Camera Numbering DIP SW3 (1-8)
Camera 1 at this door
Last Camera
4 3 2 1 Number
8 7 6 5 Number
On On On On *1
On On On On *1
On On On Off 2
On On On Off 2
On On Off On 3
agama
On On Off On 3
On On Off Off 4
On On Off Off 4
On Off On On 5
On Off On On 5
On Off On Off 6
On Off On Off 6
On Off Off On 7
On Off Off On 7
On Off Off Off 8
On Off Off Off 8
Off On On On 9
Off On On On 9
Off On On Off 10
Off On On Off 10
Off On Off On 11
Off On Off On 11
Off On Off Off 12
Off On Off Off 12
Off Off On On 13
Off Off On On 13
Off Off On Off 14
Off Off On Off 14
Off Off Off On 15
Off Off Off On 15
Off Off Off Off 16
Off Off Off Off 16
*Default setting
View Activated by User (CCTV mode)
The ‘CCTV Mode’ (SW2-8) setting must only be enabled at one door. Camera 1 at this
entrance will then be the first camera to be viewed.
‘Global View’ at Multiple Entrances
If ‘Global View’ is enabled, successive touches of the view symbol will enable all entrance
to be viewed in turn, including any second cameras, if enabled.
Setting up the door controllers to enable ‘Global View’ requires careful setting of the
switches. Not all entrances have to participate in ‘Global View’, and these entrances
should remain set to ‘Local View’.
For the participating entrances number the cameras 1, 2, 3, …etc. It is recommended that
the entrance selected for CCTV is also numbered as camera 1
NB. The sequence must start with 1; the maximum is 16. If an entrance has 2 cameras
then it will have 2 consecutive addresses.
Each controller must also record the last camera number in the sequence – this will be the
same setting for all participating entrances.
SW1 SW2 SW3
(ASDFGH
JK)
(ASDFGH
JK)
(123456
78)
OFF ↔ ON