NFBUP, NFBUP-S, NFXUP, NFXUP-S

On/Off, Spring Return, 24 to 240 VAC

Accessories

AV 8-25

Shaft extension

IND-AFB

Damper position indicator

K7-2

Universal clamp for up to 1.05” dia jackshafts

KH-AFB

Crank arm

TF-CC US

Conduit fitting

Tool-06

8mm and 10 mm wrench

ZG-100

Universal mounting bracket

ZG-101

Universal mounting bracket

ZG-118

Mounting bracket for Barber Colman

®

 MA 3../4.., Honeywell

®

Mod III or IV or Johnson

®

 Series 100 replacement or new crank 

arm type installations

ZG-AFB

Crank arm adaptor kit 

ZG-AFB118

Crank arm adaptor kit

ZS-100 

Weather shield (metal)

ZS-150

Weather shield (polycarbonate)

ZS-260

Explosion-proof housing

ZS-300

NEMA 4X housing

Note:   When using NFBUP, NFBUP-S, NFXUP, NFXUP-S actuators, only use accessories listed on

this page.

For actuator wiring information and diagrams, refer to Belimo Wiring Guide.

Typical Specification

On/Off spring return damper actuators shall be direct coupled type which require
no crank arm and linkage and be capable of direct mounting to a jackshaft up to a
1.05” diameter. The actuators must be designed so that they may be used for either
clockwise or counterclockwise fail-safe operation.  Actuators shall be protected
from overload at all angles of rotation. If required, two SPDT auxiliary switch shall 
be provided having the capability of one being adjustable.  Actuators with auxiliary
switches must be constructed to meet the requirements for Double Insulation so 
an electrical ground is not required to meet agency listings.  Actuators shall be 
cULus Approved and have a 5 year warranty, and be manufactured under ISO 9001
International Quality Control Standards.  Actuators shall be as manufactured by 
Belimo.         

Wiring Diagrams

1

Provide overload protection and disconnect as required.

2

CAUTION 

Equipment Damage!

Actuators may be connected in parallel.
Power consumption and input impedance must be observed.

3

No ground connection is required.

4

For end position indication, interlock control, fan startup, etc., NFBUP-S and
NFXUP-S incorporates two built-in auxiliary switches:  2 x SPDT, 3A (0.5A) 
@250 VAC, UL Approved, one switch is fi xed at +10°, one is adjustable 10°
to 90°.

Meets cULus requirements without the need of an electrical ground con-
nection.

WARNING

 Live Electrical Components!

G

 During installation, testing, servicing and troubleshooting of this product, it may be

necessary to work with live electrical components.  Have a qualifi ed licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
 tasks. Failure to follow all electrical safety precautions when exposed to live electrical compo-
nents could result in death or serious injury.

NFBUP, NFBUP-S
NFXUP, NFBUP-S

W066_NFB

(X

)UP

On/Off wiring for NFBUP, NFXUP

Wht

Blk

NFBUP-S
NFXUP-S

W067_NFB

(X

)UP-S

Auxiliary Switches for NFBUP-S, NFXUP-S