background image

Description and operating instructions
Industrial Ethernet Rail Switch 2

RS2-TX

Order No. 

943 686-003

The Rail Switch RS2 has been especially
designed for use in industrial environments.
It supports ETHERNET 10 MBit/s and Fast
ETHERNET 100 MBit/s.

The Rail Switch modules support switched
ETHERNET networks in accordance with
IEEE standard 802.3 using copper technolo-
gy. The switch modules are plugged onto
the standard bar.

The RS2-TX modules have eight 10/100
MBit/s twisted pair ports (RJ45 connectors).

It is possible to connect up to eight data ter-
minal equipments or other network seg-
ments to the 10/100 Mbit/s ports using twi-
sted pair cabling. The ports support auto
negotiation, autopolarity and autocrossing.

5

RS2-TX

+24V

+24V*

FA

UL

T

LA1

LA

3

LA2

LA4

LA5

LA6

0 1

6

7

8

DA/STAT

1

3

2

4

6

8

5

FAULT

1

2

LA7

LA8

7

P

1

2

3

4

Hirschmann. Simply a good Connection.

Summary of Contents for Hirschmann RS2-TX

Page 1: ...standard 802 3 using copper technolo gy The switch modules are plugged onto the standard bar The RS2 TX modules have eight 10 100 MBit s twisted pair ports RJ45 connectors It is possible to connect up...

Page 2: ...components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must...

Page 3: ...Li LCable and b max Cable Length Ca Ci CCable The lower value of a and b is to apply CableL inductance per unit length of used cable CableC capacitance per unit length of used cable Other C parameters...

Page 4: ...structions This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions z Warning Failure to ob...

Page 5: ...voltage 2 less than 9 6 V FAULT Failure red LED lit The indicator contact is open i e it indicates an error not lit The indicator contact is closed i e it does not indicate an error Port Status These...

Page 6: ...onnect up to eight data ter minal equipments DTE or other network segments to the 10 100 Mbit s ports of the RS2 TX using twisted pair cabling ref Fig 4 3 Assembly startup procedure and dismantling 3...

Page 7: ...61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 EMC emitted immunity EN 55022 Class A CFR 47 Part 15 Class A Germanischer Lloyd Rules for Classification and Construction VI 7 3...

Page 8: ...Automation and Control GmbH Stuttgarter Stra e 45 51 72654 Neckartenzlingen Germany Tel 49 0 1805 14 1538 Fax 49 0 7127 14 1551 E mail hac support belden com Internet http www hirschmann com 039 663 0...

Reviews: