1.2.2
Power supply modules
Item
Characteristic Characte-
ristic value
Description
1 ... 3
Product
GPS
GREYHOUND
Power supply module
4
Type
1
Standard
Power supply for basic
device
3
PoE (+) basic device
Power supply for basic
device and PoE(+)
5
(hyphen)
–
6
Rated voltage
range
C
Rated voltage range
24 V DC ... 48 V DC
K
Rated voltage range
60 V DC ... 250 V DC
Rated voltage range
110 V AC ... 240 V AC, 50 Hz ... 60 Hz
P
Rated voltage range
48 V DC (PoE) ... 54 V DC (PoE+)
7
Temperature
range
S
Standard
+32 °F ... +140 °F
(0 °C ... +60 °C)
C
Standard with Conformal
Coating
+32 °F ... +140 °F
(0 °C ... +60 °C)
T
Extended
-40 °F ... +158 °F
(-40 °C ... +70 °C)
E
Extended with Conformal
Coating
-40 °F ... +158 °F
(-40 °C ... +70 °C)
8 ... 9
Certificates and
declarations
You will find detailed information on the certificates and declarations
applying to your device in a separate overview.