KIT INSTALLATION.
Follow the steps below, in the described order.
STEP 1.
Read the diagrams in this brochure and the technical manuals of the KIT (
VPA
,
VTx
,
SCU
).
STEP 2
. Make the electrical connections to the terminals (
ATM
,
VTM
,
VTA
) and then to the
VPA
outdoor panel.
STEP 3
.
Make the electrical connections of the
LCK
door lock and
LOCK SUPPLY
to the terminals of the
SCU
central unit
and, if necessary, the connections to: the
EXIT
button;
AUX
additional installations;
BAT
;
Vcam
analog video camera.
STEP 4. AUTHORIZED PERSONNEL!!! READ THE SAFETY INSTRUCTIONS FROM THE MANUAL OF THE SCU CENTRAL
SUPPLY UNIT!!! DISCONNECT
the fuses and make the
L
,
N
, connections to the
SCU
CONNECT
the fuses to the
power network. The ,
S2
LEDs turn on, and
S1
turns on only if the battery (12V/max. 42Ah) is connected.
STEP 5.1.
PROGRAMMING THE MAIN ENTRANCE PANEL
:
RFID CARDS/TAGs
At the
SCU
, long press (3 sec.) the
PROG
button (point 6). The
PROG
Red LED turns on Go to the
VPA
panel from the main entrance and touch each RFID CARD
to the (RFID) area for one second. For each programmed RFID CARD/TAG, the panel issues two beeps.
Follow the same steps for programming all the RFID CARDS/TAGs, for all the residents of the building.
Return to the
SCU
and short press the
PROG
button. The Red LED turns off. The main panel keeps
address 1
, which
is set from the factory and is ready to function.
STEP 5.2. PROGRAMMING THE ADDITIONAL PANEL: NEW ADDRESS and RFID CARDS/TAGs.
If the access in the building
is made through two entrances, the
VPA2
additional panel (point 11) from entrance 2 must be set up with
address 2
.
At
SCU 2
long press the
PROG
button. The
PROG
Red LED turns on. At the
VPA2
panel, long touch the
Fam.1
key
(long confirmation beep)
, then short touch the
Fam.1
key, twice. The panel confirms the storage of
address 2
with
two short beeps. Continue programming the CARDS/TAGs in the
VPA2
panel. Each touch of the CARD/TAG to the area is
confirmed by the
VPA2
with two beeps. Return to the
SCU2
and short press the
PROG
button. The Red LED turns off.
The
VPA2
and
VPA1
panels are ready to function, with all the terminals in the building.
STEP 6.1 PROGRAMMING THE ADDRESS OF THE Fam.1 TERMINAL.
The terminals keep
Address 1
, which is set by the
manufacturer.
STEP 6.2 PROGRAMMING THE ADDRESS OF THE Fam.2, Fam.3 or more TERMINALS.
The terminals for
Family 2
will have
address 2
, the terminals for
Family 3
will have
address 3
and so on for
4
,
5
etc.
Program the new addresses as follows
: At
SCU 1
long press (3 sec.) the
PROG
button. The
PROG
Red LED turns on
At the terminals for
Family 2
, long touch the key. The terminal confirms with one long beep. Short touch the
key twice. Two short beeps are issued. The terminal stores
address 2
. Continue programming
address 3
at
Family 3
following
the same steps. Long touch the key and after the long beep, short touch the key three times. Storage is confirmed
with three short beeps.
Return to the
SCU
and short press the
PROG
button. The Red LED turns off.
The terminals are
ready to function.
RECOMMENDED CABLES
(point 1) Maintain the same wire colors for the same connections.
2
Out of electrical safety reasons, we recommend installing a grounding cable (minimum 1.00 mm – Green/Yellow) from the
panel (VPM) to the central unit (SCU).
1
DETAILED PRODUCT CODES
VPA - advanced video outdoor panel
; Product codes:
1Fam
.VPA.1S(F)R02.xxy04;
2Fam
.VPA.2S(F)R02.xxy04;
3Fam
.VPA.3S(F)R02.xxy04;
5Fam
.VPA.5S(F)R02.xxy04 (S= Surface mounting, F= Flush mounting, R= RFID CARD/TAG access)
RFID access CARD/TAG
(secured at reading and copying). They are stored and can be deleted from the VPM.
ATM - smart+ audio terminal
; Product code: ATM.0S402.xxy04
VTM
- smart+ 3.5” video terminal
; Product code: VTM.3S402.xxy04
VTM/VTA
- smart+/advanced 7” video terminal
; Product codes: VTM.7S402.xxy04/ VTA.7S902.xxy04
VCB – Video connection box
(1 video input/4 video outputs - 4 Fam.); Product code: VCB.4DN02.xxy04
EN
INSTALLATION INSTRUCTIONS – VIDEO DOOR PHONE KIT
Thank you for choosing the
BELLCOME
products. We will assist you throughout the entire warranty period.
For technical support and assistance you can contact us at ELECTRA Building Communications GmbH +43 1 810 20 99,
2
1) Max. 75 ml 4 x 0.5 mm
(H03VV-F4G 0.5)
2
2) Max. 150 ml 4 x 0.75 mm
(H05VV-F4G 0.75)
3) Max. 250 ml UTP cat5e (AWG24)
or
UTP cat6e (AWG23)