6
3.3 STARTUP PROCEDURE
䡺
You start up the RS2-TX by connecting
the supply voltage via the 5-pin terminal
block.
3.4 DISMANTLING
䡺
To take the RS2-TX off the ISO/DIN rail,
insert a screwdriver horizontally under the
housing into the locking slide, pull it (with-
out tipping the screwdriver) downwards
and lift the RS2-TX upwards.
4. Further support
In the event of technical queries, please talk
to the Hirschmann contract partner respon-
sible for looking after your account or direc-
tly to the Hirschmann office. You can find
the addresses of our contract partners on
the Internet
http://www.hirschmann.com
You can contact us
in the EMEA region at
Tel.: +49 (0)1805 14-1538
E-mail: [email protected]
in the America region at
Tel.: +1 (717) 217-2270
E-mail: [email protected]
in the Asia-Pacific region at
Tel.: + 65 6854 9860
E-mail: [email protected]
www.hicomcenter.com gives you an up-to-
date overview of training courses about
technology and products.
2. Configuration
2.1 CONNECTING DTE AND OTHER
NETWORK SEGMENTS
It is possible to connect up to eight data ter-
minal equipments (DTE) or other network
segments to the 10/100 Mbit/s ports of the
RS2-TX using twisted pair cabling (ref. Fig.
4).
3. Assembly, startup procedure
and dismantling
3.1 UNPACKING, CHECKING
䡺
Check whether the package was deliver-
ed complete (see scope of delivery).
䡺
Check the individual parts for transport
damage.
z
Warning!
Use only undamaged parts!
3.2 ASSEMBLY
The equipment is delivered in a ready-to-
operate condition. The following procedure
is appropriate for assembly:
䡺
Check whether the switch pre-setting
suits your requirements (see chap. 1.5).
䡺
Pull the terminal block off the RS2-TX
and wire up the supply voltage and indica-
tor lines.
䡺
Fit the RS2-TX on a 35 mm standard bar
to DIN EN 50 022.
䡺
Attach the upper snap-on slide bar of
the RS2-TX to the standard bar and press it
down until it locks in position.
䡺
Fit the signal lines.
Notes:
– The front panel of the RS2-TX is grounded
via a separate ground connection.
– Do not open the housing.
– The shielding ground of the twisted pair
lines which can be connected is electrical-
ly connected to the front panel.
RS2-TX
Fig. 4: Configuration with RS2-TX: Connection of up to 8 data terminal
equipments or further segments via TP/TX
Fig. 6: Assembling the RS2-TX