BF Apartment Station 1 Way System 

PD-167 Issue 1B 

Installation and Operating Manual 

Page 8 of 44 

Multiple Entrances 

The bell

free

 system allows multiple entrances to be catered for by the addition of a door 

controller and entrance panel for each entrance and additional power supplies. 
In a multiple entrance system an optional feature allows the resident to view the cameras 
at all the entrances with successive touches of the 

view

 symbol. 

For  details  of  this  camera  feature  and  user  activation  see  the  setting  for  ‘Camera 
Numbering’ on page 20. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for 2-72 Multi Way

Page 1: ...ntry System With Hands free Colour Apartment Stations Installation Operation Manual This manual applies to the following BFD1 Way Door controller Version 1 Builds 1 BF Colour Apartment Station Version 1 Build 1 BS Colour Videophone Version 2 Builds 1 to 3 BSA Audio Phone Version 1 Build 1 ...

Page 2: ...BF Apartment Station 1 Way System PD 167 Issue 1B Installation and Operating Manual Page 2 of 44 bellfree Apartment Station BFD1 controller BSA audiophone BS videophone BS Deskphone ...

Page 3: ... 22 BF APARTMENT STATION SWITCH SETTINGS 23 BS VIDEOPHONE SWITCH SETTINGS 24 TROUBLESHOOTING 25 COMMON FAULTS 25 QUICK FAULT REFERENCE 25 SPECIFICATIONS 28 DIAGRAM A 1 WAY BASIC SYSTEM WIRING OVERVIEW 30 DIAGRAM B 1 WAY PCB DETAIL 31 DIAGRAM C 1 WAY BASIC SYSTEM WIRING DETAIL 32 DIAGRAM D 1 WAY MULTIPLE ENTRANCE WIRING OVERVIEW 33 DIAGRAM E 1 WAY MULTIPLE ENTRANCE WIRING DETAIL 34 DIAGRAM F EXTENS...

Page 4: ...nce such as houses individual flats and offices For multi way systems please refer to either the bellfree 2 72 way Video Entry System or bellfree Digital Video Entry System manuals The bellfree 1 way system is supplied with a dedicated door controller which has been specifically optimised for 1 way systems ensuring simple installation This basic system can support up to 3 extension apartment stati...

Page 5: ...4 System bellfree Colour Apartment Station View Pickup Display Contrast Mute Lock Ringer Volume Symbol Lamp Steady Flashing Mute on off Red Apartment station is muted Pickup end Blue Call in progress Ringing View camera select Lock Green Door is open Touch to release lock All symbols All Doorbell ...

Page 6: ... Controls The diagram in the introduction shows the apartment station and its controls The controls are adjusted by touching the end of the slider and sliding the finger up and down The default setting is ringer volume halfway and contrast slider fully down Auto Display When Auto Display mode is selected the picture will come on while the apartment station is ringing otherwise the picture will onl...

Page 7: ...ensions is limited only by power supply considerations All apartment stations will ring when called however typically only the master unit will display a picture while ringing Once the master or extension apartment station is picked up the picture will display on that unit alone An extra power supply may be used to allow extension apartment stations to display a picture while ringing Lock Type The...

Page 8: ...atered for by the addition of a door controller and entrance panel for each entrance and additional power supplies In a multiple entrance system an optional feature allows the resident to view the cameras at all the entrances with successive touches of the view symbol For details of this camera feature and user activation see the setting for Camera Numbering on page 20 ...

Page 9: ...entrance panel to ensure the best possible lighting conditions for the camera In general strong back lighting of the subject by the sun and sky should be avoided as the contrast between foreground and background may be too great for the camera The field of view should contain as little of the sky as possible particularly if south facing If a backlit situation is unavoidable additional lighting may...

Page 10: ...power supplies included within a standard kit or quotation assumes that all controllers are installed in one location and that there are no extensions The following table gives examples of the controllers and power supplies for a given number of entrance doors and extensions System Controllers and Power Supplies 1 door and 1 apartment station standard kit 1 x BFD1 door controller 1 x PS4 12V 4A po...

Page 11: ... is our short reference for EIA standard UTP Category 5 Unshielded Twisted Pair data cable This is a standard solid core twisted pair cable having 4 pairs 8 cores and no shield The cores are in pairs where Blue and Blue with a White stripe are twisted together as the first pair The other three pairs are similar with main colours Orange Green and Brown Also available and acceptable are UTP Category...

Page 12: ...1 x Cat5 2 x 1mm2 All apartment stations locally powered with a 340C power supply 300m 1 x Cat5 Locally powered apartment stations have Auto display extensions are daisy chained 25m to 340C 1 x pair of Cat5 100m to 340C 2 x 1mm2 Entrance to Door Controller Connection Distance Cable Comments Entrance Panel 50m 7 x pair of Cat5 See page 30 for details Lock Release up to 1A 10m 1 x pair of Cat5 50m 2...

Page 13: ...or the signal wiring and 1mm or greater cores for the power wiring refer to Page 11 for further details It is strongly recommended that a consistent colour code be used throughout such as that indicated on the connection diagram Certain signals must be interconnected using a twisted pair from the Cat5 cable These are clearly marked on the connection diagram and should be strictly observed Entrance...

Page 14: ...tment station unit is removed from the wall mounting box by pushing in the two circular buttons at the bottom and pulling apart once open far enough the two hanging clips will release lift off Replace the apartment station unit by hanging it on to the two hooks at the top of the wall mounting box and then push the bottom of the unit onto the two sprung clips Top bottom and rear cable entry alterna...

Page 15: ...t supplied Videophone Alternative to Apartment Station The BS Videophone is designed to be wall mounted onto plasterboard or other masonry at an optimum height of 1 6m DDA requirements may require this to be lower Remove the top cover of the Videophone which is secured by clips at both sides by using both hands and placing fingers under the edges and using thumb pressure to release the clips If to...

Page 16: ...ton Fire officers usually require a minimum of door handle or push bar to open a door on a fire exit route not a thumb turn Most fail secure locks are not continuously rated and if an electrical hold open system is used for say busy times then a continuously rated release must be used Powered bolt shoot bolt or other more secure door locking systems may require the use of separate power supplies o...

Page 17: ...r the first time it is highly recommended that only the most basic system be connected i e 1 BF apartment station 1 door controller and panel and 1 video controller the remaining equipment can be isolated by unplugging terminal blocks Proceed to test the system by calling the apartment station from the door panel in the usual way Any problems can be resolved by rechecking wiring and connections as...

Page 18: ...ng every 3 seconds On On Off On 10s 1 in 3 1 ring every 3 seconds On On Off Off 15s 1 in 3 1 ring every 3 seconds On Off On On 20s 1 in 3 1 ring every 3 seconds On Off On Off 30s 1 in 3 1 ring every 3 seconds On Off Off On 40s 1 in 3 1 ring every 3 seconds On Off Off Off 45s 1 in 3 1 ring every 3 seconds Off On On On 50s 1 in 3 1 ring every 3 seconds Off On On Off 60s 1 in 3 1 ring every 3 seconds...

Page 19: ...default allows for no switch fitted On Contacts Closed when Door is Closed Standard normally closed switch SW2 6 Camera 2 How many cameras at this door Off Camera 1 only Default single camera per door On Enable Camera 2 Second camera at the door SW2 7 View Function Camera action when view symbol touched Off Local View View symbol only selects the camera s at this door On Global View See DIP SW3 be...

Page 20: ...TV mode The CCTV Mode SW2 8 setting must only be enabled at one door Camera 1 at this entrance will then be the first camera to be viewed Global View at Multiple Entrances If Global View is enabled successive touches of the view symbol will enable all entrance to be viewed in turn including any second cameras if enabled Setting up the door controllers to enable Global View requires careful setting...

Page 21: ...ing coaxial cable 100R for terminating twisted pair Cat5 cable and None for use when passing the cable on to another device or controller Video Gain Control The Video Gain jumper on door controllers should always be set to 0 unless directed by Bell System Technical Support This jumper is only required on some systems with very long cable runs camera to apartment station well in excess of 150m Inap...

Page 22: ...me level and 8 presses of Vol halves it Pressing Save stores the new value Increasing the volume too far will make speech less stable and there will be a tendency for feedback intermittent screeching and howling If this happens press Vol four times and Save and test again The new level is tested by ringing one or more apartment stations and talking to them Finally return the jumper to its original...

Page 23: ...ff Off 10 hours Off Off Off Off Indefinite Default setting Disabled means touching the mute symbol has no effect Indefinite the mute is cancelled by touching the symbol again Individual Functions DIP SW 5 8 SW 5 Master Extension Which Apartment Station to set Off Master Only or first apartment station per BSC4 output On Extension Slave Second and subsequent apartment stations per BSC4 output SW 6 ...

Page 24: ... button again Individual Functions DIP SW 5 8 SW 5 Master Extension Which videophone to set Off Master Only or first videophone per BSC4 output On Extension Slave Second and subsequent videophones per BSC4 output SW 6 Auto Display on Ring Videophone display behaviour Off Display during ring Picture is on while ringing stays on when answered On No display during ring Picture is off while ringing co...

Page 25: ...f the possible fault Power Problems Apartment station resetting The three indicators lights show the power on sequence Power supply intermittent short or overload More than 1 extension enabled for auto display Lock output short circuit see Lock Problems 28V LED does not light on controller Temporarily remove connection to 28V output If it now comes on there is a short on the apartment station wiri...

Page 26: ...nk picture when Calling apartment station or touching view Broken or missing Video or Video connection Cameras incorrectly configured refer to SW2 6 settings on page 19 Call is from an audio only panel No picture when calling apartment station Check Auto display switch is on See page 23 No picture when touching view for CCTV mode Another apartment station in use No entrance has SW2 8 set to Enable...

Page 27: ...o 2 connection Intermittent or broken Data A or Data B connection Apartment station has reset see the power faults table More than one entrance has SW2 8 set to Enable causing 2 entrances to become active on CCTV request No speech from apartment station to entrance Missing or Broken Spkr or Spkr connection No speech from entrance to apartment station Missing or Broken PM or PM connection ...

Page 28: ...92º typical Video Output PAL composite video 1Vpk pk 75 Ohm Resolution More than 330 lines Back light compensation Yes BF Colour Apartment Station Size 144mm x 202mm x 50mm 20mm When flush Fixing Wall Mounted Supply Voltage 11V minimum local power supply only 20V to 28V typical Current Consumption 25mA 28V idle 375mA 11V active Buzzer Mute Time Disabled 1minute through 10 hours indefinite BS Colou...

Page 29: ...ble Supply Voltage 230V 50Hz nominal Temperature Range 0 ºC to 50 ºC 340C Power Supply Size 140mm x 60mm x 53mm Output Voltage regulated 13 5V Min 13 8V Nom 14 1V Max Output Current 1A continuous 1 5A peak 5 minutes max Mains Supply Internal Fuse Not user replaceable Supply Voltage 230V 50Hz nominal Temperature Range 0 ºC to 50 ºC 840 Power Supply Battery Backed Size 350mm x 330mm x 80mm Output Vo...

Page 30: ...ntroller Up to 50m 2x Cat5 Cat5 Options Lock wiring options Lock 0 5A 1 0A 12m 1 pair 1 pair 25m 1 pair 2 pair 50m 2 pair 4 pair 50m 2x1mm 2x1mm All cable MUST be 4 pair data cable Except for power wiring where stated Cat5 Up to 150m 1 Apartment station For over 150m or extensions see diagrams F G Cat5 3m Max 230V Mains Entrance Options Exit button 1 pair Door monitor 1 pair Trades 1pair BF Apartm...

Page 31: ... 28V 12V 12V Audio Audio Door Data Data Lock Commn LR B1 B2 bell BFD1 issimo Enhanced Speech Door Controller Door Panel DDA Entrance Power Input Output Status 1 1 Prog 6 HF Prog Vol Speech Vol Panel Speaker Save Lock Power Test SW1 Off On Off On Off On SW2 SW3 Cam2 Audio Phone Power 28V Video 100 75 High 100 75 High Cam1 Cam2 4 3 2 1 0 Video Gain Label BFD1 Version No Build No Panel Tone Volume 28...

Page 32: ...rn W Brn W Brn Org W Org Grn W Grn Grn pair Blu Blu Black Red W Blu W Blu Lock Exit button or Fire Switch optional Door Monitor Switch optional 2 x 1mm CO NO NC TS2000 Time Clock Optional 230V Mains PS4 Power Supply 12V CAMBS Camera Optional Link For Infra Red Lamp S 1 M 12V Spkr PM Mic BF AMP Speech Unit Panel Mic Brn W Brn Org W Org Grn W Grn Blu W Blu 2 1 B A Video Bell 28V Audio Data BF Apartm...

Page 33: ...at5 Options Options Lock wiring options Lock 0 5A 1 0A 12m 1 pair 1 pair 25m 1 pair 2 pair 50m 2 pair 4 pair 50m 2x1mm 2x1mm All cable MUST be 4 pair data cable Except for power wiring where stated Cat5 150m Max 1 Apartment station For over 150m or extensions see diagrams F G Cat5 Cat5 Cat5 Entrance Options Exit button 1 pair Door monitor 1 pair Trades 1pair Further Entrances Entrance 2 Entrance 1...

Page 34: ...o Data Data Data Data Commn Commn BFD1 Door Controller 1 Way BFD1 Door Controller 1 Way Power Supply Power Supply 2 x 1mm Cat5 Input Cat5 Input Cat5 Output Cat5 Output Monitor Power Monitor Power IMPORTANT Both wires 1 terminal Brn Brn W Brn W Brn Org Org W Org W Org Grn Grn W Grn W Grn Blu Blu W Blu W Blu Cat5 Cat5 From Previous Door Controller Output if present Cat5 28V generator 28V generator B...

Page 35: ...its see next Diagram Extension video units must be daisy chain wired to preserve video quality The last or only video unit on the cable requires the Video Terminator ON all other video units must have the Video Terminator OFF 2 1 B A 28V Audio Data BSA Audio Phone Cat5 From Controller To More Extensions Brn W Brn Org W Org Grn W Grn Blu W Blu Org W Org Grn W Grn Blu W Blu Brn W Brn Org W Org Grn W...

Page 36: ...ality The last or only video unit on the cable requires the Video Terminator ON all other video units must have the Video Terminator OFF Video Bell Bell 28V Audio Data Video 28V 12V Audio Data BF Apartment Station Cat5 From Controller To More Extensions PSU 340C 12V The 28V connection must be made between all units and the controller For maximum cable distance see text Brn W Brn Org W Org Grn W Gr...

Page 37: ...H Camera Sharing Time Clock Sharing Camera Termination Options Cameras may be wired in either twisted pair or coax and shared with other equipment Time Clock Sharing A time clock can be shared between distributed equipment areas by borrowing one of the comm wires in the interconnecting Cat5 to use as the shared Time clock common The Time clock common signal is sharable across all Bell controller t...

Page 38: ... 1 Camera 2 Panel Misc BFD1 Door Controller 1 Way Door Panel Extended Panel Speech wiring as per main diagram DDA panels are partly prewired LL LL B1 B1 LC LC B2 B2 LS LS DDA LED PCB 1 1 B1 B2 Call Button Wiring Detail _ C NO NC NC NO C C _ 1 CAMBS Camera Optional Link For Infra Red Lamp S 1 M CAMBS Camera Optional Link For Infra Red Lamp S 1 M ...

Page 39: ...to the proximity wiring Alternatively the exit button can be wired to the proximity reader ACT 1000 2000 3000 Proximity Controller or 100e 200e Extender The lock output on an ACT controller is a volt free relay contact so as long as it is not used for another purpose it can be directly connected to the exit input of a bellfree door controller A 2 wire interface is shown but if a common 12V supply ...

Page 40: ... be wired to the Bellcode unit in addition to the bellfree wiring Note 2 A 12V connection will be required if the 2 units are not sharing a power supply Taking an Output From a Third Party System For 12V a c systems use an 88 relay and for 12 d c systems use an 89 relay For systems with other lock voltages a relay with a suitably rated coil will be required For systems with a fail safe output the ...

Page 41: ...lock release or Maglock using the ACT Manuals 2 Leave the bellfree controller set to Fail Secure regardless of the type of release used 3 A normally open exit button can still be fitted to the ACT controller in addition to the bellfree wiring 4 If the 2 units are not sharing a power supply then a connection from bellfree controller Exit to ACT 0V will be required 5 Look for the notes on the ACT in...

Page 42: ...to Exit wire is only needed if the two units do not share a common power supply Opening a Gate or Locks on Third Party Systems The bellfree door controller is set to fail secure Use COM and NO or COM and NC as required for the gate controller or third party access system bellfree Door Controller bellfree Door Controller Exit Bellcode 200 Controller Lock Exit Lock Coil Coil Com NO NC 89 Relay Volt ...

Page 43: ...uld only be connected once the system has been fully tested Connection is made by 2 leads with spade terminals observe the correct polarity red to positive black to negative Care must be taken to ensure that the terminals of the battery are not shorted together by metal objects as this may constitute a Fire Hazard The Control Cabinet is IP55 rated to exclude dust and is vented to avoid the build u...

Page 44: ...rate numbers Tel 0845 121 4008 Sales and Technical Support FAX 0845 121 4009 E mail sales bellsystem co uk technical bellsystem co uk Website www bellsystem co uk Standards This product complies with European directive 89 336 EEC on Electromagnetic Compatibility and Low Voltage Directive 72 23 EEC Emissions Generic BSEN 61000 6 3 Immunity Generic BSEN 61000 6 1 Low Voltage Generic BSEN 60950 BS EN...

Reviews: