28
29
TROUBLESHOOTING GUIDE (CONT.)
SPECIFICATIONS
Item
LW-1000
Rated Voltage
AC 120V, 60Hz
Max. Power Consumption
870W
Power cord length
1.2m
Water feed method
Directly connects to water pipe
Recommended inlet water pressure 99~106.6 psi
Wash
Feed
Volume
Wash
0.13~0.21 gal/min
Bidet
0.13~0.18 gal/min
Turbo
0.13~0.18 gal/min
Child
0.13~0.16 gal/min
Pressure control
5 Levels
Temperature Control
4 Levels (off - low - middle - high)
Heater capacity
800W
Safety device
Water level sensor, Thermal fuse,
Bi-metal, temperature sensor
Heated
Seat
Temperature control
4 levels (off - low- middle - high)
Heater capacity
55W
Safety device
Thermal fuse
Dry
Temperature control
Room temp. ~ 122°F
Heater capacity
250W
Safety device
Thermal fuse, Bi-metal
Feed water temp. tolerance range
37 ~ 95°F (recommended 54 ~ 95°F)
Usage room temp. tolerance range 37 ~ 104°F (recommended 50 ~ 95°F)
Dimension Elongated
18.6” (470) x 20.8” (528) x 7.0” (178)
Round
18.6” (470) x 19.5” (496) x 7.0” (178)
Weight
Net
weight
(Gross
weight)
Elongated
17.4 lb (17.4)
Round
17.1 lb (17.2)
Please check the following table and inform the exact status
when requesting repair service.
No.
Self Diagnosis
Indication
1
Water temp sensor is
disconnected or not inserted
LEDs of water low + middle
level blinking
2
Water temp sensor is short-
circuited or overheated
LEDs of water high + middle
level blinking
3
Seat temp sensor is
disconnected or not inserted
LEDs of water low level blinking
4
Seat temp sensor is short-
circuited or overheated
LED of water high level blinking
Summary of Contents for Bio Bidet LW-1000
Page 1: ...OWNER S MANUAL LW 1000 ...