![BEMKO PSF-ST72-MG Instructions Download Page 4](http://html.mh-extra.com/html/bemko/psf-st72-mg/psf-st72-mg_instructions_2731104004.webp)
stopped working within 5-15sec.
Turn LUX knob anti-clockwise on the minimum. If it is adjusted in the less than 3LUX, the
inductor load should not work after load stop working. Under no induction signal condition,
the load should stop working within 5-15sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor light could not work!
NOTES:
Electrician or experienced human can install it.
The unrest objects can’t be regarded the installation basis-face.
In front of the detection window there shouldn’t be hinder or unrest objects effecting
detection.
Avoid installing it near air temperature alteration zones for example: air condition, central
heating, etc.
For your safety. Please don’t open the case if you find hitch after installation.
In order to avoid the unexpected damage of product, please add a safe device of 6A when
installing infrared sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light does not turn on after sensing, please check if the working light
corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check if in front of the detection window there are hinder that effect to
receive the signals.
b. Please check the ambient temperature.
c. Please check if the signals source is in the detection fields.
d. Please check the installation height.
The sensor can’t shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power correspond to the instruction.
d. If the air temperature change near the sensor, air condition or central heating etc.
TECHNISCHE DATEN:
Leistung: max. 60 W E 27
Netzanschluss: 230 – 240 V, 50 Hz
Einsatzort: im Innenbereich von Gebäuden, Wand-/Deckenmontage
HF-Technik: 5,8 GHz
Sendeleistung: ca. 10 mW
Erfassung: 360°, 160° Öffnungswinkel ggf. durch Gla s, Holz und Leichtbauwände
Reichweite: Ø 1 – 8 m, stufenlos einstellbar
Zeiteinstellung: 5 Sek. bis 12 Min.
Dämmerungseinstellung: 3 – 2000 Lux
Schutzart: IP 20
Eigenverbrauch: ca. 0,9 W
Temperaturbereich: -10 °C bis +50 °C
Funktionen:
Die Sensor Leuchte ist ein aktiver Bewegungsmelder. Der integrierte HF-Sensor sendet
hochfrequente elektromagnetische Wellen (5,8 GHz) aus und empfängt deren Echo. Bei der
kleinsten Bewegung im Erfassungsbereich der Leuchte, wird die Echoveränderung vom Sensor
wahr genommen. Ein Microprozessor löst dann den Schaltbefehl „Licht einschalten“
aus. Eine Erfassung durch Türen, Glasscheiben oder dünne Wände ist möglich.
Hinweis: Die Hochfrequenzleistung des HF-Sensor
beträgt
ca.10Mw-das
ist
nur
ein
100stel
der
sendeleistung eine Handys oder Microwelle
Installation:
Bei der Montage der Sensor Leuchte ist darauf zu achten, dass sie erschütterungsfrei befestigt
wird