24
SPIDER II
Release 04 09/09
EMC and immunity
Network range
EMC interference immunity
IEC/EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
+/- 4 kV
+/- 8 kV
IEC/EN 61000-4-3
Electromagnetic field
80 - 2,700 MHz
20 V/m
IEC/EN 61000-4-4
Fast transients (burst)
DC power line
Data line
+/- 2 kV (2.5 kHz)
+/- 4 kV (2.5 kHz)
IEC/EN 61000-4-5
Voltage surges
DC power line, line / line
DC power line, line / earth
Data line, line / earth
+/- 1 kV
+/- 2 KV
+/- 1 kV
IEC/EN 61000-4-6
Line-conducted interference voltages
150 kHz - 80 MHz
10 V
EMC emitted interference
EN 55022
Class A
FCC 47 CFR Part
15
Class A
Stability
Vibration
IEC 60068-2-6, test Fc
5 Hz to 9 Hz with 3.5 mm amplitude;
1g at 9 Hz to 150 Hz;
1.5 g at 200 Hz to 250 Hz
IEC 60068-2-6, resonance search /
resonance dwell, test Fc
2 Hz to 13.2 Hz with 1 mm ampli-
tude;
0.7 g at 13.2 Hz to 100 Hz
Shock
IEC 60068-2-27 test Ea
15 g at 11 ms
TP port
Length of a twisted pair segment
max. 100 m / 300 ft (cat5e cable with 1000BASE-T)
Table 6: TP port 10BASE-T / 100BASE-TX / 1000BASE-T
Product code
SPIDER II 8TX/...
F/O
type
Wave
length
Fiber
System at-
tenuation
Expansion Fiber data
...FX EEC
...FX-ST EEC
MM
1300 nm
50/125 µm
0-8 dB
0-5 km
1.0 dB/km;
800 MHz*km
...FX EEC
...FX-ST EEC
MM
1300 nm
62.5/125 µm 0-11 dB
0-4 km
1.0 dB/km;
500 MHz*km
...FX-SM EEC
SM
1300 nm
9/125 µm
0-16 dB
0-30 km
0.4 dB/km;
3.5 ps/(nm*km)
Table 7: F/O port 100BASE-FX
Summary of Contents for Hirschmann SPIDER II 8TX
Page 27: ...27 SPIDER II Release 04 09 09 ...
Page 29: ......