![Benchmark RD 532i Installation And Servicing Instructions Download Page 30](http://html1.mh-extra.com/html/benchmark/rd-532i/rd-532i_installation-and-servicing-instructions_2731319030.webp)
6 720 611 449 GB (03.11)
30
Text Display
6.5.2
Setting the Economy temperature (if TR2
is connected)
This option allows you to set the room temperature for
Economy mode (Off (Economy))
.
This function is only active if:
• Automatic mode or Economy mode is set on the TR
2 room thermostat.
B
From the main menu, select
Heating
and then from
the first submenu, select
Set Economy temp.
.
B
Use the
or
button to set a temperature
between 5 and 30 °C.
6.5.3
Manual operating mode (if TR2 is not con-
nected)
For selecting an operating mode that is different from
the one set in the heating programme (
Automatic
mode
).
• You can choose between
Automatic
,
Constant on
(comfort)
and
Constant off (economy)
.
• The manually selected operating mode starts imme-
diately.
• Constant off (economy) and Constant on (comfort)
are automatically reset at 00.00 (midnight).
• To cancel the manually selected operating mode:
– select the relevant menu and then press the
button,
– or select a different operating mode,
– or set
Holiday
.
B
From the main menu select
Heating
and then from
the first submenu
Manual
select required mode.
6.6
Hot water
General description
•
ZSBR models (with Storage Tank)
: The basic
settings provide a timer programme: enable from
5:00 am, disable from 10:00 pm. With the menu
Hot
water
(see page 31) you can choose a timer-/tem-
perature programme with the basic settings: 60 °C
from 5:00 am, 10 °C from 10:00 pm.
6.6.1
Hot water programme
• Up to six switching points per day can be set.
• There are two operating modes: Blocked and
Released.
B
From the main menu, select
Hot water
and then
from the first submenu, select
Hot water program
.
B
Set the days of the week, Blocked/Released (operat-
ing mode) in the same way as for the switching points
and modes for heating as described on page 29.
6.6.2
Hot water immediately
•
Hot water immediately ON
:
– Comfort mode is active for 2 hours.
•
Comfort mode is active for 2 hours
: normal auto-
matic program (Hot water mode according to timer
programme entered).
B
From the main menu, select
Hot water
and then
from the first submenu, select
Hot water immedi-
ately
.
B
Press
or
to switch
Hot water immedi-
ately
on or off.
6.7
i Info
B
Select
Info
from the main menu.
You can view the following information:
C
Display text
Description
Room temperature
(if TR 2 connected)
Current temperature in the
room where TR 2 is installed
Required room tem-
perature
(if TR 2 connected)
Required temperature in room
where TR 2 is installed
Operating mode
(if TR 2 connected)
E. g. Heating, Economy in Auto-
matic mode
or
Economy, Heating, Frost pro-
tection in manual mode
Max. flow temp.
Maximum CH flow temperature
set on the temperature control
for CH flow
Actual flow temp.
Actual CH flow temperature
Required flow temp.
Required CH flow temperature
Max HW temp.
Maximum permissible hot water
outflow temperature
Required HW temp.
Required hot water tempera-
ture
Actual HW temp.
Actual hot water outflow tem-
perature
Storage Tank
charge released or
blocked
Shows, if hot water is released
or blocked
Storage Tank
charge on or off or
Storage Tank
charge afterrunning
Shows, if hot water is on or off,
or if the pump for the Storage
Tank afterrunning is on
Boiler operat. mode
winter
/
summer
Indicates which mode the CH
flow temperature control is set
to
Burner on/off
Indicates whether the burner is
alight or not
Pump on/off
Indicates whether the integral
pump is switched on or off