![Belden ThinkLogical TLX320 Product Manual Download Page 25](http://html1.mh-extra.com/html/belden/thinklogical-tlx320/thinklogical-tlx320_product-manual_2725552025.webp)
Page 19
TLX320 Matrix Switch Product Manual
thinklogical
Rev. I, May 2021
Operating System Default Users
/
Passwords
TLX Matrix Switch Operating Systems:
Debian
7
Installed on V5.07.XX (and earlier)
➢
OS default username/password
debian/temppwd
root/root
Debian
8
Installed on V5.08.XX
➢
OS default username/password
debian/temppwd
root/root
(cannot remote into OS as root user)
Centos
7
Installed on V5.09.XX
➢
OS default username/password
centos/temppwd
root/root
(cannot remote into OS as root user)
Linux Command Console (Console)
•
Baud Rate: 115200
•
Data Bits: 8
•
Parity: none
•
Stop Bits: 1
•
Flow Control: none
•
DB9 DCE
➢
A straight (NOT a null-modem) cable is needed to connect to a PC.
ASCII API (RS-232) Settings
•
Baud Rate: 9600
•
Data Bits: 8
•
Parity: none
•
Stop Bits: 1
•
Flow Control: XON/XOFF (Software)
•
DB9 DCE
➢
A straight (NOT a null-modem) cable is needed to connect to a PC
Order of Installation Events
Please refer to the
Quick Start Guide
included with your products for detailed instructions. The
TLX320 Quick Start Guide
is also available in
Appendix A
,
pg.
26.
Firmware Updates
See
APPENDIX B: FPGA Program Code Update Procedure
,
pg.
27.
Firmware updates are available through Thinklogical
®
. For technical assistance, please call us at
1-203-647-8700
.
Note: If mounting the chassis in a rack, ensure that air flow to the fans is not restricted
(
minimum 2” of free space on all sides).
Note: If any of the sensors detect an over temperature condition, power will be removed
from all sensitive components and the system will shut down. All failure conditions send
out notifications prior to shut down. For a detailed list of the alarm functions, see pg. 4:
Alarm Descriptions for the TLX320
.