background image

Technical data sheet

SF24A-MP

www.belimo.com

SF24A-MP • en-gb • 2020-12-14 • Subject to change

4 / 7

Mounting kit for linkage operation for flat and side installation

ZG-AFB

Hand crank 63 mm

ZKN2-B

Service tools Description

Type

Adapter for Service-Tool ZTH

MFT-C

Belimo PC-Tool, Software for adjustments and diagnostics

MFT-P

Service Tool, with ZIP-USB function, for configurable and communicative Belimo 
actuators, VAV controller and HVAC performance devices

ZTH EU

Electrical installation

Supply from isolating transformer.
Parallel connection of other actuators possible. Observe the performance data.

Wiring diagrams
AC/DC 24 V, modulating

Operation on the MP-Bus

Cable colours:
1 = black
2 = red
3 = white
5 = orange

Cable colours:
1 = black
2 = red
3 = white
5 = orange

Functions

Functions when operated on MP-Bus
Connection on the MP-Bus

MP-Bus Network topology

A) additional MP-Bus nodes (max. 8)

There are no restrictions for the 
network topology (star, ring, tree or 
mixed forms are permitted).
Supply and communication in one 
and the same 3-wire cable

• no shielding or twisting necessary
• no terminating resistors required

Connection of active sensors

Connection of external switching contact

A) additional MP-Bus nodes (max. 8)

• Supply AC/DC 24 V
• Output signal DC 0...10 V
  (max. DC 0...32 V)
• Resolution 30 mV

A) additional MP-Bus nodes (max. 8)

• Switching current 16 mA @ 24 V
• Start point of the operating range

 

must be parametrised on the MP 
actuator as 

 0.5 V

Summary of Contents for SF24A-MP

Page 1: ...erating range Y 2 10 V Input Impedance 100 k Operating range Y variable Start point 0 5 30 V End point 2 5 32 V Options positioning signal Open close 3 point AC only Modulating DC 0 32 V Position feed...

Page 2: ...raft or in any other airborne means of transport Outdoor application only possible in case that no sea water snow ice insolation or aggressive gases interfere directly with the device and that it is e...

Page 3: ...gnal A range of settings can be adapted using the PC Tool see MFT P documentation Accessories Gateways Description Type Gateway MP zu BACnet MS TP UK24BAC Gateway MP to KNX UK24EIB Gateway MP to Modbu...

Page 4: ...s AC DC 24 V modulating Operation on the MP Bus Cable colours 1 black 2 red 3 white 5 orange Cable colours 1 black 2 red 3 white 5 orange Functions Functions when operated on MP Bus Connection on the...

Page 5: ...ly 0 100 with positioner SG Minimum limit with positioner SG Follow up control position dependent Control with 4 20 mA via external resistor Functional check Caution The operating range must be set to...

Page 6: ...ts Override control and limiting with AC 24 V with rotary switch 1 Caution This function is only guaranteed if the start point of the operating range is defined as min 0 5 V Control open close Control...

Page 7: ...7 Dimensions Dimensional drawings Clamping range Min 85 Min 15 Further documentation Overview MP Cooperation Partners Tool connections Introduction to MP Bus Technology Application notes For digital...