background image

Hookup and Installation

PureAV 

Power 

Console

Step 2   
Remote AC Operation

This function allows you to turn your Power Console on and off via  
your preamplifier or receiver equipped with a switched European  
power socket.

Note:  

 You cannot turn off the switched sockets on the Power Console 
with the “Switched” button on the front of the unit when there  
is any external power signal supplied to either the AC or DC 
remote inputs.

To install the Remote AC Control Cable:

A. 

 Plug the C8 (Fig. 8 – female) end of the included Remote AC Control 
Cable into the “Remote AC IN” socket located on the back of the 
Power Console. (Fig. 2a)

B. 

 Press the “Remote” button on the front of the Power Console to turn 
on the remote function. The LCD display should read “REMOTE ON”. 
(Fig. 2b)

C. 

 Press the “Switched” button on the front of the Power Console to 
turn off the switched sockets.

D. 

 Connect the Europlug (male) end of the Remote AC Control Cable  
into a switched power socket on a preamplifier or receiver. When you  
turn on the receiver or preamplifier, the sockets on the Power 
Console that are programmed as “Switched” will be turned on 
immediately and the “Switched/Delayed” sockets will come on  
after an eight-second delay. 

8

Fig. 2a

����

Fig. 2b

Summary of Contents for AP21000uk3M

Page 1: ...AP21000uk3M Home Cinema Power Protection with PureFilter Technology Power Console PF40 User Manual ...

Page 2: ...omponents to the Digital Filter 10 Step 5 Connect Video Components to the Video Filter 11 Step 6 Connect Audio Components to the Audio Filter 12 Step 7 Connect High Current Audio Filter 8 Second Delay 13 Step 8 Connect your Pay Per View Phone Line 14 Step 9 Connect your Cable TV Satellite Coaxial Lines 15 Step 10 Connect your Broadband Ethernet Line 16 Operation 17 Technical Specifications 19 Trou...

Page 3: ...ction which automatically disconnects power from your equipment when the input voltage reaches a dangerous level and restores power automatically when the voltage returns to a safe level We also realise that the aesthetics of your system are very important For this reason we enlisted some of the top industrial designers in the world to design the housing for the PureAV Power Console The minimalist...

Page 4: ... event of a lightning storm it is best to unplug your Power Console from the wall Once you have done this there is no need to unplug any of the equipment that is connected to the Power Console Warning Water and other Liquids Shock Hazard Do not use this product with aquariums or other water related products Use indoors and in dry locations only Do not operate the Power Console if any liquid is spi...

Page 5: ...er cable in heavy foot traffic areas where it could create a trip hazard hallways doorways across room If the power cable is frayed ripped cut or damaged in any way please discontinue use immediately and refer to the warranty section of this User Manual for instructions Waste Handling or Recycling Power Console The use of the symbol indicates that this product may not be treated as household waste...

Page 6: ...ors the Power Console s vital functions 4 Digital Filter ensures optimum reduction of line noise and interference to your digital components dual stage digital filter 5 Video Filter ensures optimum reduction of line noise and interference to your video components single stage analog filter 6 Audio Filter ensures optimum reduction of line noise and interference to your audio components single stage...

Page 7: ...ial cable lines 10 Pay Per View Phone Line Input Output protects Pay Per View phone or DSL lines from dangerous power surges that can damage your equipment built in splitter turns one line into 2 11 Broadband Ethernet Input Output protects broadband Ethernet lines used for digital media receivers gaming or broadband Internet access from dangerous power surges 12 10 Amp Circuit Breaker offers safet...

Page 8: ...le for flush installation in the rack D Attach the bracket to the side of the Power Console Fig 1 You must use a minimum of four screws to mount each bracket E Repeat steps C and D for installation of the bracket to the other side of the Power Console F Mount the Power Console to the equipment rack Note Screws for mounting the Power Console to the equipment rack are not provided as they are made s...

Page 9: ...e included Remote AC Control Cable into the Remote AC IN socket located on the back of the Power Console Fig 2a B Press the Remote button on the front of the Power Console to turn on the remote function The LCD display should read REMOTE ON Fig 2b C Press the Switched button on the front of the Power Console to turn off the switched sockets D Connect the Europlug male end of the Remote AC Control ...

Page 10: ...Remote DC Control Cable included into the socket labeled DC IN on the rear panel of the Power Console Fig 3a B Press the Remote button on the front of the Power Console to turn on the remote function The LCD display should read REMOTE ON Fig 3b C Press the Switched button on the front of the Power Console to turn off the switched sockets D Connect the other end of the Remote DC Control Cable into ...

Page 11: ...o components A Attach PureAV power cable labels to each component s power cable before you plug the cable into the sockets on the Power Console B Connect the power cables of your digital components to any socket labeled under the Digital Filter Examples of the most common digital components are listed below 1 Digital Cable Satellite Signal Box 2 HDTV Digital Display 3 Digital Video Recorder DVR or...

Page 12: ...o and high current audio components A Attach PureAV power cable labels to each component s power cable before you plug the cable into the sockets on the Power Console B Connect the power cables of your video components to any socket labeled under the Video Filter Examples of the most common video components are listed below 1 TV Monitor 2 VCR 3 Analog Cable TV Set Top Box 4 Projector Note You can ...

Page 13: ...tal video and high current audio components A Attach PureAV power cable labels to each component s power cable before you plug the cable into the sockets on the Power Console B Connect the power cables of your audio components to any socket labeled under the Audio Filter Examples of the most common audio components are listed below 1 Tape Player 2 Receiver Preamp 3 Turntables Note You can connect ...

Page 14: ...n on last and turn off first avoiding that annoying and potentially damaging thump from getting to your speakers A Attach PureAV power cable labels to each component s power cable before you plug the cable into the HiCurrent socket on the Power Console B Connect your high current device into the HiCurrent Filter Examples of the most common high current components are listed below 1 Amplifiers 2 Po...

Page 15: ...your telephone cable to the Power Console phone port labeled IN B Connect one end of the PureAV phone cable included to the Power Console phone port labeled OUT Connect the other end of this cable to the Pay Per View phone port on your cable TV or satellite receiver C To connect a telephone Conanect one end of another phone cable to the other Power Console phone port labeled OUT Connect the other ...

Page 16: ...TV tuner B Cable TV Connect the incoming cable television F type coaxial cable line to the connector labeled Cable IN Connect one end of a second coaxial cable to the connector labeled Cable OUT Connect the other end of this cable to your cable TV set top box C Antenna Connect the incoming TV or radio antenna cable line to the connector labeled Antenna IN Connect one end of a second aerial cable t...

Page 17: ... to a network port either directly to a router or wired network wall port Connect the other end of the network patch cable to the network port labeled IN B Connect one end of the broadband Ethernet cable included to the network port labeled OUT Connect the other end of this cable to the networked device digital media receiver gaming console etc Note We have included labels for the Network IN and N...

Page 18: ...ubleshooting section for more information E Earthed indicates if the Power Console is connected to a properly earthed AC socket Earth OK The AC wall socket is properly earthed Earth Fault This indicates that the AC wall socket is NOT properly earthed See page 21 in the Troubleshooting section for more information F Switched Indicator shows whether the Switched sockets are switched ON or OFF G Time...

Page 19: ...socket This socket contains a digital noise filter and is a convenient place to connect digital video cameras digital still cameras MP3 players game consoles or any other portable device in need of AC power Simply remove the small door covering the socket by sliding it to the right Fig 4 and plug in your device Fig 4 ...

Page 20: ...ct Dimensions mm 435 x 329 x 153mm LxWxH Number of Sockets 10 Sockets Cable Length 3M SD1000 Joule Rating 7700J Maximum Spike Current 264 000A Response Time 1 nanosecond Coaxial Protection 3 in 3 out Telephone Protection 1 in 2 out Ethernet Protection 1 in 1 out Overload Protection Yes Power Safety Shutdown 196Vac 6Vac 264Vac 6Vac ...

Page 21: ...to the sockets on the Power Console Your components may be plugged into a Switched socket and the socket is not switched on Check to ensure that the Switched ON indicator on the Control Panel is illuminated If the light is not illuminated press the Switched button on the front of the Power Console unit until the Switched ON indicator is illuminated You should now have power to all of the switched ...

Page 22: ... consult an electrician to properly earth the socket If the socket is properly earthed and the Earth Fault indicator is still lit the Power Console may be malfunctioning Please call Belkin Customer Service for assistance Cross Wired indicator is lit WIRING Check to make sure that the Power Console is plugged into an earthed AC wall socket Do not use any plug adapters This indicates that the live a...

Page 23: ...ero voltage potential Common connecting points are earth rods or cold water pipes that are connected to the Earth Joule Rating A measure of electrical energy The higher the joule rating the more electrical surges a device can absorb before failing Maximum Spike Current The maximum current in Amps that can be absorbed before failing The higher the maximum spike current the more current a device can...

Page 24: ...ual to the fair market value of the damaged equipment or the original purchase price of the equipment whichever is the less up to a maximum set forth below For model AP20500uk3M PF30 up to a maximum of 150 000 For model AP21000uk3M PF40 up to a maximum of 200 000 For model AP41000uk3M PF50 up to a maximum of 300 000 The fair market value of the equipment shall be the current retail market value of...

Page 25: ...t as to consumers and the implied warranty of merchantability or fitness for a particular purpose In no event shall Belkin be liable for consequential or indirect losses including lost business loss of profits loss of service loss of software loss of information damage to any computer media other than hardware or damage to or loss of any property arising out of the sale or use of any PureAV Power ...

Page 26: ... that was connected to the PureAV Power Console at the time of the Occurrence c The equipment that was damaged during the Occurrence and the extent of the damage d The date of the Occurrence e Where you purchased the PureAV Power Console f When you purchased the PureAV Power Console 3 Your Belkin Customer Service Representative will then instruct you on how to forward your equipment receipt PureAV...

Page 27: ...Notes PureAV Power Console 26 ...

Page 28: ...nds 31 0 20 654 7300 31 0 20 654 7349 fax Belkin GmbH Hanebergstrasse 2 80637 Munich Germany 49 0 89 143405 0 49 0 89 143405 100 fax Belkin SAS 130 rue de Silly 92100 Boulogne Billancourt France 33 0 1 41 03 14 40 33 0 1 41 31 01 72 fax 2005 Belkin Corporation All rights reserved All trade names are registered trademarks of respective manufacturers listed P74978uk www pureav com ...