48
Installation BAT867-F
Release 01 12/2019
10.7
Network range
10.8
Power consumption/power output
EN 61000-4-3
Electromagnetic field
80 MHz ... 1000 MHz
10 V/m
1400 MHz ... 2700 MHz
10 V/m
EN 61000-4-4
Fast transients (burst)
DC power line
±2 kV
Data line
±4 kV
EN 61000-4-5
Voltage surges
DC power line
±1 kV line/ground; ±0.5 kV
line/line
Data line, shielded
±2 kV line/ground
EN 61000-4-6
Conducted disturbances
150 kHz ... 80 MHz
10 V
EMC interference
emission
EN 55032
Class A
Immunity
IEC 60068-2-6, test Fc
Vibration
5 Hz ... 8.4 Hz with 0.14 in (3.5 mm)
amplitude
8.4 Hz ... 150 Hz with 1 g
IEC 60068-2-27, test Ea
Shock
15 g at 11 ms
10/100/1000 Mbit/s twisted pair port
Length of a twisted pair segment
max. 328 ft (100 m) (for Cat5e cable)
Table 15: Network range: 10/100/1000 Mbit/s twisted pair port
Power consumption
Power output
9 W
31.0 Btu (IT)/h
Table 16: Power consumption/power output