background image

PureAV 

Power 

Console

Belkin Connected Equipment Warranty

Belkin Limited warrants to the original consumer or other end-user of 
any PureAV Power Console for the life of the product, that the PureAV 
Power Console shall be free of defects in design, assembly, material 
or workmanship and will repair or replace, at its option, any defective 
PureAV Power Console free of charge. 

Belkin Limited will repair or replace, at its option, any equipment 
(“connected equipment”) that is damaged by a transient voltage  
surge/spike or lightning strike (an “Occurrence”), while properly 
connected through a PureAV Power Console to a properly wired power 
line with protective earth (the “Belkin Connected Equipment Warranty”). 
(For models AP20500xx3M, AP21000xx3M, AP41000xx3M, the 
telephone line and the coaxial cable must be properly connected  
and installed). 

This Belkin Connected Equipment Warranty is subject to the 
limitations and exclusions set forth herein. The warranties provided 
herein do not affect the consumer’s statutory rights under applicable 
national laws in force, nor the consumer’s rights against the retailer 
arising from its sales/purchase contract. 

Belkin will spend, to repair or replace the damaged connected 
equipment, at its option, an amount equal to the fair market value of the 
damaged equipment or the original purchase price of the equipment, 
whichever is the less, up to a maximum set forth below: 

For model AP20500xx3M (PF30), up to a maximum of 

E

200.000   

For model AP21000xx3M (PF40), up to a maximum of 

E

300.000 

For model AP41000xx3M (PF50), up to a maximum of 

E

400.000 

The fair market value of the equipment shall be the current retail market 
value of the same or similar model or specification as agreed by Belkin 
at the time it accepts or approves any claim. 

Belkin reserves the right to review the damaged PureAV Power Console, 
the damaged equipment, and the site where the damage occurred. 
All costs of shipping the PureAV Power Console and the damaged 
equipment to Belkin for inspection shall be borne initially by the 
purchaser. Belkin reserves the right to negotiate the cost of repairs. If 
Belkin determines, in its sole discretion, that it is impractical to ship 
the damaged equipment to Belkin, Belkin may designate, in its sole 
discretion, an equipment repair facility to inspect and estimate the cost 
to repair such equipment. The cost, if any, of shipping the equipment to 
such repair facility and of such estimate shall be borne initially by the 
purchaser. Damaged equipment must remain available for inspection 
until the claim is finalised. Whenever claims are settled, Belkin Limited 
reserves the right to be subrogated under any existing insurance policies 
the claimant may have. 

25

Summary of Contents for AP41000uk3M

Page 1: ...AP41000ea3M Home Cinema Power Protection with PureFilter Technology Power Console PF50 User Manual ...

Page 2: ...Step 5 Connect Digital Components to the Digital Filters 12 Step 6 Connect Video Components to the Video Filter 13 Step 7 Connect Audio Components to the Audio Filter 14 Step 8 Connect High Current Audio Filter 15 Step 9 Connect your Pay Per View Phone Line 16 Step 10 Connect your Cable TV Satellite Coaxial Lines 17 Step 11 Connect your Broadband Ethernet Line 18 Operation 19 Technical Specificati...

Page 3: ...vervoltage Protection which automatically disconnects power from your equipment when the input voltage reaches a dangerous level and restores power automatically when the voltage returns to a safe level We also realise that the aesthetics of your system are very important For this reason we enlisted some of the top industrial designers in the world to design the housing for the PureAV Power Consol...

Page 4: ... event of a lightning storm it is best to unplug your Power Console from the wall Once you have done this there is no need to unplug any of the equipment that is connected to the Power Console Warning Water and other Liquids Shock Hazard Do not use this product with aquariums or other water related products Use indoors and in dry locations only Do not operate the Power Console if any liquid is spi...

Page 5: ...treated as household waste By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please visit our web at www belkin com or contact your local city office your household wa...

Page 6: ...line noise and interference to your digital components dual stage digital filter 6 Video Filter ensures optimum reduction of line noise and interference to your video components single stage analog filter 7 Audio Filter ensures optimum reduction of line noise and interference to your audio components single stage analog filter 8 HiCurrent Filter delivers high current to power hungry amplifiers and...

Page 7: ...ects broadband Ethernet lines used for digital media receivers gaming or broadband Internet access from dangerous power surges 14 Cable TV Antenna and Satellite Line Input Output protects coaxial cable lines from dangerous electrical disturbances that can travel down your coaxial cable lines 15 13 Amp Circuit Breaker offers safety of resettable circuit breaker 16 Earth Screw provides an earthing p...

Page 8: ...Console for flush installation in the rack D Attach the bracket to the side of the Power Console Fig 1 You must use a minimum of four screws to mount each bracket E Repeat steps C and D for installation of the bracket to the other side of the Power Console F Mount the Power Console to the equipment rack Note Screws for mounting the Power Console to the equipment rack are not provided as they are m...

Page 9: ...s 10 11 These sockets will remain powered on for a short period of time after switching them off depending on the Delay Time setting see Delay Time Switch below C Socket Banks Switched On After Delay You may find it necessary to program your sockets to switch on after a delay Once the delay is set the sockets will be powered on after the sockets that are set for no delay have powered on They will ...

Page 10: ... accepts a 3 5mm jack cable Set the Trigger Out switch to Delayed and the trigger out function will power an external device after a delay set by the Delay Time switch Fig 2e If you do not want a delay set the Trigger Out switch to Switched Note This feature also allows you to remotely control multiple Power Consoles using a Remote DC Control Cable Simply connect the Cable from the DC OUT to the D...

Page 11: ...cluded Remote AC Control Cable into the Remote AC IN socket located on the back of the Power Console Fig 3a B Press the Remote button on the front of the Power Console to turn on the remote function The LCD display should read REMOTE ON Fig 3b C Press the Switched button on the front of the Power Console to turn off the switched sockets D Connect the Europlug male end of the Remote AC Control Cabl...

Page 12: ...C Control Cable included into the socket labeled DC IN on the rear panel of the Power Console Fig 4a B Press the Remote button on the front of the Power Console to turn on the remote function The LCD display should read REMOTE ON Fig 4b C Press the Switched button on the front of the Power Console to turn off the switched sockets D Connect the other end of the Remote DC Control Cable into the 3 30...

Page 13: ...igh current audio components A Attach PureAV power cable labels to each component s power cable before you plug the cable into the sockets on the Power Console B Connect the power cables of your digital components to any socket labeled under the Digital Filter Examples of the most common digital components are listed below 1 Digital Cable Satellite Signal Box 2 HDTV Digital Display 3 Digital Video...

Page 14: ...o and high current audio components A Attach PureAV power cable labels to each component s power cable before you plug the cable into the sockets on the Power Console B Connect the power cables of your video components to any socket labeled under the Video Filter Examples of the most common video components are listed below 1 TV Monitor 2 VCR 3 Analog Cable TV Set Top Box 4 Projector Note You can ...

Page 15: ...rrent audio components A Attach PureAV power cable labels to each component s power cable before you plug the cable into the sockets on the Power Console B Connect the power cables of your audio components to any socket labeled under the Audio Filter Examples of the most common audio components are listed below 1 Tape Player 2 Receiver Preamp 3 Turntables Note You can connect any type of audio com...

Page 16: ...turn off first avoiding that annoying and potentially damaging thump from getting to your speakers A Attach PureAV power cable labels to each component s power cable before you plug the cable into the HiCurrent socket on the Power Console B Connect your high current device into the HiCurrent Filter Examples of the most common high current components are listed below 1 Amplifiers 2 Powered Sub Woof...

Page 17: ...your telephone cable to the Power Console phone port labeled IN B Connect one end of the PureAV phone cable included to the Power Console phone port labeled OUT Connect the other end of this cable to the Pay Per View phone port on your cable TV or satellite receiver C To connect a telephone Connect one end of another phone cable to the other Power Console phone port labeled OUT Connect the other e...

Page 18: ...TV tuner B Cable TV Connect the incoming cable television F type coaxial cable line to the connector labeled Cable IN Connect one end of a second coaxial cable to the connector labeled Cable OUT Connect the other end of this cable to your cable TV set top box C Antenna Connect the incoming TV or radio antenna cable line to the connector labeled Antenna IN Connect one end of a second aerial cable t...

Page 19: ...5 network patch cable to a network port either directly to a router or wired network wall port Connect the other end of the network patch cable to the network port labeled IN B Connect one end of the broadband Ethernet cable included to the network port labeled OUT Connect the other end of this cable to the networked device digital media receiver gaming console etc Note We have included labels for...

Page 20: ...tton E Wiring indicates whether the AC socket to which the Power Console is connected is wired properly or cross wired Wiring OK Live and neutral wires are reversed See page 23 in the Troubleshooting section for more information F Earthed indicates if the Power Console is connected to a properly earthed AC socket Earth OK The AC wall socket is properly earthed Earth Fault This indicates that the A...

Page 21: ...with a front auxiliary power socket This socket contains a digital noise filter and is a convenient place to connect digital video cameras digital still cameras MP3 players game consoles or any other portable device in need of AC power Simply remove the small door covering the socket by sliding it to the right Fig 6 and plug in your device Note The auxiliary power socket is controlled by the Bank ...

Page 22: ...nsions mm 435 x 329 x 153mm LxWxH Number of Sockets 10 Programmable Sockets Cable Length 3M SD1000 Joule Rating 8750J Maximum Spike Current 300 000A Response Time 1 nanosecond Coaxial Protection 3 in 3 out Telephone Protection 1 in 2 out Ethernet Protection 1 in 1 out Overload Protection Yes Power Safety Shutdown 196Vac 6Vac 264Vac 6Vac ...

Page 23: ... Switched button on the front of the Power Console unit until the Switched ON indicator is illuminated You should now have power to all of the switched sockets Your components may not be turned on Power may be flowing from the Power Console but if the power switch on your component is not turned on your component cannot receive power Turn on your component s power switch The surge protection compo...

Page 24: ...ole is plugged into an earthed AC wall socket Do not use any plug adapters This indicates that the live and neutral L N wires are reversed Unplug the Power Console and consult an electrician For all other technical questions or troubleshooting issues please contact Belkin Customer Service on 00 800 22355460 ...

Page 25: ...ero voltage potential Common connecting points are earth rods or cold water pipes that are connected to the Earth Joule Rating A measure of electrical energy The higher the joule rating the more electrical surges a device can absorb before failing Maximum Spike Current The maximum current in Amps that can be absorbed before failing The higher the maximum spike current the more current a device can...

Page 26: ...to the fair market value of the damaged equipment or the original purchase price of the equipment whichever is the less up to a maximum set forth below For model AP20500xx3M PF30 up to a maximum of E200 000 For model AP21000xx3M PF40 up to a maximum of E300 000 For model AP41000xx3M PF50 up to a maximum of E400 000 The fair market value of the equipment shall be the current retail market value of ...

Page 27: ...s to consumers and the implied warranty of merchantability or fitness for a particular purpose In no event shall Belkin be liable for consequential or indirect losses including lost business loss of profits loss of service loss of software loss of information damage to any computer media other than hardware or damage to or loss of any property arising out of the sale or use of any PureAV Power Con...

Page 28: ...at was connected to the PureAV Power Console at the time of the Occurrence c The equipment that was damaged during the Occurrence and the extent of the damage d The date of the Occurrence e Where you purchased the PureAV Power Console f When you purchased the PureAV Power Console 3 Your Belkin Customer Service Representative will then instruct you on how to forward your equipment receipt PureAV Po...

Page 29: ...PureAV Power Console 28 ...

Page 30: ...hol Rijk The Netherlands 31 0 20 654 7300 31 0 20 654 7349 fax Belkin GmbH Hanebergstrasse 2 80637 Munich Germany 49 0 89 143405 0 49 0 89 143405 100 fax Belkin SAS 130 rue de Silly 92100 Boulogne Billancourt France 33 0 1 41 03 14 40 33 0 1 41 31 01 72 fax 2005 Belkin Corporation All rights reserved All trade names are registered trademarks of respective manufacturers listed P74976uk www pureav c...

Reviews: