background image

General warnings

This section contains important information about safety, handling and operating 

conditions. Keep this booklet for future use. If you are just installing the device, this 

booklet must be given to the householder. 

 

Hazard warnings

 

Failure to follow these safety instructions could result in fire, electric shock, or other 

injury or damage to the device or other property.

 

The wrist receiver and charger can only be used with rechargeable NiMH batteries! 

Non-rechargeable batteries will start to leak if recharged! The acid in the batteries will 

damage the electronics in the wrist receiver and the charger. The resulting damage will 

not be covered by any guarantee. 

Only use Varta V40H batteries for the wrist receiver 

and Lexel 600AAA batteries for the charger.

 

Be aware that alarms and notifications can be missed if batteries run out. 

 

Keep this device out of reach of children under 3 years.

 

Batteries are toxic. Do not swallow them! Keep out of reach of children and pets. If they 

are swallowed, consult your physician immediately!

 

Do not use or store this device near any heat sources such as naked flames, radiators, 

ovens or other devices that produce heat.

 

Use only power adapters and battery types that are specified in this leaflet. 

 

Protect cables from any potential source of damage.

 

This device is designed for indoor use only. Do not expose the device to moisture.

 

Protect the device from shocks during storage and transport.

 

Do not make any changes or modifications to this device. Use only original Bellman & 

Symfon accessories to avoid any electrical shock.

 

Information on product safety

 

Failure to follow these instructions could result in damage to the device and void the 

warranty. 

 

Do not expose batteries to fire or to direct sunlight. 

 

Rechargeable batteries should be charged fully before using the device for the first 

time. Only charge batteries in a temperature between 0°– 35°C, 32°– 95° F.

 

If a serious incident occurs in relation to this device, contact the manufacturer and 

relevant authority. 

 

Do not drop your device. Dropping onto a hard surface can damage it.

 

The device may only be repaired by an authorized service center.

 

If you encounter other problems with your device, contact the point of purchase, your 

Compatible Visit transmitters

 

BE1411 Visit door transmitter

 

BE1420 Visit pushbutton transmitter

 

BE1431 Visit telephone transmitter

 

BE1432 Visit mobile phone transmitter

 

BE1481 Visit smoke alarm transmitter

 

BE1551 Visit smoke alarm transmitter

 

BE1555 Visit CO alarm transmitter

 

BE1491 Visit baby monitor

Available accessories

 

BE1270 Bed shaker 

For detailed product information, see the corresponding user manual.

Operating conditions

Operate the device in a dry environment within the temperature and humidity limits 

stated in this leaflet. If the device gets wet or is exposed to moisture, it should no longer 

be regarded as reliable and should therefore be replaced. 

Cleaning

Disconnect all cables before you clean your device. Use a soft, lint-free cloth. Avoid 

getting moisture in openings. Do not use household cleaners, aerosol sprays, solvents, 

alcohol, ammonia or abrasives. This device does not require sterilization.

Service and support

If the device appears to be damaged or doesn’t function properly, follow the instructions 

local Bellman & Symfon office or the manufacturer. Visit 

bellman.com

 for contact info.

 

Do not use the device in areas where electronic equipment is prohibited. 

 

Without permission granted by the NCC, no company, enterprise or user is allowed to 

change the frequency, enhance the transmitting power or alter the original character-

istics or performance on an approved low power radio frequency device. 

 

This device should not be used on aircrafts unless specifically permitted by flight personnel.

 

The wrist receiver will not vibrate when it’s in the charger. A bed shaker must be con-

nected to the charger to provide a vibratory alert. Other indicators will act as normal. 

Apart from a bed shaker, it is also possible to connect other products such as some 

Bellman & Symfon alarm clock models to the vibrator output.

Configuration options

The BE1560 wrist receiver can be configured with the following Visit transmitters and 

original accessories:

Summary of Contents for BE8102

Page 1: ...BE8102 Visit wrist receiver...

Page 2: ...sit wrist receiver FR FI ES EN DK NO NL DE SE 3 Bedienungsanleitung 7 Brugervejledning 11 User manual 15 Manual de usuario 19 K ytt opas 23 Mode d emploi 27 Gebruiksaanwijzing 31 Brukermanual 35 Bruks...

Page 3: ...e Visit receiver that alerts the user with sound flashes or vibrations In order to use the system you need at least one transmitter and one receiver Getting started 1 Pull the battery tab on the charg...

Page 4: ...reen and yellow Visit LEDs 1 blink alternately Release the button 3 Press the test button s on the transmitter within 30 seconds to send the new radio key 4 All Visit LEDs 1 on the wrist receiver blin...

Page 5: ...evant authority Do not drop your device Dropping onto a hard surface can damage it The device may only be repaired by an authorized service center If you encounter other problems with your device cont...

Page 6: ...te Electrical Electronic Equipment WEEE EC Battery Directive in the user guide and this leaflet If the product still doesn t function as intended contact your local hearing care professional for infor...

Page 7: ...as well as the Radio Equipment Directive 2014 53 EU This symbol indicates that the product shall not be treated as household waste Please hand over your old or unused product to the applicable collect...

Page 8: ...e of issue 2022 02 18 TM and 2022 Bellman Symfon AB All rights reserved Manufacturer Bellman Symfon Group AB S dra L ngebergsgatan 30 436 32 Askim Sweden Phone 46 31 68 28 20 E mail info bellman com b...

Reviews: