that do not meet our quality standards (especially 

wind resistance, pipe diameter and number of ripples) 

shall not be used. If the warm air duct must withstand 

a considerable amount of bending immediately after the 

hot air outlet of the heater in a limited space, we 

recommend using a 90° elbow (Figu

re 3-37). This elbow 

can be connected to a diameter of mm hot air duct. 

 

 

 

 

 

In the case where the length of the pipe is less than 

2 meters, the air outlet cannot be installed at a 

height higher than the connection of the warm air 

duct. When the pipe length is less than 50cm,

 

the pipe 

must be siphon between the connector and the outlet. 

These measures prevent the undesirable heating caused 

by (fairing effect) convection of the vehicle during 

summer operation. 

★The warm air pipe must be firmly inserted

 into the 

connection port. 

To get the best warm air distribution, Belief 

recommends using 4 warm air outlets for the heater. 

If only three warm air outlets are required, then a 

lower warm air outlet must be selected to seal. 

★ The cross section of the heat

er duct must not be 

reduced due to pipe connections or the analogue. 

Gas Connection 

The heater operating pressure must be in compliance 

with a 30 Mbar liquefied gas supply. 

When the gas pipe is cut off, clean the port flash and 

burrs. 

The paving of the pipe must make the heater easy to 

disassemble for maintenance work. 

Use high-pressure air to purge internal debris before 

installing the gas pipe. 

The turning radius of the gas pipe is not less than 

R50, and it is recommended to use elbow pipe to pass 

the joint of right angle. 

 

 

★ The gas interface (Figure 13

-2) cannot be truncated 

or bent. 

Before connecting to the heater, make sure that the 

gas line is free of dirt, shavings, etc. 

The gas system must comply with the technical, 

administrative, and legal regulations of the country. 

Anti-collision safety valve (optional) 

To ensure safety during driving, it is recommended to 

install a crash safety valve that must be installed 

after the liquefied gas tank regulator. when Impact, 

tilting, the anti-collision safety valve automatically 

cuts off the gas line. 

 

 

 

 

 

 

Connecting Water Pipe 

The water tank can be supplied with a pressure pump or 

immersion pump with a pressure of 2.8 bar. 

If the tank is connected to a centralized water supply 

(rural or urban connection), or if a high-pressure 

pump is used, a pressure reducer must be used, which 

will prevent pressures above 2.8 bar. 

★ The temperature 

rises and expansion of the water 

before the pressure relief valve is triggered may 

Figure 12 

1  2 

Figure 13 

Figure 14 

To heater 

To liquefied gas 

pressure regulating 

valve 

Reset button 

Summary of Contents for 4W2005 12C11

Page 1: ...as Hot Water Warm Air Integrated Heater Technical Description Installation Operation and Maintenance Instructions Production Type Order No Liquefied gas electric heating DC12V 220VAC 4W2005 12C11 Version Oct 15 2018 ...

Page 2: ... users should know through the instructions If you have questions or find something wrong please contact us directly When the user unpacks for the first time check the main unit and accessories against the packing list If you find any problems please contact the dealer immediately If there is a problem in use please contact the company s marketing department or our authorized customer service stat...

Page 3: ...gas heating function is turned off first in the power adjustment phase In hot water working mode gas mode or electrical mode is used to heat the tank The tank temperature can be set to 40 C or 60 C Gas Mode The heater operates at the lowest power Stop heating immediately after reaching the set temperature Electrical Mode Manually select the 900W or 1800W heating mode according to the power supply ...

Page 4: ...es not bear any responsibility for the following acts Modified heater and accessories Modification of exhaust lines and accessories Do not follow the operating installation instructions Do not use our company s special accessories Figure 1 1 LCD control switch 2 External temperature sensor 3 Recirculating air inlet minimum 150cm2 4 Heat pipe 5 Heat outlet 6 Smoking cowl Figure 2 ...

Page 5: ...head self tapping nail M3 10 6_LCD control switch 7_Cross countersunk head flat tail self tapping nail M3 6 8_Cross head self tapping ST5 25 9_Heater 10_Controller cover 11_External temperature sensor lead wire 12_External temperature sensor 13_φ8 Elbow transition fitting 14_Rubber strip clamp 15_ Cross pan head self tapping screws ST5 16 16_φ8 Straight transition fitting 17_ Precision tube 18_ Fi...

Page 6: ... installed area there is no ventilation window in the range of 300mm and there is no refueling port or tank respirator in the range of 500mm The exhaust cowl is mounted below the window that is close to or openable A window switch should be installed to ensure that the heater is turned off automatically when the window is opened Air Inlet Hose Installation The exhaust pipe is pass through the inta...

Page 7: ...6 screws Figure 8 9 Use 2 screws to fix the exhaust cowl Fix the exhaust pipe on the side wall with mounting clip Connect Air Inlet Pipe to The Heater 20mm at the end of the exhaust pipe should be compressed do not straighten Try to insert the exhaust pipe on exhaust port as deep as possible fix the clip on top tighten Place the air intake pipe Figure 9 3 over the air inlet port Figure 9 5 Set on ...

Page 8: ...iquefied gas supply When the gas pipe is cut off clean the port flash and burrs The paving of the pipe must make the heater easy to disassemble for maintenance work Use high pressure air to purge internal debris before installing the gas pipe The turning radius of the gas pipe is not less than R50 and it is recommended to use elbow pipe to pass the joint of right angle The gas interface Figure 13 ...

Page 9: ...ternal temperature sensor should not be subjected to direct heat radiation For optimum room temperature control an external temperature sensor is installed above the entrance door Make sure the external temperature sensor is always installed on the vertical wall There must be free flowing air around it Drill a hole with a diameter of 10 mm Single wire terminal passes through the opening from the b...

Page 10: ... the housing with a cable tie to eliminate tension all cables must be securely connected and must not be loose or disconnected due to vibrations causing a fire hazard DC12V Power Supply the heater s electrical wiring switches and control equipment must be in locations that would not adversely affect its operation under normal operating conditions The heater has reverse polarity protection If the c...

Page 11: ...Belief 9 Figure 21 ...

Page 12: ... the overheat switch will immediately cut off the gas supply If the gas heater is to meet the heating needs during driving a safety shut off device should be installed If without a safety shut off device the liquefied gas tank valve must be shut off before the driving 12V Fuse replace only with the exact same fuse T10A 12V Fuse Fuse and Wire harness must be replaced by professionals authorized by ...

Page 13: ...ning liquefied gas tank valve Water tank filled with water when needed Switch Off the Heater Use a dedicated LCD switch to operate After the heater is turned off the combustion supporting fan and the heating fan will continue to operate for a few minutes depending on the temperature of the furnace In case of freezing hazard the water tank must be emptied Close the circulating water pump Turn on th...

Page 14: ...fault Check vehicle power supply system 11 Under voltage fault Check vehicle power supply system 21 Warm air outlet temperature sensor disconnection Check if the sensor is in good condition 22 Warm air outlet temperature sensor short circuit Check if the sensor is in good condition 23 Water temperature sensor disconnection Check if the sensor is in good condition 24 Water temperature sensor short ...

Page 15: ...tion air blower 82 Combustion support blower boot failure a Check the blower motor lead wire b Check combustion air blower 83 Combustion support blower spindle speed too low Check combustion air blower motor 84 Warm air blower motor disconnection Check warm air blower motor 85 Warm air blower motor boot failure Check the blower motor lead wire Check warm air blower motor 86 Warm air blower spindle...

Page 16: ...ells of gas Long term halt When the heater is not used for a long time it should be run every 4 weeks for about 10 minutes each time to prevent the mechanical components such as solenoid valves and combustion air fans from malfunctioning get stuck The air inlet and outlet of the heater must be kept free from clogging and dirt so that the warm air duct is unobstructed to prevent overheating Heater ...

Page 17: ...transition fitting 1C 14RN 1 12011103100 15 φ8 Elbow transition fitting 1C9 14RN 1 12011103200 16 φ10 Hose transition fitting φ10 1 12011103000 17 Hose water transition fitting 20411 16 06T 2 12011103300 18 φ10 Steel water pipe elbow transition fitting 1C9 16RN 2 12011103400 19 Nylon cable tie 4 200 10 21990000000 20 Intake and exhaust combine cowl φ110 108 1 12011101900 21 Intake and exhaust comb...

Page 18: ...Belief 16 ...

Page 19: ...rd Date Repaired Items and Reason Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year Month Day Year ...

Page 20: ...Science and Technology Co Ltd Phone 0451 82530666 0451 86676788 0451 86676988 Fax 0451 82537683 Address No 9 Xingnan Road Nangang District Harbin China E mail haoke sales bilaifu com Website www bilaifu com Postcode 150086 ...

Reviews: