Data badge -
Lower part of front frame
Type of gas
This cooker must only be used with Natural
Gas only, as specified on the appliance
data badge.
Gas category
Natural Gas -
I
2H
Pressure setting
G20 Natural Gas @ 20 mbar
Pressure test point
Use the oven injector
Aeration
Fixed
Grill -
Grill burner is surface combustion
type. Spark gaps 3 - 4mm.
Hob -
Burners have burner heads and
caps which are removable for cleaning.
Concealed electrodes to each burner.
Ovens -
Oven burners are sheet steel,
with pierced ports in stainless steel flame
strip.
Spark Gap:
3 - 4mm.
Flame super -
vision
: Expansion type.
Thermostat phial
:
Front centre of oven roof.
Electrical supply
220 - 240V ~ 50Hz
Spark generator:
Mains operated 7 outlet
controlled by a single push button switch at the
left hand side of the facia to individual
electrodes.
Warning:
This cooker must be earthed.
Appliance class
Class 1, Freestanding
Countries of destination
GB - Great Britain, IE - Ireland
25
Gas
Burner
Nominal
Injector
Grammes per hour
Rate Qn
Size
Butane
Propane
Natural
Grill
2.4kW
115
-
-
Gas
Hob - LHF
1.0kW
77
-
-
Hob - LHR & RHR
2.0kW
104
-
-
Hob - RHF
3.0kW
130
-
-
Main Oven
2.5kW
180 Amal
-
-
Top Oven
1.75kW
110 Amal
-
-
Maximum heat input
Qn 12.9kW
-
-
-