The 

RFID frequency is 13.56 MHz

. The PN532 Near Field Communication 

(NFC) controller is used for contactless communication, which supports virtu-
ally all RFID/NFC communication means on this frequency. Currently only pas-
sive tags with a UID are read. Further functionality is possible upon request.

2.1

Dimensions for mounting

All dimensions in mm

The RFID module is connected to the charge controller via a
standard RJ45 cable. 

10.00

38.00 

50.00 

92.50 

50.00 

85.00 

15.00 

3.10 

3.10 

3.10 

3.10 

Summary of Contents for RFID113

Page 1: ...Manual EN RFID113 For use in combination with charge controllers used in electric vehicle charging stations wall boxes and street light charging points RFID113_D00303_00_M_XXEN 05 2018 ...

Page 2: ...many Londorfer Strasse 65 35305 Grünberg Germany Tel 49 6401 807 0 Fax 49 6401 807 259 E Mail info bender de www bender de Bender GmbH Co KG All rights reserved Reprinting only with permission of the publisher Subject to change Photos Bender archives ...

Page 3: ...d support 5 1 3 Delivery conditions 6 1 4 Inspection transport and storage 6 1 5 Disposal 6 1 6 Intended use 6 2 RFID module 8 2 1 Dimensions for mounting 9 2 2 Operation 10 2 3 Integration 10 2 3 1 RJ45 connector pin assignment 11 3 Technical data 12 3 1 Tabular data 12 3 2 Standards approvals certifications 13 3 3 Ordering information 13 ...

Page 4: ......

Page 5: ...Questions concerning specific customer applications Commissioning Troubleshooting Telephone 49 6401 807 760 Fax 49 6401 807 259 In Germany only 0700BenderHelp Tel and Fax E mail support bender service de Available from 7 00 a m to 8 00 p m 365 days a year CET UTC 1 Thismanualisintended forqualifiedpersonnel workingin electrical engineering and electronics This symbol denotes information intended t...

Page 6: ...supplier if you are not sure how to dispose of the old equip ment For more information on the disposal of Bender devices refer to our homepage at www bender de Service support 1 6 Intended use This manual provides a description of an RFID module which can only be used in combination with the ICC1612 charge controller The charge controller is designed for use in electric vehicle EV charging station...

Page 7: ...ystem close to the reader on the RFID module Charging starts when the contactor in the charging system is switched on to provide power flow In offline operation the charge controller can optionally allow charging without authorization or it can authorize users based on RFID and a local white list of authorized RFID cards ...

Page 8: ... a distance of at least 20 mm from any significant metal surface or metal parts to ensure optimum RFID reading performance CAUTION Electrostatic discharge ESD can damage electronic compo nents Observe the precautions for handling electrostatically sensitive components in accordance with DIN EN 61340 5 1 and DIN EN 61340 5 2 Socket for RJ45 cable ...

Page 9: ...on which supports virtu ally all RFID NFC communication means on this frequency Currently only pas sive tags with a UID are read Further functionality is possible upon request 2 1 Dimensions for mounting All dimensions in mm The RFID module is connected to the charge controller via a standard RJ45 cable 10 00 38 00 50 00 92 50 50 00 85 00 15 00 3 10 3 10 3 10 3 10 ...

Page 10: ...FID card is again held in front of the charging system 2 3 Integration The RFID module is integrated solely in conjunction with ICC1612 charge con trollers under professional installation In most cases these charge controllers implement the functionality of an electric vehicle charging system in which the RFID module is used to authorize charging transactions The LEDM100 module is described in a s...

Page 11: ...11 RFID113_D00303_00_M_XXEN 05 2018 2 3 1 RJ45 connector pin assignment Pin number Description 1 N C 2 N C 3 GND 4 RX PN532 5 TX PN532 6 3 3 V 7 5 V not used for the RFID functionality 8 GND ...

Page 12: ...V Rated voltage tolerance 5 Rated current 70 mA Frequency Radio frequency 13 56 MHz Environment EMC EMC IEC61851 1 22 Operating temperature 30 70 C Climatic conditions acc to IEC 60721 Stationary use IEC 60721 3 3 3K5 except condensation water and formation of ice Transport IEC 60721 3 2 2K3 Long term storage IEC 60721 3 1 1K4 Mechanical conditions acc to IEC 60721 Stationary use IEC 60721 3 3 3M4...

Page 13: ...g certonal Protection class IP00 Maximum read distance 100 mm Weight 13 g 3 2 Standards approvals certifications The RFID module has been developed in compliance with ISO14443A MIFARE IEC 61851 1 22 IEC 60950 1 3 3 Ordering information Type Art No RFID113 B94060113 ...

Page 14: ...Technical data 14 RFID113_D00303_00_M_XXEN 05 2018 ...

Page 15: ......

Page 16: ...er GmbH Co KG P O Box 1161 35301 Gruenberg Germany Londorfer Strasse 65 35305 Gruenberg Germany Tel 49 6401 807 0 Fax 49 6401 807 259 E Mail info bender de www bender de Photos Bender archives BENDER Group ...