MP-Bus

L

ON

W

ORKS

®

t

UK24LON

Various sensors

Power supply and communication 

via 3 conductors only

IRC Control
for L

ON

W

ORKS

®

Communication 

via 2 conductors

3

Example 1: 

Connecting the actuators and sensors in the plant room 

of a central ventilation system to L

ON

W

ORKS

®

 via a UK24LON unit

Example 2: 

VAV-Control with a link to L

ON

W

ORKS

®

The  plant  room  of  a  central  ventilation  

system employing Belimo MFT(2)/MP ac-

tuators  (for  air  dampers  and  valves)  can 

be bus-linked to L

ON

W

ORKS

®

. A UK24LON 

unit  (MP/LON  Gateway)  is  used  to  link 

the  MP-Bus-capable  actuators  and  the  

sensors that are connected to them to the 

L

ON

W

ORKS

®

 system.

ENG

 · 

01.0

7· 

PDF · 

Subject to technical changes

i0387102

MP-Bus

p

L

ON

W

ORKS

®

p

t

t

t

UK24LON

Typical applications of the UK24LON

VAV  air  volume  controllers  for  supply  air 

and exhaust air employing VAV-Compact 

(LMV-D2-MP,  NMV-D2-MP  or  SMV-D2-

MP)  motorised  actuators  can  be  linked 

together via an MP-Bus. 

The  VAV  devices  and  the  sensors  con-

nected  to  them  (presence  and  tempera-

ture  sensors)  are  linked  to  L

ON

W

ORKS

®

  

through a UK24LON unit (MP/LON Gate-

way). The UK24LON provides the actua-

tor  functions  and  sensor  values  to  the 

L

ON

W

ORKS

®

  network  via  standardised 

network  variables  (SNVT).  The  actuator 

functions and sensor values can be link-

ed  via  the  SNVTs  to  the  IRC  individual 

room controller, which takes on the cont-

rol tasks for the individual room.

Summary of Contents for UK24LON

Page 1: ...2 4 5 6 UK 4 Product Information UK24LON Gateway MP LONWORKS UK24LON LONWORKS LONMARK UK24LON i0385102...

Page 2: ...sions 5 Complete MFT 2 MP assortment 5 Connecting MFT 2 MP actuators 6 Connecting sensors 6 MP Bus conductor lengths 7 Functional Profile 8 9 SNVT functions of the function objects 10 Operation Charac...

Page 3: ...nnected to them to the LONWORKS system ENG 01 07 PDF Subject to technical changes i0387102 MP Bus p LONWORKS p t t t UK24LON Typical applications of the UK24LON VAV air volume controllers for supply a...

Page 4: ...data UK24LON unit Power supply AC 24 V 50 60 Hz DC 24 V Functional range AC 19 2 28 8 V DC 21 6 28 8 V For wire sizing 3 VA without MFT 2 MP actuators connected Power consumption 1 5 W Connections LON...

Page 5: ...bject to technical changes d0096102 Damper actuators with or without safety function Actuators for characterised control ball valves with or without spring return function MP VAV devices Actuators for...

Page 6: ...eans of digitising the analogue signal from the sensor through the actuator so that it can be passed on to LONWORKS via the UK24LON unit Connecting passive sensors Pt1000 Ni1000 NTC Connecting active...

Page 7: ...ctuators can be connected to each network No special cable or terminating resistors are needed Conductor lengths are limited see below for methods of calculation by the total power rating of the MFT 2...

Page 8: ...ppropriate box and can be used for control and indicating pur poses MP VAV only Open Loop Sensor Object 1 One sensor can be connected to each MFT 2 MP actuator It can be either a passive resistance ty...

Page 9: ...SCPTmaxSendTime 49 SCPTsndDelta 27 UCPTadFunction 1 UCPTadTranformation 2 SCPTtrnsTblX 28 SCPTtrnsTblY 29 SCPTinvrtOut 16 Damper Actuator Object 8110 nviRelStpt SNVT_lev_percent nviActuatState SNVT_s...

Page 10: ...in LONMARK functional profile 8110 see www lonmark org nvoActualValue Actual value for actuator position 0 100 stroke nvoAbsAngle SNVT displays a constant value of 655 34 for a valve actuator this is...

Page 11: ...axSendTime 49 SCPTmaxRcvTime 48 SCPTminDeltaAngl 43 SCPTminDeltaFlow 47 SCPTactuatorType 41 SCPToemType 61 SCPTlocation 17 SCPTnomAngle 58 SCPTnomAirFlow 57 SCPTminSetpoint 53 SCPTmaxSetpoint 50 SCPTd...

Page 12: ...switch back and forth and in the case of globe valve actuators by pressing the S2 button The UK24LON unit will then be able to recognise and address the actuator This status is indicated by fast flas...

Page 13: ...Note By holding the button depressed for more than 2 seconds all addressed and responding actuators can be tested simultaneously No mechanical testing of actuators can be initiated at addresses that...

Page 14: ...14 Notes...

Page 15: ...15 Notes...

Page 16: ...tralia Austria Bahrain Belgium Bosnia Herzegovina Brazil Bulgaria Canada Chile Croatia Cyprus Czech Republic Denmark Egypt Estonia Finland France Great Britain Germany Greece Hong Kong Hungary Iceland...

Reviews: