7
2. Electrical connection.
Important:
the domestic wiring system is suitable for the power drawn by the hob.
the voltage corresponds to the value given in the rating plate
the power supply cable sections can withstand the load specified on the rating plate.
To connect the hob to the mains power supply, do not use adapters, reducers, or branching devices, as they
can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its temperature will not
exceed 75˚C at any point.
Check with an electrician whether the domestic wiring system is suitable without alterations. Any alterations
must only be made by a qualified electrician.
If the cable is damaged or to be replaced, the operation must be carried out the by after-sale agent with
dedicated tools to avoid any accidents.
If the appliance is being connected directly to the mains an omnipolar circuit-breaker must be installed with
a minimum opening of 3mm between contacts.
The installer must ensure that the correct electrical connection has been made and that it is compliant with
safety regulations.
The cable must not be bent, kinked or compressed.
The cable must be checked regularly and replaced by authorised technicians only.
Step 1: Undo screws, open terminal board cover at rear panel of appliance, make connection as per below
Step 2: close the cover and complete electrical connection.
3. Finally fix the appliance
1.
Place the hob face down on a table.
2.
Remove the protective layer.
3.
Place the hob in the hole made in the cupboard,
4.
pressing it firmly in so that it is closed off by the seal.
GSM Retail Australia
Pty Ltd ABN: 53 007 582 475
For Warranty and technical queries: 1300 373 199
Aust OR 0508123108 NZ
www.belliniappliances.com.au
Model: BDC302TG Fineline: 5103057 30cm Built In Ceramic Cooktop
B
lu
e
B
ro
w
n
Y
ellow / Green
Hard Wired Appliances :
When making the mains supply conductor connections to the terminal block within the terminal box , please ensure
that minimum clearances are being maintained between individual conductors and conductors/connectors to the
adjacent metal surfaces of the terminal box itself , where possible add heat shrink sleeves to any bare conductor end/
connectors prior to securing.