background image

19

Vibratronic High Frequency Converter

Belle Group reserves the right to alter details and specifi

 cation without notice

 1 

972/99901 

972/99937 

972/99948 

Vibrator 

Head 

1

 2 

972/99902 

972/99938 

972/99949 

Eccenter 

Tube 

1

 3 

972/99903 

972/99939 

972/99950 

Rotor 

1

 4 

972/99904 

972/99940 

972/99951 

Bearing 

 

2

 5 

972/99905 

972/99941 

972/99952 

Bearing 

Tube 

1

 6 

972/99906 

972/99942 

972/99953 

Bearing 

Plate 

1

 7 

972/99907 

972/99943 

972/99954 

Skirted 

Nut 

1

 9 

972/99908 

972/99944 

972/99955 

Distance 

Tube 

2

 10 

972/99909 972/99945 

972/99956 

Stator 

1

 

11 

972/99910 

972/99910 

972/99910 

Silicone Hose 5mm 

1m

 13 

972/99911 972/99946 

972/99957 

Hose 

Nipple 

1

 

14 

972/99912 

972/99912 

972/99912 

Cable Gland EMV PG13 

1

 15 

972/99913 972/99913 

972/99913 

Connection 

3

 

16 

972/99914 

972/99914 

972/99914 

Silicone Hose 10mm 

1m

 17 

972/99915 972/99915 

972/99915 

Cable 

6mm 

6m

 

18 

972/99916 

972/99916 

972/99916 

Steel Bandage 206 

1

 19 

972/99917 972/99947 

972/99947 

Hose 

5m

 

20 

972/99919 

972/99919 

972/99919 

Steel Bandage 245 

1

 

22 

972/99920 

972/99920 

972/99920 

Switch Box Bottom - 110v 

1

 

22 

972/99963 

972/99963 

972/99963 

Switch Box Bottom - 230v 

1

 23 

972/99921 972/99921 

972/99921 

Cover 

1

 24 

972/99922 972/99922 

972/99922 

Gasket 

Rubber 

1

 25 

972/99923 972/99923 

972/99923 

Switch 

Cover 

1

 26 

972/99924 972/99924 

972/99924 

Switch 

Holder 

1

 27 

972/99925 972/99925 

972/99925 

Cable 

Clamp 

1

 

28 

972/99926 

972/99926 

972/99926 

Screws - Switch 

2

 

29 

972/99927 

972/99927 

972/99927 

Screws - Switch Holder 

2

 

30 

972/99928 

972/99928 

972/99928 

Screws - Cover 

4

 

31 

972/99929 

972/99929 

972/99929 

Screws - Cable Clamp 

2

 32 

972/99930 972/99930 

972/99930 

Cable 

Gland 

1

 

33 

972/99918 

972/99918 

972/99918 

Cable Gland EMV PG9 

1

 34 

972/99931 972/99931 

972/99931 

Switch 

1

 

35 

972/99958 

972/99958 

972/99958 

Steel Bandage 202 

1

 36 

972/99933 972/99933 

972/99933 

Cable 

10m

 

37 

972/99932 

972/99932 

972/99932 

Plug - 3 Pin 110v 

1

 

37 

972/99961 

972/99961 

972/99961 

Plug - 3 Pin 230v 

1

 

37 

972/99962 

972/99962 

972/99962 

Plug - 16amp 2 Pin Schuko 

1

 

38 

972/99936 

972/99936 

972/99936 

Cable Connection Plug 

3

 

39 

972/99935 

972/99935 

972/99935 

Cable Connection Box 

3

 40 

972/99934 972/99934 

972/99934 

Cable 

Protection 

1

 

 - 

972/00100 

972/00100 

972/00100 

Switch Box Comp. - 110v (Inclu. Items 22 - 33)  1

 

972/00200 

972/00200 

972/00200 

Switch Box Comp. - 230v (Inclu. Items 22 - 33)  1

 Not 

Shown 

  

972/99959 

Connecting 

Dome 

1

  

972/99960 

Circlip 

 

 ITEM 

  PART 

NUMBER

(2)

 

 

 

(4)

 NUMBER

(1)

 35 

51 

57 

DESCRIPTION

(3)

QTY

Summary of Contents for VIBRATRONIC

Page 1: ...1 870 20013 1 Spare Parts Book Bruksanvisning Operators Manual Betjene Håndbok GB NO 4 11 18 ...

Page 2: ...ad de Maquinaria y Niveles armonizados estándares asociados donde sean aplicables Emisión de Ruídos conforme a la Directiva 2000 14 CE Anexo VI para máquinas bajo artículo 12 la mencionada unidad está AV Technology Limited AVTECH House Birdhall Lane Cheadle Heath Stockport Cheshire SK3 OXU GB En La Sede Central de Belle Group existen Archivos Técnicos con contenido referente a Niveles de Ruido O s...

Page 3: ...finns dokumenterad hos Belle Groups huvudkontor i Sheen England Vi Belle Group Sheen UK Sheen Nr Buxton Derbyshire SK17 0EU GB bekrefter med dette at det produktet som står beskrevet i denne erklæringen er kjøpt fra en autorisert Belle Group forhandler innen EØF og at det oppfyller følgende direktiver 98 37 CE dette direktivet er et sammendrag av det opprinnelige maskindirektivet 89 392 EØF Det el...

Page 4: ...equency Poker Foreword The Machine Description section helps you to familiarise yourself with the machine s layout and controls The General Safety and Health and Safety sections explain how to use the machine to ensure your safety and the safety of the general public The Trouble Shooting Guide helps you if you have a problem with your machine The Service Maintenance section is to help you with the...

Page 5: ...rotected environment Connection cable to convertor 10m length standard equipment with CE type plug and insulation Protective hose 5m length of rubber hose Pre Start Checks GB Before starting the job check the correct working of all the handling and safety devices If defects are found in the safety devices or other defects which could reduce the safe handling of the equipment stop working and notif...

Page 6: ...ion A moment of inattention while operating power tools may result in serious personal injury DRESS PROPERLY AVOID accidental starting BE SURE switch is off before plugging in Carrying tools with your finger on the switch or plugging in tools that have the switch on invites accidents REMOVE adjusting keys or spanners before turning the tool on A spanner or a key that is left attached to a rotating ...

Page 7: ...Operators Manual are observed Grounding and Potential Equalisation The correct and proper grounding assures the protection of people from dangerous voltage points entry exit and intermediate circuit voltage and through the leakage of parasitic currents and the low impendence potential equalisation it is an important instrument for the reduction of electromagnetic influences Filtering Filters are fit...

Page 8: ...cification and condition of cable according to standards of security 2 To disconnect switch off the Poker with the switch 3 Finally remove the Poker plug from the electrical supply Connection possibilities Make sure the total current A does not exceed the out put current specified in the electrical characteristic of the Poker EXTENSION CABLES Use three phase cables with the appropriate plugs If in d...

Page 9: ... been cut off A B a The minimum dimensions are printed in bold b The dimensions in brackets are the original dimensions c Replace the housing when it reaches the minimum diameter d Replace the tip when it reaches the minimum length DIMENSIONS OF WEAR FOR DIAMETERS AND LENGTHS OF THE POKER Model Diameter mm Length mm 35 33 5 35 278 283 51 49 5 51 291 296 57 55 5 57 337 342 Observe the waiting perio...

Page 10: ...le Group or their recognised agents for repair or assessment against a warranty claim on any machine 4 Materials and or labour costs to renew repair or replace components due to fair wear and tear The Belle Group and or their recognised agents directors employees or insurers will nor be held liable for consequential or other dam ages losses or expenses in connection with or by reason of or the ina...

Page 11: ... Om denne bruksanvisningen 11 Advarsel 11 Beskrivelse av maskinen 12 Tekniske data 12 Lagring 12 Transport 12 Kontroller før start 12 Generell sikkerhet 13 14 Helse og sikkerhet 14 Bruk 15 Feilsøkingsveiledning 15 Service og vedlikehold 16 Kretsdiagram 17 Garanti 17 Samsvarserklæring 2 Belle Group forbeholder seg retten til å endre maskinens spesifikasjoner uten foregående varsel eller andre forpli...

Page 12: ...iljø Kabel for kobling til omformeren 10m langt standardutstyr med plugg og isolasjon av CE typen Beskyttelsesslange 5 m lang gummislange Kontroll før start NO Før du starter jobben må du sjekke at alle håndteringsenhetene og sikkerhetsanordningene fungerer riktig Hvis du finner feil på sikkerhetsanordningene eller andre feil som kan redusere sikker håndtering av utstyret må du avslutte ar beidet o...

Page 13: ...l e l Et øyeblikks uoppmerksomhet kan føre til alvorlig personskade VÆR RIKTIG KLEDD UNNGÅ ufrivillig oppstart KONTROLLER at bryteren er slått av når du kobler til apparatet Du risikerer ulykker ved å bære verktøyet med fingeren på bryteren eller ved å koble til verktøy der bryteren er på FJERN justeringsnøkler eller spennstykker før du slår på verktøyet Et spennstykke eller en nøkkel som sitter ig...

Page 14: ...nbefalt i operatørhåndboken Jording og potensialutligning Riktig jording sørger for å beskytte personer mot farlige spenningspunkt inngang utgang og mellomliggende kretsspenning og er et viktig middel for reduksjon av elektromagnetiske påvirkninger gjennom lekkasjen av parasittstrøm og potensialutligning med lavimped ans Filtrering Filtrene settes inn i overføringsbanen mellom interferenskilden og...

Page 15: ... Til slutt tar du rørestangpluggen ut av strømforsyningen Koblingsmuligheter Forviss deg om at totalstrømmen A ikke overstiger utgangsstrømmen spesifisert i rørestangens elektriske karakteristikker SKJØTELEDNINGER Bruk trefasede kabler med de egnede pluggene Ta kontakt med en kvalifisert elektriker i tvilstilfeller ANBEFALINGER FOR BRUK AV BETONGOMFORMER 1 Velg riktig størrelse på rørestangen i forh...

Page 16: ...oblet ut A B a De minimale dimensjonene er angitt med fet skrift b Dimensjonene i parentes er de opprinnelige dimensjonene c Skift ut huset når det når minimal diameter d Skift ut spissen når den når minimal lengde SLITASJEDIMENSJONER FOR RØRESTANGENS DIAMETER OG LENGDER Modell Diameter mm Lengde mm 35 33 5 35 278 283 51 49 5 51 291 296 57 55 5 57 337 342 Rørestangen må være koblet ut ved fastkobl...

Page 17: ...er firmaer dette har godkjent for reparasjon eller evaluering mot et garantikrav på en maskin 4 Material og eller arbeidskostnader for fornyelse reparasjon eller utskiftning av komponenter grunnet vanlig slitasje Konsernet Belle Group eller firmaer ledere ansatte eller forsikringsselskaper dette har godkjent vil ikke bli holdt ansvarlig for følgeskader eller andre skader tap eller utgifter knyttet t...

Page 18: ...18 Vibratronic High Frequency Converter ...

Page 19: ...Box Bottom 230v 1 23 972 99921 972 99921 972 99921 Cover 1 24 972 99922 972 99922 972 99922 Gasket Rubber 1 25 972 99923 972 99923 972 99923 Switch Cover 1 26 972 99924 972 99924 972 99924 Switch Holder 1 27 972 99925 972 99925 972 99925 Cable Clamp 1 28 972 99926 972 99926 972 99926 Screws Switch 2 29 972 99927 972 99927 972 99927 Screws Switch Holder 2 30 972 99928 972 99928 972 99928 Screws Cov...

Page 20: ...m cn Belle Group Inc 3959 Electric Rd Roanoake Suite 360 VA 24018 USA Tel 1 540 345 5090 Fax 1 540 345 5091 Toll free 866 540 5090 e mail sales bellegroup net Belle Group World Parts Centre Unit 5 Bode Business Park Ball Haye Green Leek Staffordshire ST13 8BW Tel 44 1538 380000 Fax 44 1538 380038 Belle Poland sp z o o 96 200 Rawa Mazowiecka Ul Mszczonowska 36 Polska Tel 48 0 46 8144091 Fax 48 0 46...

Reviews:

Related manuals for VIBRATRONIC