background image

LINETRAXX® CTUB103

Alle Rechte vorbehalten.
Nachdruck und Vervielfältigung
nur mit Genehmigung des Herausgebers.

Bender GmbH & Co. KG

Postfach 1161 • 35301 Grünberg • Deutschland
Londorfer Str. 65 • 35305 Grünberg • Deutschland
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: [email protected] • www.bender.de

All rights reserved.

Reprinting and duplicating

only with permission of the publisher.

Bender GmbH & Co. KG

PO Box 1161 • 35301 Grünberg • Germany

Londorfer Str. 65 • 35305 Grünberg • Germany

Tel.: +49 6401 807-0 • Fax: +49 6401 807-259

E-Mail: [email protected] • www.bender.de

CTUB103_D00410_02_M_XXEN / 09.2022

/ pdf / © B

ender G

mbH & C

o. K

G, G

erman

y – S

ubjec

t to change! 

The specified standar

ds tak

e in

to ac

coun

t the edition v

alid un

til 

09/2022

 

unless other

wise indic

at

ed

.

Summary of Contents for LINETRAXX CTUB103 Series

Page 1: ...Manual EN CTUB103_D00410_02_M_XXEN 09 2022 LINETRAXX CTUB103 AC DC sensitive measuring current transformer...

Page 2: ...al safety instructions Part of the device documentation in addition to this manual is the enclosed Important safety instructions for Bender products Mounting connection and commissioning are to be car...

Page 3: ...2 24 60 2 36 56 2 20 78 3 07 C CTUB103 CTBC120 188 7 40 225 8 86 96 3 78 120 4 72 65 2 56 96 3 78 139 5 47 D CTUB103 74 2 91 44 1 73 30 1 18 32 1 26 4 6 0 18 b c d a e d e f c b a d e f c b a g a d e...

Page 4: ...A 50 mA 100 1 10 A 10 A 50 mA 200 1 25 A 25 A 50 mA 500 1 1 11 10 9 2 3 4 5 6 7 8 Offset Calibration i For measuring current transformer cores with an internal diameter 120 mm an offset calibration sh...

Page 5: ...ce make sure that the installation has been de ener gised Observe the rules for working on electrical installations Observe the information on no minal voltage and supply voltage specified in the tech...

Page 6: ...the meas uring current transformer Never route an existing protective conductor through the measuring current transformer PE L1 L2 L3 N P1 K YE P2 L GY The primary conductors may only be bent from th...

Page 7: ...ue CTBC35 0 6 Nm CTBC60 CTBC120 1 Nm Other Operating mode continuous operation Mounting any position Degree of protection built in components DIN EN 60529 IP40 Degree of protection terminals DIN EN 60...