26
Installation RED25
Release 01 02/2015
2.5
Operating the device
Note:
The torque for tightening the supply voltage terminal block on the
device is 4.5 lb-in (0.51 Nm).
Mount the terminal block for the supply voltage and the signal contact
using screws.
Enable the supply voltage.
2.6
Connecting data cables
In general, adhere to the following recommendations for data cable connec-
tions in environments with high electrical interference levels:
Keep the length of the data cables as short as possible.
Use optical data cables for the data transmission between the buildings.
When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in
separate cable channels.
Use shielded cables (SF/UTP cables as per ISO/IEC 11801:2002).
Connect the data cables according to your requirements.
For further information see
.
2.7
Filling out the inscription label
The information field for the IP address helps you identify your device.
WARNING
ELECTRIC SHOCK
Connect only a supply voltage that corresponds to the type plate of your
device.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.