26
English
Installation instructions
1.6.2 Item descriptions for fi gures 4 t/m 14
FIG. NO.
DESCRIPTION
1
Gas fi re; Concentric
fl ue
connection Ø130/Ø200 mm or Ø100/Ø150 mm
2
-
3
-
4
Restriction plate (The different sizes restriction plates are supplied with every appliance)
5
Chimney, min. Ø150 mm internal, totally gas tight.
6
Chimney or fi reproof sleeving. Min. Ø160 mm internal.
7
Ø100 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI.
8
Ø150 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI.
9
-
• The room-sealed gas appliances have been approved in
combination with the components of the concentric fl ue systems
listed in the instruction book: ‘AVAILABLE COMPONENTS
CONCENTRIC FLUE-SYSTEMS FOR BELLFIRES GAS FIRES
WITH CLOSED COMBUSTION SYSTEM’, according to the
European CE norm for gas appliances and may therefore be used
only
with these components.
•
The components of the concentric fl ue system of
:
* Bellfi res
- Muelink & Grol System
* Poujoulat
- DUOGAS System
* Ontop
- Metaloterm US System
* Jeremias/STB - H-Twin System (STB = Schoorsteen Techniek
Brummen NL)
* Jeremias
- TWIN-GAS System
may
not
be used together in one installation.
•
Check whether the wall or roof termination kit to be used
exactly
matches one of those listed in the above mentioned instruction book.
For the suitable and available components for concentric
chimney systems, please consult the instruction book:
“AVAILABLE COMPONENTS CONCENTRIC FLUE-SYSTEMS
FOR BELLFIRES GAS FIRES WITH CLOSED COMBUSTION
SYSTEM”
1.6.3 Gas connection
Operation (gas regulating block (and receiver))
outside
the appliance
(in the operating unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2” and a shut-off valve.