![Belden HIRSCHMANN RSP20 User Manual Download Page 25](http://html.mh-extra.com/html/belden/hirschmann-rsp20/hirschmann-rsp20_user-manual_2725683025.webp)
Installation RSP20/25/30/35
Release 18 09/2021
25
17
Temperature range
S
Standard
+32 °F ... +140 °F (0 °C ...
+60 °C)
T
Extended
-40 °F ... +158 °F (-40 °C ...
+70 °C)
E
Extended with
Conformal Coating
-40 °F ... +158 °F (-40 °C ...
+70 °C)
18 ... 19 Supply voltage
CC
2 voltage inputs for redundant power supply
Rated voltage range DC:
24 V DC ... 48 V DC
K9
1 voltage input
Rated voltage range AC:
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Rated voltage range DC:
60 V DC ... 250 V DC
KK
2 voltage inputs for redundant power supply
Rated voltage range AC:
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Rated voltage range DC:
60 V DC ... 250 V DC
TT
2 voltage inputs for redundant power supply
Rated voltage range DC:
12 V DC ... 24 V DC
20 ... 21 Certificates and
declarations
You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See table 5 on page 26.
22 ... 23 Customer-specific
version
HS
Hirschmann Standard
HM
Hirschmann Fast MRP
HP
Hirschmann PRP
HH
Hirschmann HSR
HD
From software version 05.0 onward:
Hirschmann DLR
Note:
You can exchange software with each other on the
following device variants:
HM
HP
HH
24
Software
configuration
E
Entry (without configuration)
25 ... 26 Software level
2S
HiOS Layer 2 Standard
2A
HiOS Layer 2 Advanced
3S
HiOS Layer 3 Standard
27 ... 31 Software version
02.0.
Software version 02.0
XX.X.
Current software version
Item
Characteristic
Character
istic value
Description
Table 4:
Device name and product code
Summary of Contents for HIRSCHMANN RSP20