background image

Technical data sheet

NM24A-MP

www.belimo.com

NM24A-MP • en-gb • 2020-12-14 • Subject to change

4 / 7

Shaft clamp reversible, clamping range Ø8...20 mm

K-NA

Ball joint suitable for damper crank arm KH8 / KH10

KG10A

Ball joint suitable for damper crank arm KH8

KG8

Damper crank arm Slot width 8.2 mm, clamping range Ø10...18 mm

KH8

Anti-rotation mechanism 180 mm, Multipack 20 pcs.

Z-ARS180

Base plate extension for NM..A to NM.., pcs.

Z-NMA

Position indicator, Multipack 20 pcs.

Z-PI

Form fit insert 10x10 mm, Multipack 20 pcs.

ZF10-NSA

Form fit insert 12x12 mm, Multipack 20 pcs.

ZF12-NSA

Form fit insert 15x15 mm, Multipack 20 pcs.

ZF15-NSA

Form fit insert 16x16 mm, Multipack 20 pcs.

ZF16-NSA

Form fit insert 8x8 mm, Multipack 20 pcs.

ZF8-NMA

Mounting kit for linkage operation for flat installation

ZG-NMA

Service tools Description

Type

Adapter for Service-Tool ZTH

MFT-C

Belimo PC-Tool, Software for adjustments and diagnostics

MFT-P

Service Tool, with ZIP-USB function, for configurable and communicative Belimo 
actuators, VAV controller and HVAC performance devices

ZTH EU

Electrical installation

Supply from isolating transformer.
Parallel connection of other actuators possible. Observe the performance data.

Wiring diagrams
AC/DC 24 V, modulating

Operation on the MP-Bus

Cable colours:
1 = black
2 = red
3 = white
5 = orange

Cable colours:
1 = black
2 = red
3 = white
5 = orange

Functions

Functions when operated on MP-Bus
Connection on the MP-Bus

MP-Bus Network topology

A) additional MP-Bus nodes (max. 8)

There are no restrictions for the 
network topology (star, ring, tree or 
mixed forms are permitted).
Supply and communication in one 
and the same 3-wire cable

• no shielding or twisting necessary
• no terminating resistors required

Summary of Contents for NM24A-MP

Page 1: ...nicative control MP Bus Operating range Y 2 10 V Input Impedance 100 k Operating range Y variable Start point 0 5 30 V End point 2 5 32 V Options positioning signal Open close 3 point AC only Modulati...

Page 2: ...solation or aggressive gases interfere directly with the device and that it is ensured that the ambient conditions remain within the thresholds according to the data sheet at any time Only authorised...

Page 3: ...osition defined by the positioning signal A range of settings can be adapted using the PC Tool see MFT P documentation Accessories Gateways Description Type Gateway MP zu BACnet MS TP UK24BAC Gateway...

Page 4: ...ration for flat installation ZG NMA Service tools Description Type Adapter for Service Tool ZTH MFT C Belimo PC Tool Software for adjustments and diagnostics MFT P Service Tool with ZIP USB function f...

Page 5: ...Functions with basic values conventional mode Override control with AC 24 V with relay contacts Override control with AC 24 V with rotary switch Control remotely 0 100 with positioner SG Minimum limi...

Page 6: ...relay contacts Override control and limiting with AC 24 V with rotary switch 1 Caution This function is only guaranteed if the start point of the operating range is defined as min 0 5 V Control open...

Page 7: ...rawings Clamping range Option Accessory K NA Option Shaft clamp mounted below accessories K NA needed Min 40 Min 20 Further documentation Overview MP Cooperation Partners Tool connections Introduction...