6
Technical Data
GB
Model
BHB12 BHB19 BHB23
BHB19
USA
BHB25X
Restrictor
Open Open Open Open Open
Weight
(Kg)
14 19 23.5 19 27.5
Hydraulic
Flowrate
(Ltrs/Min)
20 20 20 20 20
Working Pressure (Bar)
70 - 90
90 - 110
90 - 110
90 - 110
90 - 110
Max
Pressure
(Bar)
160 160 160 160 160
Max. Return Line Pressure (Bar)
10
10
10
10
10
EHTMA
Category
C C C C C
Hydraulic Connections
1
/
2
BSP
1
/
2
BSP
1
/
2
BSP
1
/
2
JIC
1
/
2
BSP
Hydraulic Oil Type
- Below 30ºc
ISO VG T32
- Above 30ºc
ISO VG T46
Blow
Frequency
(Blows/Min)
2400 1600 1600 1600 1600
Accumulator
Gas
Pressure
(Bar)
40 40 40 40 40
Steel Size (mm)
22 x 82
25 x 108
25 x 108
32 x 152
32 x 160
Recommended Power Pack
Cub 20/90
Cub 20/90
Cub 20/90
Midi 20/140
Midi 20/140
Midi 20/140
Midi 20/140
Midi 20/140
Major 20/140 Major 20/140
Prelimenary Vibration - Cub (m/s
2
)
14.13 9.78 9.78 9.78 6.00
Prelimenary Vibration - Midi (m/s
2
)
16.08 11.97 11.97 11.97 6.00
Noise Level - Cub (dB(A))
101.74
102.67
102.67
102.67
107.00
Noise Level - Midi (dB(A))
104.30
104.03
104.03
104.03
107.00
Flat Faced, Quick Release, Non-Drip Couplings
Model
BHB25
BHB27 *
BHB30 USA *
Restrictor (mm)
3.8
3.4 Open 3.8 Open
Weight
(Kg)
28 28 28 31.5
31.5
Hydraulic Flowrate (Ltrs/Min)
20
20 30 20 30
Working Pressure (Bar)
105 - 125
105 - 125
105 - 125
105 - 125
105 - 125
Max
Pressure
(Bar)
160 160 160 160 160
Max. Return Line Pressure (Bar)
20
20
20
20
20
EHTMA Category
C
C D C D
Hydraulic Connections
1
/
2
BSP
1
/
2
BSP
1
/
2
BSP
1
/
2
JIC
1
/
2
JIC
Hydraulic Oil Type
- Below 30ºc
ISO VG T32
- Above 30ºc
ISO VG T46
Blow Frequency (Blows/Min)
1300
1300
2150
1150
1850
Accumulator
Gas
Pressure
(Bar)
50 50 50 50 50
Steel Size (mm)
32 x 160
32 x 160
32 x 160
32 x 152
32 x 152
Recommended Power Pack
Midi 20/140
Midi 20/140
Major 30/140
Midi 20/140
Major 30/140
Major 20/140 Major 20/140
Major 20/140
Prelimenary Vibration (m/s
2
) 11.1
11.8
18.61
10.75
16.06
Noise
Level
(dB(A))
106.36 105.86 105.34 107.16 105.73
Flat Faced, Quick Release, Non-Drip Couplings
*
NOTE:-
Breakers are supplied with alternative return pipe restrictors. Please ensure correct restrictor is fi tted for 20 or 30 Litre supply.
(Restrictor size is marked on the restrictor body)
NO MARKINGS = OPEN RESTRICTOR
More information can be found on the next page.