3.1
POSSIBLE REASONS
Possible reasons for the gas ! re going out are:
The concentric " ue system is not installed according to one of the methods detailed
in Paragraph 1.6.
An incorrect " ue gas restriction plate is ! tted.
The pilot light extinguishes if fumes are not exhausted or are insuf! ciently
exhausted.
The pilot light is either dirty or defective.
Insuf! cient gas pressure.
(Internal) leak of the concentric " ue system.
Thermocouple voltage is too low. This is usually caused by insuf! cient heating of the
thermocouple by the pilot light.
Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
Batteries in receiver or remote control are " at.
3.2
SAFETY MEASURES IN THE APPLIANCE
3.2.1 Thermo-electric pilot light shut off
The appliance is protected by means of a thermo-electric pilot light shut off in the event
of a gas escape from the main burner.
3.2.2 Over pressure safety system
The appliance is ! tted with a patented safety system, whereby the door will extract any
over-pressure that arises in a controlled way. In this, a spring system brie" y causes the
door to hinge forward a few centimetres. A loud noise can occur.
A safety strip limits the maximum degree to which the door can be tilted.
This applies to both doors#
If an over-pressure situation occurs, the appliance should be thoroughly checked by the
installer.
Summary of Contents for Tunnel 3
Page 2: ......
Page 4: ...4 Bell res English Instructions for use...
Page 6: ...6 Bell res English Instructions for use...
Page 8: ...8 Bell res English Instructions for use...
Page 22: ...22 Bell res English Instructions for use...
Page 23: ......
Page 26: ......
Page 28: ...4 Bell res English Installation instructions...
Page 30: ...6 Bell res English Installation instructions...
Page 106: ...82 Bell res English Installation instructions OPERATING UNIT...