background image

Pur

eA
V P

o

w

er C

ons

ole

Safety Precautions

Warning – Grounding and Polarization

This product must be plugged directly into a grounded AC power outlet 
(3-prong). Do not use a 3-to-2-prong adapter to defeat the grounding pin. Do
not plug or “daisy-chain” this product into other electrical products such as
surge protectors, power strips, or UPSes. Do not plug this product into an
extension cord. Failure to plug this product directly into a grounded outlet
may result in personal injury or damage to your equipment. Call a licensed
electrician if you are unsure if your AC outlets are properly grounded.

Warning – Rooftop Antennas and Satellite Dishes

If you use rooftop antennas, satellite dishes, or any other rooftop hardware
that connects to your PureAV Power Console, make sure that all the wires
leading from these components are properly grounded. This will protect
against voltage surges from lightning strikes or static charges.

Warning – Lightning Storm Protection

Although your PureAV Power Console is built to withstand large power
surges, we cannot guarantee that it will protect all of your equipment in the
event of a large lightning storm. In the event of a lightning storm, it is best
to unplug your Power Console from the wall. Once you have done this,
there is no need to unplug any of the equipment that is connected to the
Power Console.

Warning – Water and other Liquids: Shock Hazard

Do not use this product with aquariums or other water-related products.
Use indoors and in dry locations only. Do not operate the Power Console 
if any liquid is spilled on or in the unit. Failure to follow these guidelines
could result in serious bodily injury or death.

Warning – Cleaning

Always unplug the Power Console before cleaning. It is only necessary to
clean the Power Console with a clean, dry cloth or duster. Do not use any
cleaning solutions, sprays, or water.

Warning – No User-Serviceable Parts Inside

If for any reason your Power Console is malfunctioning, do not attempt 
to repair or dismantle the unit in any way. Unplug the unit and consult this
User Manual for warranty and service contact information.

Warning – Power Cord Safety

Do not route the Power Console’s AC power cord near heat sources. 
This could damage the power cord and cause it to malfunction, creating 
a shock hazard.

Do not route the Power Console’s AC power cord in heavy foot-traffic areas
where it could create a trip hazard (hallways, doorways, across room).

If the power cord is frayed, ripped, cut, or damaged in any way, please
discontinue use immediately and refer to the warranty section of this
Manual for instructions.

3

Summary of Contents for PF60 - PureAV Home Theater Power Console Surge Suppressor

Page 1: ...AP41300 12 Home Theater Power Protection with PureFilter Technology Power Console PF60 User Manual Clear Picture Clean Sound...

Page 2: ...nents to Digital Filter 1 and Digital Filter 2 Bank 01 and Bank 02 12 Step 6 Connect Video Components to the Video Filter Bank 03 13 Step 7 Connect Audio Components to Audio Filter 1 and Audio Filter...

Page 3: ...anced Overvoltage Protection which automatically disconnects power from your equipment when the input voltage reaches a dangerous level and restores power automatically when the voltage returns to a s...

Page 4: ...ug your Power Console from the wall Once you have done this there is no need to unplug any of the equipment that is connected to the Power Console Warning Water and other Liquids Shock Hazard Do not u...

Page 5: ...e AC Control Cable Remote DC Control Cable 1 8 mini plug cable RJ45 Ethernet Patch Cable For broadband connectivity RJ11 Phone Cable PureAV Coaxial Video Cable One sheet of PureAV cable labels One pai...

Page 6: ...nd interference to your video components 7 Audio Filter 1 ensures optimum reduction of line noise and interference to your audio components 8 Audio Filter 2 ensures optimum reduction of line noise and...

Page 7: ...wn your coaxial cable lines 15 Broadband Ethernet Input Output protects broadband Ethernet lines used for digital media receivers gaming or broadband Internet access from dangerous power surges 16 15...

Page 8: ...for flush installation in the rack D Attach the bracket to the side of the Power Console with the screws provided Fig 1 You must use a minimum of four screws to mount each bracket E Repeat steps 3 an...

Page 9: ...1 These outlets will remain powered on for a short period of time after switching them off depending on the Delay Time setting see Delay Time Switch below C Outlet Banks Switched On After Delay You ma...

Page 10: ...8 mini plug cable Set the Trigger Out switch to Delayed and the Trigger Out will power an external device after a delay set by the Delay Time Switch Fig 2e If you do not want a delay then set the Trig...

Page 11: ...AC Control Cable into the Remote AC IN outlet located on the back of the Power Console Fig 3a B Press the Remote button on the front of the Power Console to turn on the remote function The LCD displa...

Page 12: ...ntrol Cable included into the outlet labeled DC IN on the rear panel of the Power Console Fig 4a B Press the Remote button on the front of the Power Console to turn on the remote function The LCD disp...

Page 13: ...audio and high current audio components A Attach PureAV power cord labels to each component s power cord before you plug the cord into the corresponding outlet on the Power Console B Cable Satellite...

Page 14: ...ideo components from connected digital audio and high current audio components A Attach PureAV power cord labels to each component s power cord before you plug the cord into the corresponding outlet o...

Page 15: ...tach PureAV power cord labels to each component s power cord before you plug the cord into the corresponding outlet on the Power Console B CD Connect your CD player power cord to the outlet labeled CD...

Page 16: ...on last and turn off first avoiding that annoying and potentially damaging thump from getting to your speakers A Attach PureAV power cord labels to each component s power cord before you plug the cord...

Page 17: ...the other end of your telephone cable to the Power Console phone jack labeled IN B Connect one end of the PureAV phone cable included to the Power Console phone jack labeled OUT Connect the other end...

Page 18: ...xial cable to the connector labeled SAT OUT Connect the other end of this cable to your satellite TV tuner C Antenna Connect the incoming TV or radio antenna cable line to the connector labeled Antenn...

Page 19: ...tch cable to a network jack either directly to a router or wired network wall jack Connect the other end of the network patch cable to the network jack labeled IN B Connect one end of the broadband Et...

Page 20: ...Wiring indicates whether the AC outlet to which the Power Console is connected is wired properly or cross wired Wiring ok Hot and neutral wires are reversed See page 22 of the Troubleshooting section...

Page 21: ...ont auxiliary power outlet This outlet contains a digital noise filter and is a convenient place to connect digital video cameras digital still cameras MP3 players or any other portable device in need...

Page 22: ...to reset Power should be restored to the outlets on the Power Console Your components may be plugged into a Switched outlet and the outlet is not switched on Check to ensure that the Switched ON indi...

Page 23: ...onsole and consult an electrician to properly ground the outlet If the outlet is properly grounded and the Ground Fault indicator is still lit the Power Console may be malfunctioning Please call Belki...

Page 24: ...ro voltage potential Common connecting points are ground rods or cold water pipes that are connected to the Earth Joule Rating A measure of electrical energy The higher the joule rating the more elect...

Page 25: ...nt shall be the current value of the equipment specified in the most recent edition of the Orion Blue Book by Orion Research Corporation Roger Rohrs Publisher Belkin Corporation reserves the right to...

Page 26: ...mplied including the implied warranty or condition of quality merchantability or fitness for a particular purpose and such implied warranties if any are limited in duration to the term of this warrant...

Page 27: ...e e Where you purchased the PureAV Power Console f When you purchased the PureAV Power Console g Copy of original receipt h Your Belkin Customer Service Representative will then instruct you on how to...

Page 28: ...x 44 0 1933 31 2000 belkin com Belkin Components B V Starparc Building Boeing Avenue 333 1119 PH Schiphol Rijk The Netherlands Tel 31 0 20 654 7300 Fax 31 0 20 654 7349 Belkin Ltd 7 Bowen Crescent Wes...

Reviews: