Installation RSP20/25/30/35
Release 18 09/2021
57
f.
When using supply voltage with characteristic value CC, K9 or KK:
- applies when device is equipped with max. 4 SFP transceivers
- if a higher number is connected, the following maximum values apply for the ambient air
temperature: 5 to 7 transceivers: +176 °F (+80 °C)
When using supply voltage with characteristic value TT:
- applies when device is equipped with max. 2 SFP transceivers
- if a higher number is connected, the following maximum values apply for the ambient air
temperature: 4 transceivers: +176 °F (+80 °C); 5 ... 7 transceivers: +167 °F (+75 °C)
Summary of Contents for HIRSCHMANN RSP20