• All leak test should be performs outdoors.
• Extinguish all open flames before testing
• DO NOT smoke when perform leak test.
• DO NOT use the heater until all connections have been tested and do not leak.
⚠
WARNING
OPERATION INSTRUCTION
Leak Check
1. Make 2-3 oz of leak check solution (1 part liquid dish washing detergent and 3 pars water).
2. Apply several drops of solution to the connection between the hose and regulator.
3. Apply several drops of solution to the connection between regulator and the cylinder.
4. Make sure all patio heater and light valves are OFF.
5. Turn cylinder valve ON.
1. Turn cylinder valve OFF.
2. If there is a leak, disconnect the connection and reconnect, then perform another leak test.
If bubbles continue to appear after several attempts, you should replace the hose or cylinder
valve.
If NO bubbles appear, the connection is secure.
NOTE: You must perform a complete leak test whenever gas connections are loosened or
removed.
If bubbles appear at any connection, there is a leak.