background image

Applies to devices that are delivered with an unique default password that is located

on a label on the device

Perform the following steps:

1. Open the web interface the first time you log on to the device.

2. Type in the user name “admin”.

3. Type in the unique default password that is located on a label (“Def. password”) on the

device.

4. Click the “Login” button. After successfully entering the login information you have access

to the router using the Internet browser.

5.

To help maintain the security of your network, change the unique default password
of the router.

Some features may be disabled until you change the unique default password.

The unique default password will be applied again if you reset the router by the “Reset” button.

You find a detailed description of the router settings in the Web interface in the "User Manual
Configuration OWL 4G Family".You can download the PDF on the Internet at:

https://www.

doc.hirschmann.com/

.

UM Installation OWL LPWAN

Release 02 - 02/2020

35

Summary of Contents for HIRSCHMANN OWL LPWAN

Page 1: ...User Manual Installation Industrial Cellular Router OWL LPWAN UM Installation OWL LPWAN Release 02 02 2020 Technical support https hirschmann support belden com...

Page 2: ...ing only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann...

Page 3: ...hernet Port ETH0 and ETH1 26 6 6 4 Antenna Connector ANT 27 6 6 5 Reset Button 28 6 7 Description of the Left Panel 30 6 7 1 SIM Card Reader 31 6 7 2 Serial Interfaces and I O Port 32 7 First Use 34 7...

Page 4: ...11 Further Support 43 4 UM Installation OWL LPWAN Release 02 02 2020...

Page 5: ...osition of DIN rail clip 22 9 Removing from the DIN rail 22 10 The front panel of the router 23 11 Power connector 25 12 Connection of power supply 25 13 Ethernet connector 26 14 Connection of Etherne...

Page 6: ...hernet connector 26 8 Overview of router reboot and reset 29 9 Description of the left panel 30 10 Connection of RS485 32 11 Connection of I O 32 12 Connection of RS232 32 13 Basic parameters 37 14 St...

Page 7: ...on regarding user safety Note Problems that can arise in specific situations Information Useful tips or information of special interest Example Example of function command or script UM Installation OW...

Page 8: ...unc tioning device turn off the supply voltage and return the device to Hirschmann for inspection X Only routers with appropriate certification and labelling should be used in locations where flammabl...

Page 9: ...for personnel X Only allow qualified personnel to work on the device Qualified personnel have the following characteristics X Qualified personnel are properly trained Training as well as practical kn...

Page 10: ...connected to the grounding connector as a conductor X Beware of possible short circuits when connecting a cable section with conductive shielding braiding Data backup X It is recommended that you crea...

Page 11: ...d and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If thi...

Page 12: ...e display and the other information that you need to install the device Documentation mentioned in the User Manual Installation that is not supplied with your device as a printout can be found as PDF...

Page 13: ...power backup maximum 15 seconds depending on technology which is used to complete the run ning operation or to send the required data immediately after failure of power supply Configuration of the ro...

Page 14: ...elematic telemetric remote monitoring vending and dispatcher machines 4 1 Usage of the Router The router is primarily intended for these four basic situations I Access to the Internet from LAN Figure...

Page 15: ...cked up access to the Internet from LAN Figure 2 Backed up access to the Internet III Secure networks interconnection or using VPN Figure 3 Using VPN tunnel UM Installation OWL LPWAN Release 02 02 202...

Page 16: ...IV Serial Gateway Figure 4 Serial Gateway 16 UM Installation OWL LPWAN Release 02 02 2020...

Page 17: ...cs 3 Wing on wall mounting screwed on the router 2 pcs 4 2 pin terminal block for power supply deployed on the router 1 pcs 5 10 pin terminal block for RS232 RS485 and I O deployed on the router 1 pcs...

Page 18: ...plied in the following versions see table below All versions are available in a metal box Router versions SIM BIN BOUT ETH RS232 RS485 OWL LPWAN 2 x 1 x 1 x 2 x 1 x 1 x Table 2 Router versions Figure...

Page 19: ...the table below Product type Product name Order code Features interfaces OWL 4G OWL LPWAN 942 286 001 LTE module for NAM 2x ETH 1x BI 1x BO 1x RS232 1x RS485 2x SIM reader Table 3 Order Codes Overview...

Page 20: ...6 3 Basic Dimensions of the Router Box specified in mm Figure 6 Basic dimensions of the router box Figure 7 Basic dimensions of the router box 20 UM Installation OWL LPWAN Release 02 02 2020...

Page 21: ...a DIN rail EN 60715 with the included metal DIN rail clip If the negative pole of the router is grounded there is no protection against reversed polarity The only protection left is the fuse inside th...

Page 22: ...back or bottom When changing the position of the DIN rail clip tighten the screws with max 0 4 Nm torque Figure 8 Default position of DIN rail clip To remove the router from the DIN rail it is necessa...

Page 23: ...lt configuration and re boot the router PWR 2 pin Terminal block for the power supply ETH0 RJ45 Ethernet connection to the computer network ETH1 RJ45 Ethernet connection to the computer network ANT SM...

Page 24: ...On Fast blinking SIM is selected router waits for data connection 4G technology 2G technology SIM card problem missing SIM card or PIN code not entered SIM2 Green Green Red Red Blinking On On Fast bli...

Page 25: ...ce Only the service center can restore the router s functionality For correct operation it is necessary that the power source is able to supply a peak current of 1 2 A Unit has to be supplied by a pow...

Page 26: ...TXD Transmit Data positive pole Input Output 2 TXD Transmit Data negative pole Input Output 3 RXD Receive Data positive pole Input Output 4 5 6 RXD Receive Data negative pole Input Output 7 8 Table 7...

Page 27: ...can not operate without a main antenna connected through the port marked as ANT The SMA connector is used for the connection of the antenna Recommended tightening mo ment for screwing the antenna to...

Page 28: ...configuration turn off the router power supply Push and hold the RST button turn on the router and hold the RST button for at least 10 seconds This will return the router to default configuration Befo...

Page 29: ...s the Reboot menu item in the Web interface Press the RST button hold less than 4 seconds Reset factory Restores the default configuration and reboots the router Hold the RST button for more than 4 se...

Page 30: ...rd and to the negative pole of the power source SIM cards 2FF size Unscrew the SIM cards cover to access the SIM1 and SIM2 slots SERIAL I O 10 pin This connector has the RS232 and RS485 serial inter f...

Page 31: ...SIM card Always disconnect the router from power supply before handling the SIM card Unscrew the SIM card cover Using a plastic opening tool or your fingernail press the SIM card slightly into its slo...

Page 32: ...IN OUT 3 GND GROUND Table 10 Connection of RS485 Pin Signal mark Description 4 BIN BINARY IN 5 BOUT BINARY OUT Table 11 Connection of I O Pin Signal mark Description 6 RXD IN 7 CTS IN 8 GND GROUND 9 R...

Page 33: ...e functional scheme of connection for the binary input and binary output is drawn on the picture below Figure 20 Functional scheme of the binary interface UM Installation OWL LPWAN Release 02 02 2020...

Page 34: ...he web interface This is described in detail in the Configuration OWL 4G Family user manual that you can download at https www doc hirschmann com 7 3 Configuration If no SIM card is inserted in the ro...

Page 35: ...ogin information you have access to the router using the Internet browser 5 To help maintain the security of your network change the unique default password of the router Some features may be disabled...

Page 36: ...tance of the closed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually working on improving and developing their software Check...

Page 37: ...of protection IP30 Supply voltage 9 to 36 V DC Battery for RTC CR1225 Consumption Idle Average Peak Sleep mode 2 5 W 4 W 11 W 0 085 W Dimensions of device 31 2 x 94 x 129 mm DIN rail clip dimensions D...

Page 38: ...tions Standards and regulations Radio PTCRB EMC FCC 15 107 Class B FCC 15 109 Class B IC Transportation EN 45545 2 Carrier approvals Verizon AT T National FCC IC Environmental REACH RoHS3 and WEEE com...

Page 39: ...Power ports 1 kV crit A shielded cab 0 5 kV crit A RF conducted EN 61000 4 6 All ports 10 V m crit A 0 15 80 MHz Radiated emission EN 55032 Enclosure Class B Conducted emission EN 55032 DC power ports...

Page 40: ...bps DL 375 Kbps UL EDGE parameters Supported frequencies 850 MHz 900 MHz 1800 MHz 1900 MHz EDGE bit rates 296 Kbps DL 236 8 Kbps UL GPRS parameters Supported frequencies 850 MHz 900 MHz 1800 MHz 1900...

Page 41: ...l parameters CPU power 2 DMIPS per MHz Flash memory Available memory space 1862 MB 2x 256 MB FW 512 MB User data storage 838 MB Space for User Modules RAM 512 MB Table 17 Other technical parameters UM...

Page 42: ...onfiguration user manual Application Notes and documentation of several OWL user modules can be found as PDF files for downloading on the Internet at https www doc hirschmann com 42 UM Installation OW...

Page 43: ...on three counts with its com plete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offe...

Page 44: ......