7
Cut-out dimensions
CAUTION!
Your appliance must be mounted on a flat surface for the full width and depth of the product.
Connect power supply
WARNING: THIS APPLIANCE MUST BE EARTHED.
z
This appliance should be wired into a 30A double pole switched fused spur outlet, having 3 mm contact
separation and placed in an easily accessible position adjacent to the appliance. The spur outlet must still
be accessible even when your oven is located in its housing to enable the appliance to be disconnected
from the mains supply.
z
To connect the oven power cord, loosen and remove the cover on the terminal block, in order to gain access
to the contacts inside. Make the connection, securing the cord in place with the cable clamp provided and
then immediately close the terminal block cover again.
z
If you have to change the oven power cord, the earth (yellow/green) conductor must always be 10 mm
longer than the line conductors.
z
Care must be taken to ensure that the temperature of the mains supply cable does not exceed 50°C.
z
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement which can be
obtained from the Spares Department.
z
Cable type: H05 VV-F 3 core x 2.5 mm² or H05 VV-F 4 core x 2.5 mm²
Mounting Screw