Getting Started with iControl
Disabling Superfluous Lookup Services
3 In
Network Connections
, right-click the network adapter you wish to configure (e.g.,
Local Area Connection,
or
Ethernet
), and then click
Properties
. If the system prompts you
for an administrator password or confirmation, type the password or provide
confirmation.
The Properties window for the selected network adapter opens.
4 On the
Networking
tab, under
This connection uses the following items
, click
Internet Protocol Version 4 (TCP/IPv4)
, and then click
Properties
.
The
Internet Protocol Version 4 (TCP/IPv4) Properties
window opens.
5 Take note of the PC’s current settings.
6 On the
General
tab, click
Use the following IP address
.
The default IP address of a new Application Server is 10.0.3.6.
7 Type an IP address in the same range (e.g.,
10.0.3.10
), in the
IP address
box.
The default subnet mask of a new Application Server is 255.255.0.0.
8 Type
255.255.0.0
, in the
Subnet mask
box.
9 Click
OK
.
10 In
Local Area Connection Properties
, click
Close
.
Step 4: Optional Networking Setup
Once the Application Server is plugged into and available on your network, you may need
to configure additional settings to permit it to operate in that environment.
• Disable superfluous Lookup Services (see
Disabling Superfluous Lookup Services
• Configure alarm discovery locations (see
Specifying Service and Alarm Discovery
• Activate serial ports (see
• Activate the iControl Services Gateway (see
Activating the iControl Services Gateway
• Configure date and time settings (see
Configuring an Application Server’s Date and
• Add mappings to client workstations’ hosts files (see
Configuring Client Workstations
for Better Streaming Performance
Disabling Superfluous Lookup Services
iControl uses a lookup service for discovery over a network. By default, each iControl
Application Server runs a lookup service that registers and makes available information
Notes
• The factory-default IP address and subnet mask settings for an Application
Server appear on a sticker, on the top cover of the chassis.
• Remember to return the PC to its original network settings once you have
finished configuring the Application Server.