FAULTS
POSSIBLE REASONS
Possible reasons for the gas fi re going out are:
• The concentric fl ue system is not installed according to one of the methods detailed
in Vent Installation.
• An incorrect “fl ue gas restriction plate” is fi tted.
• The pilot light extinguishes if fumes are not exhausted or are insuffi ciently exhausted.
• The pilot light is either dirty or defective.
• Insuffi cient gas pressure.
• (Internal) leak of the concentric fl ue system.
• Thermocouple voltage is too low. This is usually caused by insuffi cient heating of the
thermocouple by the pilot light.
• Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
• Batteries in receiver or remote control are fl at.
SAFETY MEASURES IN THE APPLIANCE
Thermo-electric pilot light shut off
The appliance is protected by means of a thermo-electric pilot light shut off in the event
of a gas escape from the main burner.
Over pressure safety system
The appliance is equipped with a safety system, whereby hatches will extract any over-
pressure that arises in a controlled way. In this, the hatches in the ceiling of the
combustion chamber, briefly open. A loud noise can occur.
A safety bracket limits the maximum opening of the hatches.
If an over-pressure situation occurs, the appliance should be thoroughly checked by the
installer.
Summary of Contents for Room Divider Large 3
Page 2: ......
Page 4: ...4 Bell res Installation instructions...
Page 70: ...70 Bell res Installation instructions DIMENSIONS ROOM DIVIDER LARGE 3 Hidden Door 10 cm frame...
Page 71: ...71 Bell res Installation instructions DIMENSIONS ROOM DIVIDER LARGE 3 Wall mounted 10 cm frame...
Page 72: ...72 Bell res Installation instructions OPERATING UNIT Dimensions in inches 9 7 12 4 11 3 2 14...