7
Electrlcal connection
This appliance must be
installed by a qualified person.
Before connecting the appliance, make sure that
the supply voltage marked on the rating plate
corresponds with your mains supply voltage.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
• This appliance must be wired into a double
pole switched fused spur outlet, having 3 mm
contact separation and placed in an easily
accessible position adjacent to the appliance.
It should not be located above the appliance
and no more than 1.25m away from it.
• The spur outlet must still be accessible even
when your cooker is located in its operating
position.
Connecting the mains supply cable
• The mains terminal block is located on the
underside of the hob and the terminals are
accessible by removing the terminal block
cover by removing the cover screw.
• The cable connections must be in accordance
with the diagram located on the bottom of the
hob.
Replacing the mains supply cable
If the mains supply cable is damaged, then it
must be replaced by an appropriate replacement.
The mains supply cable should be replaced in
accordance with the following instructions:
• Switch the appliance off at the control switch.
• Open the terminal block on the underside of
the hob.
• Unscrew the terminal screws fixing the cable.
• Replace the cable with one of the same length
and in accordance with the specification given
above.
Fig. B
Fig. C (rear view)
Fig. D
Fig. E
(A) Sealing strip
(B) Clamp
(C) Screw