background image

 

 

25 

 

TLX Matrix Switch Interfaces

 

thinklogical

 

Rev. H 

 Jan. 2019

 

 

17600 

– System Data 

System data consists of 26 bytes. The first  5 bytes are the installed card inventory. A '0' bit means the 
card is installed and a '1' bit means the card is removed. 
The next 2 bytes have the current alarm contact settings. Each bit corresponds to a contact. Bit 0 (lsb) is 
the bit for the Power Supply 1 alarm, and bit 4 of byte 1 is the bit for the 'any' alarm. 
After  the  alarm  bytes,  the  next  byte  is  the  Backplane  Switch  Card  inventory,  '0'  meaning  the  card  is 
installed. 
The other bytes are for internal use.  

BIT  Byte 0 

Byte 1 

Byte 2 

Byte 3 

Byte 4 

Byte 8 

Byte 9 

Byte 10 

Card 1 

Card 9 

Card 17  Card 25 

Card 33 

Alarm 1 

Alarm 9 

Switch 1 

Card 2  Card 10 

Card 18  Card 26 

Card 34 

Alarm 2 

Alarm 10 

Switch 2 

Card 3  Card 11 

Card 19  Card 27 

Card 35 

Alarm 3 

Alarm 11 

Switch 3 

Card 4  Card 12 

Card 20  Card 28 

Card 36 

Alarm 4 

Alarm 12 

Switch 4 

Card 5  Card 13 

Card 21  Card 29 

Card 37 

Alarm 5 

Alarm 13 

Switch 5 

Card 6  Card 14 

Card 22  Card 30 

Card 38 

Alarm 6 

Switch 6 

Card 7  Card 15 

Card 23  Card 31 

Card 39 

Alarm 7 

Switch 7 

Card 8  Card 16 

Card 24  Card 32 

Card 40 

Alarm 8 

Switch 8 

Table 8: TLX1280 System Data 

 

17601:17640 

– Card Data 

Each I/O card in the Matrix Switch has an associated TCP port. Card 1 uses port 17601, card 2 
uses 17602, and so on. The data is formatted as follows: 

  16 bytes, internal use 

  2 bytes, card type (

other card types may be added in the future

 

0x12, 0x00

 

1280 10G 

  Signed 16-bits, card temperature (little-endian, bits 15-7) 

  example: 0x80 0x1d -> 0x1d80 -> 29.5°C 

  5 bytes, internal use 

  SFP data, 256 bytes per SFP, 32 SFPs per card 

  128 bytes, SFP ID data 

  128 bytes, SFP diagnostic data 

Summary of Contents for thinklogical TLX160

Page 1: ......

Page 2: ...All rights reserved Printed in the U S A Thinklogical A BELDEN BRAND 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 All trademarks and service marks are property of th...

Page 3: ...6 Standards with Which Our Products Comply 6 Supplementary Information 6 THE TLX SWITCH INTERFACES 7 Documentation 7 Byte Order for the Switch Connection Status Broadcast on Port 17564 7 Big Endian 7...

Page 4: ...nd NATO NIAPC Evaluation Scheme GREEN and the U S DoD DISA JITC UCR 2013 APL information assurance standards And Thinklogical Velocity products are the first system with both KVM and video matrix swit...

Page 5: ...he following fonts and colors are used throughout this document to help differentiate between file names commands outputs and document names lower upper case letter o and zero shown right Filenames Fo...

Page 6: ...all required domestic and many international requirements Regulatory Compliance Thinklogical s products are designed and made in the U S A These products have been tested by a certified testing labora...

Page 7: ...eographical regions and might not apply to your location This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la c...

Page 8: ...e Switch Connection Status Broadcast on Port 17564 Warning The 16 bit values documented here store the most significant byte first This is called Big Endian format For example a hexadecimal value of 1...

Page 9: ...s The primary CPU card will use address X and address X 100 The back up CPU will use address X 1 and it will take over address X in the event of a failure in the primary CPU The factory default value...

Page 10: ...f the switch Users should use the IP address in the data to identify which switch sent the message The data in the status block is stored in big endian format This means the MSB of the data is stored...

Page 11: ...nected Example c0 a8 0d 19 00 00 00 01 00 0c 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 12 0x000c Output 1 is connected to input 17 0x0011 Output 2 is connecte...

Page 12: ...removed The other bytes are for internal use ALARMS INVENTORY BIT Byte 0 Byte 1 0 PS Card 1 1 Fan 2 Temp 3 Card 4 5 6 7 Table 1 TLX12 System Data 17601 Card Data The I O card in the Matrix Switch is a...

Page 13: ...nected Example c0 a8 0d 19 00 00 00 01 00 18 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 24 0x0018 Output 1 is connected to input 17 0x0011 Output 2 is connecte...

Page 14: ...removed The other bytes are for internal use ALARMS INVENTORY BIT Byte 0 Byte 1 0 PS Card 1 1 Fan 2 Temp 3 Card 4 5 6 7 Table 2 TLX24 System Data 17601 Card Data The I O card in the Matrix Switch is a...

Page 15: ...nected Example c0 a8 0d 19 00 00 00 01 00 30 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 48 0x0030 Output 1 is connected to input 17 0x0011 Output 2 is connecte...

Page 16: ...ther bytes are for internal use ALARMS INVENTORY BIT Byte 0 Byte 1 0 Alarm 1 Card 1 1 Alarm 2 Card 2 2 Alarm 3 Card 3 3 Alarm 4 4 5 6 7 Table 3 TLX48 System Data 17601 17603 Card Data Each I O card in...

Page 17: ...8 0d 19 00 00 00 01 00 50 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 80 0x0050 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0x001...

Page 18: ...al use ALARMS INVENTORY BIT Byte 0 Byte 1 Byte 2 Byte 3 0 Alarm 1 0 Card 1 Card 9 1 Alarm 2 0 Card 2 Card 10 2 Alarm 3 0 Card 3 Card 11 3 Alarm 4 0 Card 4 Card 12 4 Alarm 5 0 Card 5 Card 13 5 Alarm 6...

Page 19: ...8 0d 19 00 00 00 01 01 A0 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 160 0x00A0 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0x00...

Page 20: ...l use ALARMS INVENTORY BIT Byte 0 Byte 1 Byte 2 Byte 3 0 Alarm 1 0 Card 1 Card 9 1 Alarm 2 0 Card 2 Card 10 2 Alarm 3 0 Card 3 Card 11 3 Alarm 4 0 Card 4 Card 12 4 Alarm 5 0 Card 5 Card 13 5 Alarm 6 0...

Page 21: ...0 a8 0d 19 00 00 00 01 01 40 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 320 0x0140 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0...

Page 22: ...Byte 2 Byte 3 Byte 4 0 Alarm 1 0 Card 1 Card 9 Card 17 1 Alarm 2 0 Card 2 Card 10 Card 18 2 Alarm 3 0 Card 3 Card 11 Card 19 3 Alarm 4 0 Card 4 Card 12 Card 20 4 Alarm 5 0 Card 5 Card 13 5 Alarm 6 0...

Page 23: ...0 a8 0d 19 00 00 00 01 02 80 00 11 00 12 IP address 192 168 13 25 Chassis 0 First Port number 1 Last Port number 640 0x0280 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0...

Page 24: ...Alarm 2 Alarm 10 Card 4 Card 20 Card 3 Card 19 Switch 2 2 Alarm 3 0 Card 6 Card 22 Card 5 Card 21 Switch 3 3 Alarm 4 0 Card 8 Card 24 Card 7 Card 23 Switch 4 4 Alarm 5 0 Card 10 Card 26 Card 9 Card 2...

Page 25: ...168 13 25 Chassis 0 First Port number 1 Last Port number 640 0x0280 Output 1 is connected to input 17 0x0011 Output 2 is connected to input 18 0x0012 Note The TXL1280 outputs status in two blocks The...

Page 26: ...d 26 Card 34 Alarm 2 Alarm 10 Switch 2 2 Card 3 Card 11 Card 19 Card 27 Card 35 Alarm 3 Alarm 11 Switch 3 3 Card 4 Card 12 Card 20 Card 28 Card 36 Alarm 4 Alarm 12 Switch 4 4 Card 5 Card 13 Card 21 Ca...

Page 27: ...Network Management Protocol The MIB Management Information Base definition files are located on the switch in the directory usr share snmp mibs The SNMP program may be configured by modifying the fil...

Page 28: ...n is enabled by entries in the rsyslog configuration file etc rsyslog conf or in configuration files located in etc rsyslog d The two log files with the most interesting information are var log daemon...

Page 29: ...lxcntl Output Ports Ports Function Program 17560 udp send LOS event tlxoobm network broadcast multicast 17564 udp send connection status tlxapi localhost only Option exists to restrict to localhost Ca...

Page 30: ...29 TLX Matrix Switch Interfaces thinklogical Rev H Jan 2019 Log files var log api var log messages var log daemon log var log tlxoobm log var log errors log var log snmpd log...

Page 31: ...Thinklogical is staffed Monday through Friday from 8 30am to 5 00pm Eastern Time Zone We will do our best to respond to your email inquiries promptly Please use the following email addresses info thin...

Page 32: ...he device or if you purchased directly call Thinklogical at 1 800 291 3211 USA Return Authorization If you must return a product to Thinklogical directly please contact us at 1 800 291 3211 or 1 203 6...

Reviews: