background image

SECTION 

502-541-407 

66£3  OR  66£4 

CONN  BLOCK 

(NOTE  3) 

D30C  (564HK)  OR 

D30D  (564HL) 

63�A 

MTG  CORD 

KEY 

(I) 

PU 

26 

Ft 

lA I·IA2 

KTS 

LINE 

CONNS 

RINGER 

IAI·IA2 

KTS  A 

LEAD 

CONNS 

IAI-IA2 

KTS 

LAMP 

CONNS 

BUS 

LAM 

8UZZER 

LEADS 

R  (I) 

R  (2) 

R  (3) 

T  (4) 

R  (4) 

(5) 

R  (5) 

Bl 

AI 

(I) 

A  (2) 

S  OR  51 

A  (3)  S  OR  51 

S  OR  S I 

(5) 

S  OR  51 

LG 

LG  (I) 

L  (2) 

LG 

LG  (3) 

(4) 

LG  (4) 

Y  BL 

BZ 

BZI 

SPARE 

SPARE 

SIGMA 

GROUN 

SG 

(BL·W) 

(BL) 

29 

(W-BR) 

(BR-W) 

1

(R-0) 

1

20 

26 

10 
38 

LS 

40 

39 

15 

2

27 

41 

12 

1

18 

44 

24 

30 

37 

36 

3� 

34 

33 

38 

20 

45 

(O-W) 

IW-01 

(w-s) 

(R-G) 

IH 

2H 

3H 

39 

28 

31 

34 

37 

12 

40 

15 

LG 

LH 

44 

17 

(O·Y) 

�ez���I9LI 

42 

(Y-01 

19 

SG 

(S-R) 

TRMTR 

G3AR 

���SET 

HIB 

RINGER 

I NOTES 

1,2, AND 3) 

Kt 

NOTES: 

LEGEND: 

PU 

- PICKUP  KEY 

H-

HOLD  KEY 

DP 

-

IAL  PULSE  CONTACTS 

ON-

DIAL  OFF-NORMAL  CONTACTS 

LS-

LINE  SWITCH 

L2 

I,  CONNECTIONS  FOR  HIB  RINGER  SHOWN,  WIRE 

HIA  RINGER  AS  FOLLOWS: 

(BK)  TO  RT 

(S)  TO  K  OF  NETWORK 

(S-R)  TO  A  OF  NETWORK 

(R)  TO  RR 

2,  IF  CAPACITOR  IS  NOT  REQUIRED  IN  RINGER 

CIRCUIT,  MOVE  (S)  RINGER  LEAD  TO  A 

TERMINAL  FOR  HIA  RINGER  OR  (R)  RINGER 

LEAD  TO  A  TERMINAL  FOR  HIB  RINGER, 

3,  FOR  BRIDGED  RINGER  SERVICE  MOVE  (R)  AND 

(BK)  RINGER  LEADS  TO  RING  AND  TIP 

RESPECTIVELY  OF  LINE  INVOLVED.  TO  SILENCE 

RINGER  INSULATE  OR  STORE  (R)  AND  (BK) 

LEADS  ON  A  AND  K  TERMINAL 

OF 

NETWORK. 

4.  66E3  OR  66£4  CONNECTING  BLOCK  SHOWN. 

MOUNTING  CORD  MAY  BE  PLUGGED  INTO 

CONNECTOR  CABLE.  CONDUCTOR  COLORS  AND  PIN 

NUMBERS  FOR  CONNECTOR· CABLE  AND  MOUNTING 

CORD  ARE  I DENT! CAL. 

5. 

BL  LEAD  CONNECTED  TO  NETWORK  L2  PUNCHING 

ON  LATER  MODEL  TELEPHONE  SETS. 

6.  LINE  SWITCH  OFF-HOOK  SEQUENCE: 

d,e 

CLOSES 

b,c 

CLOSES 

f ,Q 

OPENS 

7.  STRAP  BETWEEN  TERMINALS  28,31,34,37,  AND 

40  PRDV I OED 

ON 

D300  CORD 

OIIL 

Y. 

8. 

IF  HOLD  POSITION  LAMP  IS  REQUIRED,  USE 

SPARE  PAIR  AND  SPARE  TERMINALS  OR 

D-161488  CONNECTORS. 

TERMINAL  ON  NETWORK. UNLESS  DESIGNATED 

TERMINAL  IS 

ON 

KEY  TERMINAL  BOARD. 

(  )  CURRENT  COLOR  CODE 

I  I 

MD 

COlOR 

• 

Fig. 

3-564HK 

{MD)  and 

564HL 

Telephone  Set,  Connedlons • 

Page 

Pages 

BSP 

502-541-407-i03_1973-06-04.jpg 

Scanned by Frank  Harrell, (Cowboy  Frank) Castle Rock, Colorado  Feb 

02,2012  19:10:14 

Summary of Contents for 564HK

Page 1: ...of set 2 To replace housing guide lower front of housing over pushbuttons align housing with base of set and gently press housing into place Tighten captive screws in base of set 2 04 Replace cracked pushbuttons or collars Remove accumulated dirt or film from lamps collars and pushbuttons with a water dampened cloth DO NOT USE SOL VENTS OF ANY KIND If cleaning does not correct binding of pushbutto...

Page 2: ...ephone sets are factory equipped with a KS 20419Ll 10 volt AC only buzzer Page 2 3 03 Current models of the 564HL telephone sets are furnished with the HlB ringer 3 04 Red and black ringer leads are factory wired to terminals RR and RT Refer to notes in Fig 3 for ringer connections when bridged ringing on a particular line is desired BSP 502 541 407 i03_1973 06 02 jpg Scanned by Frank Harrell Cowb...

Page 3: ...te or intercommunicating lines with the signal key common to each line The signal key under con trol of the line switch will operate the signal circuit of each line when associated pickup key is depressed Use S lead on 2nd 3rd or 4th pickup key as required Notes 1 All convertible key positions are arranged in the factory as pickup positions To con vert a key position from pickup locking to signali...

Page 4: ...E HIA RINGER AS FOLLOWS BK TO RT S TO K OF NETWORK S R TO A OF NETWORK R TO RR 2 IF CAPACITOR IS NOT REQUIRED IN RINGER CIRCUIT MOVE S RINGER LEAD TO A TERMINAL FOR HIA RINGER OR R RINGER LEAD TO A TERMINAL FOR HIB RINGER 3 FOR BRIDGED RINGER SERVICE MOVE R AND BK RINGER LEADS TO RING AND TIP RESPECTIVELY OF LINE INVOLVED TO SILENCE RINGER INSULATE OR STORE R AND BK LEADS ON A AND K TERMINAL OF NE...

Reviews: