10
CC612(4G)_D00325_06_Q_DEEN / 06.2021
CC612 Laderegler/ CC612 charge controller
Anschlusseigenschaften:
Starr/flexibel .............................................0,2…1,5 mm² (AWG 24…16)
flexibel mit Aderendhülse ohne Kunststoffhülse. .....................................
................................................................0,25…1,5 mm² (AWG 24…16)
flexibel mit Aderendhülse mit Kunststoffhülse .........................................
..............................................................0,25…0,75 mm² (AWG 24…20)
Abisolierlänge ................................................................................ 10 mm
Öffnungskraft .......................................................................0,5…0,6 Nm
Anschlussart (Klemmenblöcke A und B) ..........................Schraubklemme
Anschlusseigenschaften:
Starr/flexibel .............................................0,2…2,5 mm² (AWG 24…12)
flexibel mit Aderendhülse ohne Kunststoffhülse ......................................
................................................................0,25…2,5 mm² (AWG 24…14)
flexibel mit Aderendhülse mit Kunststoffhülse .........................................
................................................................0,25…1,5 mm² (AWG 24…16)
Abisolierlänge .................................................................................. 7 mm
Sonstiges
Betriebsart ............................................................................Dauerbetrieb
Schutzart .............................................................................................IP20
Connection properties:
rigid/flexible .............................................0.2…1.5 mm² (AWG 24…16)
flexible with ferrule without plastic sleeve ...............................................
................................................................0.25…1.5 mm² (AWG 24…16)
flexible with ferrule with plastic sleeve. ...................................................
..............................................................0.25…0.75 mm² (AWG 24…20)
Stripping length ............................................................................. 10 mm
Opening force ..................................................................... 0.5…0.6 Nm
Connection type (terminal blocks A and B) ................screw-type terminal
Connection properties:
rigid/flexible .............................................0.2…2.5 mm² (AWG 24…12)
flexible with ferrule without plastic sleeve ...............................................
................................................................0.25…2.5 mm² (AWG 24…14)
flexible with ferrule with plastic sleeve ....................................................
................................................................0.25…1.5 mm² (AWG 24…16)
Stripping length ............................................................................... 7 mm
Other
Operating mode ...................................................... continuous operation
Degree of protection ...........................................................................IP20