background image

 I

ndicator  

Condition 

Meaning

ON LINE

 

 

Solid Green 

AC power is on.  

(Green LED)

 

* Flashing Green 

AVR is active.

ON BATTERY 

*

 Flashing Yellow 

 

(Yellow LED) 

LED with Audible  

 

Alarm (Beeping)

FAULT

 

Solid Red 

OVERLOAD 

Replace Battery

 

(Red LED)

 

* Flashing Red 

SITE 

Solid Red 

WIRING FAULT 

(On Rear Panel)

This condition for the “ON BATTERY” LED can 
indicate 1 of 2 problems:
1.  The Unit is in backup mode and an 

intermittent audible alarm is on.  
The Unit will begin shutdown procedure.

2.  Battery is low. The Unit will start shutdown 

procedure. The buzzer sounds an  
audible alarm.

The “FAULT/OVERLOAD” LED can indicate  

1 of 2 problems.

1.  There is a problem with the Unit. The LED  

will be lit continuously, and the Unit will  
sound an audible alarm for 10 seconds.

2.  Battery is weak or bad; the battery needs  

to be replaced. 

Battery output is drawing more power than the 
Unit can provide.

There is either no ground circuit or a reversed 
polarity in the building wiring.

                 

  

Model 

 

  F6C550        F6C750          F6B750       F6C900        F6C1100      F6C1200              

    

 

 

  

-AVR              -AVR                 -AVR           -UNV             -UNV             -UNV               

Input

 

Capacity 

 550VA/ 

       750VA/ 

               900VA/

     1100VA/    1200VA/ 

 

                                     330W                    400W                    540W          660W         670W

 

Voltage Range 

89–145VAC

 

Frequency 

60Hz (±5Hz)

Output

 

Voltage 

Simulated sine wave, 120VAC ±15%

 

Frequency 

60Hz (±1Hz) 

 

(On Battery) 

Battery

 

Backup Time 

   8 min.  

         5 min.                  6 min. 

  4 min. 

 

Half-Load 

 

Typical  

 

 

Recharge 

16 hours recover to 90% capacity   

 

Time 

Environment

 

Ambient  

0~90% humidity non-condensing, 0~40º C 

 

Operation 

  

Conformance

 

Safety  

UL / c-UL, FCC Class B    

 

Surge 

IEEE C62.41 Category A standard

Physical

 

Dimensions  

294.5 X 125 X 242.5 mm. 

 

(W x H x D)  

 

Net Weight 

  5.9kg.                      6.25kg.   

             9.25kg .

All specifications are subject to change without prior notice.

 

F6B900-UNV, F6C900-UNV, 

Battery Backup with Surge Protection        User Manual

  

F6C1100-UNV, F6C1200-UNV

 

F6C550-AVR, F6C750-AVR, F6B750-AVR, 

Battery Backup with Surge Protection        User Manual

  

F6C900-UNV, F6C1100-UNV, F6C1200-UNV

     Fig.1                Fig.2                         Fig.3

Introduction

Thank you for purchasing Battery Backup with Multi-Computer Connections 
(the Unit). Each year, frequent natural and man-made power disturbances 
disrupt the power supplied to your home or office electronics. These power 
problems place your hardware, software, and data at risk. Belkin Battery 
Backups provide an uninterruptible power supply (UPS) with advanced 
features as the industry-leading solution.

Package Contents

You should have received the following:

 

1 –  Battery Backup unit

 

1 –  Installation CD containing Belkin Automatic Power Management  
 

Software (the Belkin APM Software) for Windows

®

 

1 –   USB Cable

 

1 –   Serial Cable(F6C900-UNV, F6C1100-UNV, F6C1200-UNV)

 

1 –   Phone-Line Cable 

 

1 –   Coaxial-Cable(only F6B750-AVR)

System Requirements

The Unit can be used without the software and can be used with any computer 
using a monitor or a flat-panel screen. Also, you do not have to have the software 
installed to utilize the battery-backup outlets.

To fully utilize the Battery Backup and its software, your computer must be able to 
run one of the following operating systems: 

Windows XP / 2003 / 2000 / ME / 98 / 

NT 4.0 (SP6)

 or Linux, and it must have a serial or  

USB port.

Overview   |   Features and Functions

Your Battery Backup features three LED indicators that monitor certain 
functions on the Unit. Please review the front-panel diagram and refer to this 
chart. This will assist you in the use of your Battery Backup.

Overview   |  Alarms

Battery Backup (Slow Alarm) 

When the Unit is in “backup” mode (running on battery), the YELLOW LED 
illuminates and the Unit emits an audible alarm. The alarm stops when the 
Unit returns to normal online operation.

Low Battery (Rapid Alarm)

In “backup” mode, when the battery energy runs low, the Unit beeps rapidly 
until it either shuts down from a depleted battery or returns to normal  
online operation.

Overload (Continuous Alarm)

When the Unit is overloaded (the connected loads exceed the maximum 
rated capacity), it emits a continuous alarm to warn of an overload condition. 
Disconnect nonessential equipment from the Unit to eliminate the overload.

Fault (10 Seconds Continuously)

When the Unit fails, it emits an audible alarm continuously for 10 seconds to 
warn of a fault condition. Disconnect the equipment prior to checking it.

Installation

Note!

Before installation, please inspect the Unit. Make  
sure that nothing inside the package is damaged.

Connect to AC Utility Power

Plug in the AC cord to a wall outlet. Please make sure there are no 
devices plugged into the Unit. Check to see whether the “SITE WIRING 
FAULT” indicator is lit. If it is lit, have the utility wiring inspected by an 
electrician. 

Charging the Battery

For best results, charge the battery for eight hours prior to initial use. The 
Unit charges its battery whenever it is connected to the utility power. 

Plug in Power Devices

Plug your devices into the AC outlets on the top of the Unit. To use the Unit 
as a master on/off switch, make sure all of the loads are switched on.

Caution: Never connect a laser printer or scanner to the backup 
outlets along with other computer equipment. A laser printer or 
scanner draws significantly more power when in use than when 
idle. This may overload the Battery Backup.

Turning on the Unit

Turn on your Battery Backup by pressing and holding the “ON/OFF/TEST” 
button for approximately two seconds until the “ON LINE” green light comes on.

Turning off the Unit

Turn off the Unit by pressing and holding the “ON/OFF/TEST” button for 
more than two seconds until the “ON LINE” or “ON BATTERY” LED goes off.

To Conduct a Self-Test

Use the self-test to verify both the operation of the Unit and the condition 
of the battery. In normal utility power, push the “ON/OFF/TEST” button less 
than 1.5 seconds and the Unit performs a self-test function. During the  
self-test, the Unit operates in backup mode.

Note: During the self-test, the Unit briefly operates on battery-backup 
power (the “ON BATTERY” LED comes on). If the Unit passes the 
self-test, it returns to online operation. If the Unit fails the self-test, it 
immediately returns to online operation and lights the “Replace Battery” 
LED. The loads are not affected. Recharge the battery overnight and 
perform the self-test again. If the “Replace Battery” LED is still on, the 
battery needs to be replaced.

To Silence Audible Alarm 

While the Unit is in battery-backup mode, push the “ON/OFF/TEST” button for less 
than 1.5 seconds to silence the audible alarm. (This does not work if the Unit is in a 
OVERLOAD condition.)

All equipment must be powered off prior to plugging into the  
Unit (installation).

Connect the Phone/Fax/Modem Lines 

Connect a single phone/fax/modem line into the surge-protected outlets on 
the back of the Unit. The RJ11 modular outlet accepts standard single-line 
telephone connections. The connection will require another length of telephone 
cable (included).

NOTE: This connection is optional but highly recommended as phone/
fax/modem lines often carry dangerous surges and spikes. The Unit 
works properly without a phone/fax/modem connection.

Caution! 

The phone/fax/modem protection feature could be rendered 

inoperable if improperly installed. Make sure that the telephone line from 
the wall is plugged into the connector marked “IN”, and the device to be 
protected is plugged into the connector marked “OUT”.

Battery Replacement Procedure 

Replacement requires removing the battery cover plate on the back or 
bottom of the Unit. No tools are needed. To replace the batteries:

1.

   Press fastener to remove the battery cover plate on the back of the  

Unit (Fig. 1). 

2.

   Disconnect the insulated connectors from the battery terminals (Fig. 2).

3.

   Remove the battery, insert a new battery pack, and push the connectors 

onto the battery terminals (black-to-black and red-to-red) (Fig. 3).

 

NOTE:

 There may be a small spark at the battery terminals when 

reconnecting the connectors. This is normal and will not harm you  
or the Unit.

4.

   Close the battery cover (Fig. 1).

A. Surge-Protected-Only Outlets

 

Equipment such as a printer, fax machine, scanner, or a desk lamp can be 
plugged into these outlets. These outlets do not provide battery power 
during a outage. They are always on (when AC power is available) and are not 
controlled by the front-panel switch.

B. Battery-Backup Outlets

 

Only data-sensitive equipment such as a computer, monitor, and external drive 
should be plugged into these outlets. Battery power is automatically provided 
in case of a power outage. Power (AC or battery) is not supplied to these outlets 
when the Unit is switched off. (Do not plug surge protectors or power strips into 
the battery-backup outlets.)

 

Note! During the AVR Mode, the total load that you will be placing 
on the battery-backup outlets should not exceed 85% of the  
Unit’s capacity.

C. Phone/Fax/Modem Protection

 

The phone/fax/modem lines are surge-protected and provide complete 
safety for line connection. 

D. Interface Ports (USB & RS232) 

 

The Unit provides a USB port for use with your computer. 
For the F6C900-UNV, F6C1100-UNV, F6C1200-UNV model, the unit provides 
both a USB and RS232 port. 

NOTE: 

Choose one port only. 

E. AC Input Breaker (Circuit Breaker)

 

The circuit breaker button will be triggered if an overload condition 
forces the Unit to disconnect itself from utility power. If the button sticks 
out, disconnect nonessential equipment and depress breaker.

F. AC Input Power Cord

G. Site Wiring Fault Indicator

 

The “SITE WIRING FAULT” LED will illuminate when one of the following 
conditions exist:

 

1. Open or high-resistance ground

 

2. Hot and neutral polarity reversal

 

3. Overloaded neutral circuit

H. Audio Video Surge-Protection Port 

(Only F6B750-AVR)

I. Network Protection(F6C900-UNV/F6C1100-UNV/F6C1200-UNV)

 

This connector is used for protecting the transmission line of an Ethernet 
card from surges, noise, and spikes. 

TOP PANEL 

 

      REAR PANEL

Overview        Storage 

Storage Conditions

Store the Unit covered and upright in a cool, dry location with its battery fully 
charged. Before storing, charge the Unit for at least four (4) hours. Disconnect 
any cables connected to the computer interface port to avoid unnecessary 
drainage of the battery.

Extended Storage

During extended storage in environments where the ambient temperature 
is +5º F to +86º F, charge the Unit’s battery every six (6) months. During 
extended storage in environments where the ambient temperature is +86º F 
to +113º F, charge the Unit’s battery every three (3) months.

Note:

Please save this User Manual!

It contains important operating instructions and warranty information 
pertaining to your Battery Backup.

Please save or recycle the packaging materials!

The Unit’s packaging was designed with great care to provide 

protection during shipment and delivery. These materials are 

invaluable if you ever have to return the Unit for service. Damage 

sustained during transit is not covered under the warranty.

Overview   |   Top and Rear Panels