repair as necessary.  

STEP E 

- If no air leakage was detected in Step D 

STEP D - Air Brake System Leakage Test 

STEP C 

- How to Use the BASIC

 Test

Sixty days since last air 

tank draining

Decision point

The Technician uses the chart (label) on the BASIC

 

test cup to help decide the action to take, based on 
the amount of oil found.  Use the lower acceptance 
line for low air use vehicles, and upper line for high 
air use vehicles (from Step A).

 

If no air leakage was detected, and if you are conducting 

this test after completing Step C, go to Step E.

BASIC

™ 

Test Example

An oil level of 4 units in a sixty-day period is within the 

acceptance area (at or below the line) for both low and 

high air use vehicles.  Return the vehicle to service.  

1.  Record days since air 

tanks were last drained.  

3.  Action to 

take  

2.  Record amount 

of oil found:  

If number of days is: 

30-60 days (high air 

use) or 

30-90 days (low air 

use) 

if oil level is 

at or below 

acceptance line for number

of days

if oil level is 

above 

acceptance line for number

of days 

System OK.
Return to service.

Otherwise .  .  .

(if the number of days is 

unknown, or outside the 

limits above)

if oil level is 

at or below 

30-day acceptance line 

if oil level is 

above 30-day 

acceptance line 

STOP

TEST

Stop inspection.

Test again 

after 30 days.

See Footnote 2.

_________ days

_________ units

Go to Step D

System OK.
Return to service.

STOP

TEST

STOP

+ CK.

The Technician looks for the point where the number of 
days since the air tanks were drained meets the oil level.  
If it is at or below the (low or high use) acceptance line, 
the vehicle has passed the test.  If the point is above 
the line then go to the leakage test.

Air leakage is the number one 
cause of compressors having 
to pump excessive amounts of 
air, in turn run too hot and pass 
oil vapor along into the system.  
Here the Technician conducts a 
four-minute test to see if leakage 
is a problem with the vehicle 
being tested.

The Technician only reaches 
Step E if  the amount of  oil 
found, or the amount of time 
since the air tanks were last 
drained exceeds the acceptance 
level, AND the vehicle passes 
the four-minute leakage test 
(no noticeable leakage was 
detected).

Replace the compressor.  

Note: If the compressor is within warranty period, 
please follow standard warranty procedures.  Attach 
the completed checklist to warranty claim.

Filling in the Checklist for the 

B

endix

®

 

A

ir 

S

ystem 

I

nspection 

C

up (BASIC

) Test

Note: Follow all standard safety precautions.  For vehicles using a desiccant air dryer.

Appendix B continued: Information about the BASIC

Test Kit (Bendix P/N 5013711)

Oil 

Level

X

Acceptance

Lines

Summary of Contents for SNA-01

Page 1: ...cylinder head contains air and water ports as well as an unloader assembly The discharge jumper is connected to the cylinder head and re routes the discharge air to the discharge port of the cylinder...

Page 2: ...e electrical system in a manner that safely removes all electrical power from the vehicle Never exceed manufacturer s recommended pressures Never connect or disconnect a hose or line containing pressu...

Page 3: ...rge Jumper Oil Supply Port Piston Assembly Special Fitting pre installed in coolant port Unloader Piston Sleeve Bearing Rear Cover Plate Special Fitting pre installed in inlet port FIGURE 5 CHARGING S...

Page 4: ...valve and is compressed as the piston moves upwards When air in the cylinder bore reaches a pressure greater than that of the system pressure the discharge reed valves open and allow air to flow into...

Page 5: ...bushings is obtained as oil is forced out around the crankshaft journals by engine oil pressure Oil then falls to the bottom of the compressor crankcase and is returned to the engine through drain hol...

Page 6: ...strictions to flow Minimum coolant line size is 3 8 Inside Diameter I D Check coolant lines for internal clogging from rust scale If coolant lines appear suspicious check the coolant flow and compare...

Page 7: ...pressor Performance Build up Test This test is performed with the vehicle parked and the engine operating at maximum recommended governed speed Fully charge the air system to governor cut out air drye...

Page 8: ...om Cover Gasket Cap Screws Plug Sleeve Bearing Plug Inlet Reed Valve Gasket Head Gasket Cylinder Head Valve Plate Assembly Piston Assembly Safety Valve Plug Discharge Jumper Washer Discharge Jumper Di...

Page 9: ...ity Description Cylinder Head Gasket Kit P N K023764 14 2 Head Gasket 17 1 Inlet Reed Valve Gasket Discharge Jumper Kit P N K092848 12 1 Bendix ST 4 Safety Valve 37 1 Discharge Jumper 38 4 Discharge J...

Page 10: ...et discharge and unloader piston leakage it may not be practical to do so Inlet and discharge valve leakage can generally be detected by longer compressor build up and recovery times Compare current c...

Page 11: ...intenance may only need to include portions of these instructions DISCHARGE JUMPER ASSEMBLY FITTINGS Note The discharge jumper 37 must be removed in order to remove the inlet fitting 35 and to service...

Page 12: ...ect both sides of the head gasket surfaces on the cooling plate 15 for deep gouges and nicks Also inspect the cooling plate for any cracks or other damage If found the compressor must be replaced 3 Ca...

Page 13: ...rn REAR COVER PLATE 1 Place the rear cover plate gasket 30 onto the rear cover plate 32 Note This should be the same surface that the old gasket was removed from 2 Place the gasketed side of the cover...

Page 14: ...of the port Light wrenching may be necessary To align the tube end to the position as defined in Figure 12 unscrew the fitting by the required amount but not more than one full turn Using two wrenche...

Page 15: ...equirements FIGURE 12 REQUIRED ORIENTATION OF THE INLET AND TOP COOLANT FITTINGS 2 Install any supporting brackets on the compressor in the same position s noted and marked during removal If a rear su...

Page 16: ...r to properly test a compressor under operating conditions a test rack for correct mounting cooling lubricating and driving the compressor is necessary Such tests are not compulsory if the unit has be...

Page 17: ...70 305 in lbs 30 5 34 5 N m M5x0 75 6g Unloader Cap 62 71 in lbs 7 8 N m M8x1 25 6h Discharge Jumper 115 133 in lbs 13 15 N m M8x1 25 6g Rear End Cover 195 213 in lbs 22 24 N m M6x1 00 6g Crankcase Co...

Page 18: ...18...

Page 19: ...urrounding area 3 0 A 5 In the supply reservoir 4 0 A 6 8 At the valves 5 0 A 8 At air dryer cartridge 7 0 A 9 In the ping tank or compressor discharge aftercooler 8 0 A 9 Symptom Page Number 1 Oil Le...

Page 20: ...h may require additional maintenance Factors that add to the duty cycle are air suspension additional air accessories use of an undersized compressor frequent stops excessive leakage from fittings con...

Page 21: ...onth Every 3 Years Every 2 Years Every Year I D Vehicle Used for Column 1 Column 2 Column 3 Column 4 Column 5 Regularly scheduled maintenance is the single most important factor in maintaining the air...

Page 22: ...and thoroughly understand the recommended procedures Use only the proper tools and observe all precautions pertaining to use of those tools If the work is being performed on the vehicle s air brake s...

Page 23: ...7 for the Bendix AD IS or AD IP air dryers or 5003838 for the Bendix AD 9 air dryer is available to redirect the air dryer exhaust 3 0 Oil at air dryer purge exhaust or surrounding area 2 0 Oil on the...

Page 24: ...oil found is within the acceptable level If within the normal range return the vehicle to service For vehicles with accessories that are sensitive to small amounts of oil consider a Bendix PuraGuard Q...

Page 25: ...inlet insulation may be added here or if the inlet fitting is a typical 90 fitting it may be changed to a straight or 45 fitting For more information on how to help prevent discharge line freeze ups s...

Page 26: ...lines tests all air brake system pneumatic components need to be able to pass including minimum levels of tolerance to contamination 5 0 Oil present at valves e g at exhaust or seen during servicing A...

Page 27: ...may be undersized for the application d Compressor unloader mechanism malfunction e Damaged compressor head gasket Using dash gauges verify that the compressor builds air system pressure from 85 100 p...

Page 28: ...rge line see Table A column 2 on page A 3 for recommended size and go to Test 3 on page A 14 By other restrictions e g kinks Replace the discharge line See Table A column 2 on page A 3 for recommended...

Page 29: ...y form and block the flow If instead ice blockages occur at the air dryer inlet insulation may be added here or if the inlet fitting is a typical 90 fitting it may be changed to a straight or 45 fitti...

Page 30: ...age A 15 Go to Test 2 on page A 14 Go to Test 5 on page A 15 12 0 Air dryer safety valve releases air a Restriction between air dryer and reservoir b Air dryer safety valve malfunction c Air dryer mai...

Page 31: ...31...

Page 32: ...ak at the head gasket may indicate a downstream restriction such as a freeze up or carbon blockage and or could indicate a defective or missing safety valve Find blockage go to 9 0 f for details and t...

Page 33: ...Test 2 Air Brake System and Accessory Leakage Caution The temperatures used in this test are not normal vehicle conditions Above normal temperatures can cause oil as vapor to pass through the air drye...

Page 34: ...to and from the governor for restrictions e g collapsed or kinked Repair as necessary 2 Using a calibrated external gauge in the supply reservoir service reservoir or reservoir port of the Bendix D 2...

Page 35: ...nk drain schedule for vehicles equipped with a Bendix air dryer that is properly maintained If in cold weather conditions the 30 day air tank drain schedule is longer than the customer s usual drainin...

Page 36: ...engine oil loss amount described _____________ Is the engine leaking oil no yes Is the compressor leaking oil no yes Other complaint __________________________________ No customer complaint Checklist...

Page 37: ...high air use or 30 90 days low air use if oil level is at or below acceptance line for number of days if oil level is above acceptance line for number of days System OK Return to service Otherwise if...

Page 38: ...The dryer inlet air temperature should typically be within the range of no more than 160 F and no less than 45 F above low ambient surrounding temperature to prevent freeze ups For example if low ambi...

Page 39: ...ate that using alcohol and alcohol based products sold for this purpose removes the lubrication from the components of the air braking system In addition the materials used for the internal seals of t...

Page 40: ...metallic parts of valves and melting or burning non metallic air lines WARNING THIS PRACTICE IS UNSAFE AND CAN RESULT IN VEHICLE FIRE 2 Do not introduce pour fluids into air brake lines or hose coupli...

Page 41: ...41 Log on and Learn from the Best On line training that s available when you are 24 7 365 Visit www brake school com SD 01 10142 2015 Bendix Commercial Vehicle Systems LLC All Rights Reserved 06 2015...

Reviews: