Page 5
BOILERMA
TE
A-CL
ASS
OV
1.2 TECHNICAL DATA
Notes:-
1. The BoilerMate 225 appliance is suitable for use in large properties because it produces the same ‘peak hour output’ as a typical 350-
400 litre unvented cylinder. For properties requiring the BMA 225 the incoming main should be a minimum of 32mm MDPE with
a pressure of not less than 2 bar dynamic and an adequate fl ow in line with the pipe sizing calculations. In many cases, properties
of this size will benefi t from having 2 smaller sized appliances located adjacent to the areas of peak hot water use. This will allow
2 heating zones to be provided and remove the need to provide trace heating on the hot water system.
2. A plastic feed and expansion cistern will be supplied separately including ballvalve, fl oat and overfl ow fi tting.
3. The fl ow rates are based on a 35°C temperature rise and assume normal pressure and adequate fl ow to the appliance. The actual
fl ow rate from the appliance is automatically regulated to a maximum of 28 litres/min.
4. Unit is supplied on a 100mm high installation base.
5. The domestic hot water outlet temperature is automatically regulated to approximately 52°C at the bath fl ow rate of 18 litres/min
recommended by BS 6700. The temperature is not user adjustable.
1.0 DESIGN
Model
BMA 125 OV
BMA 145 OV
BMA 185 OV
BMA 215 OV
BMA 225 OV
Weight (empty)
45
47
50
51
56
Weight (full)
177
187
197
215
244
DHW Pump
Grundfos UPR 15/50
Grundfos UPR 15/50
Grundfos UPR 15/50
Grundfos UPR 15/50
Grundfos UPR 15/50
Heating Pump
Grundfos UPS 15/50
Grundfos UPS 15/50
Grundfos UPS 15/50
Grundfos UPS 15/60
Grundfos UPS 15/60
Boiler Pump
Grundfos UPR 15/50
Grundfos UPR 15/50
Grundfos UPR 15/50
Grundfos UPR 15/60
Grundfos UPR 15/60
Primary/heating
pipe connections
22mm
22mm
22mm
28mm
28mm
MCW & DHW pipe
connections
22mm
22mm
22mm
22mm
22mm
Cold feed/expansion
connection
22mm
22mm
22mm
22mm
22mm
Safety open vent
connection
22mm
22mm
22mm
22mm
22mm
Primary return
(for summer use
bathroom towel rail)
15mm
15mm
15mm
15mm
15mm
Maximum summer
towel rail load
0.15kW
0.75kW
1.00kW
1.25 kW
1.5 kW
Drain connection
R ½”
R ½”
R ½”
R ½”
R ½”
Maximum Head
6 meters
6 meters
6 meters
6 meters
6 meters
Hot water fl ow rate
(l/m) up to
35
35
35
35
35
Max heating system
size
12 kW
17 kW
20 kW
25 kW
30 kW
‘Switch’
6 kW
6 kW
6 kW
6 kW
6 kW
Typical Dwelling Types
Bedrooms
1-3
2-3
2-4
3-5
4-6
Bathrooms
1
1
2
1 2
1 2
En-suite shower
1
2
1
4 2
4 3
Summary of Contents for BoilerMate BMA 125 OV
Page 45: ......