5. Technical data

General data

Operating voltage

NEC Class 2 power source 24 V DC (-25% +33%) safety extra-low voltage (SELV) 
(redundant inputs decoupled), 5 A maximum

Buffer time

min. 10 ms at 24 VDC

Potential difference between input

Potential difference to input voltage, +24 VDC: 32 V DC

voltage and housing

Potential difference to input voltage, ground: -32 V DC

Current consumption at 24 VDC

7.0 W maximum; 24 Btu (IT)/h

Overload current protection at input

non-changeable fuse

Dimensions W x H x D

47 mm x 135 mm x 111 mm 

1.9 in x 5.3 in x 4.4 in

Weight

230 g 

5.07 lb 

Ambient temperature

Surrounding air: 0 ºC to + 60 ºC

32 ºF to 140 ºF

Storage temperature

Surrounding air: - 20 ºC to + 80 ºC

-4 ºF to 176 ºF

Humidity

up to 95% (non condensing)

Atmospheric pressure

up to 2000 m (795 hPa, higher altitudes on demand)

Protection type

IP 20

EMC interference proof

Discharge of static electricity

Contact discharge

EN 61000-4-2 Test level 3

Air discharge

EN 61000-4-2 Test level 3

Electromagnetic fields

EN 61000-4-3 Test level 3

Fast transients

EN 61000-4-4 Test level 3

Surge voltage symmetrical

EN 61000-4-5 Test level 2

Surge voltage asymmetrical

EN 61000-4-5 Test level 3

Cable-based RF faults

EN 61000-4-6 Test level 3

EMC emitted immunity

EN 55022

Class A

CFR-47 Part 15

Class A

Germanischer Lloyd

Rules for Classification and Construction VI - 7 - 3 Part 1

Stability

Vibration

IEC 60068-2-6 Test FC, testing level in line with IEC 61131-2 
Germanischer Lloyd Guidelines for the Performance of Type Tests Part 1

Shock

IEC 60068-2-27 Test Ea, testing level in line with IEC 61131-2 

Network size

TP/TX port 10BASE-T/100BASE-TX

Length of a twisted pair segment

100 m (328 ft) maximum

Interfaces

8 TP/TX ports 

RJ45 sockets, 10/100 MBit/s

Indicator contact

1 A maximum, 24 V

Displays

Equipment status

1 x green LED 

P1

– power 1, supply voltage 1 present

1 x green LED 

P2

– power 2, supply voltage 2 present

1 x red LED 

FAULT

– indicator contact is open and indicates error

Port status

8 x green/yellow LED

DAT/STAT 1 to 8

– data, link status

Controls

8-pole DIP switch 

LA1 to LA8

– suppress message about the link statuses

Scope of delivery

Rail Switch RS2-TX incl.

terminal block for supply voltage
description and operating instructions

Order number

Rail Switch RS2-TX

943 686-003

Accessories

Ethernet manual

943 320-011

Manual
Basics Industrial ETHERNET and TCP/IP

280 720-834

Rail Power Supply RPS 30

943 662-003

Rail Power Supply RPS 60

943 662-001

Rail Power Supply RPS 120

943 662-011

Summary of Contents for Hirschmann RS2-TX

Page 1: ...standard 802 3 using copper technolo gy The switch modules are plugged onto the standard bar The RS2 TX modules have eight 10 100 MBit s twisted pair ports RJ45 connectors It is possible to connect up...

Page 2: ...components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must...

Page 3: ...Li LCable and b max Cable Length Ca Ci CCable The lower value of a and b is to apply CableL inductance per unit length of used cable CableC capacitance per unit length of used cable Other C parameters...

Page 4: ...structions This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions z Warning Failure to ob...

Page 5: ...voltage 2 less than 9 6 V FAULT Failure red LED lit The indicator contact is open i e it indicates an error not lit The indicator contact is closed i e it does not indicate an error Port Status These...

Page 6: ...onnect up to eight data ter minal equipments DTE or other network segments to the 10 100 Mbit s ports of the RS2 TX using twisted pair cabling ref Fig 4 3 Assembly startup procedure and dismantling 3...

Page 7: ...61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 EMC emitted immunity EN 55022 Class A CFR 47 Part 15 Class A Germanischer Lloyd Rules for Classification and Construction VI 7 3...

Page 8: ...Automation and Control GmbH Stuttgarter Stra e 45 51 72654 Neckartenzlingen Germany Tel 49 0 1805 14 1538 Fax 49 0 7127 14 1551 E mail hac support belden com Internet http www hirschmann com 039 663 0...

Reviews: