GUIDE TO INSTALLATION AND OPERATION
4
| ADX-1901
To install the connector panel:
Note – the procedure is the same for both Densité-2 and Densité-3 frames.
1. If a card is installed in the slot whose rear panel is being changed, remove it as described above.
2. Remove the existing panel (either blank or belonging to an existing card that is being changed) by releasing the
captive screw(s) at the bottom.
3. Position the new panel and secure it in place with the captive screw(s) at the bottom.
2.2 ADX-1901 Card Installation
Note – The card itself (ADX-1901) is designed to fit the Densité-2 frame. If it was ordered for the Densité-3 frame
(ADX-1901-3RU), it will be delivered with an installed adapter that allows it to fit into the taller frame. The
adapter can be ordered separately and user-installed if required.
Once a matching rear connector panel is in place, install the ADX-1901 card as follows:
1. Open the front panel of the frame.
2. Slide the ADX-1901 card into the slot and push gently on the handle to seat the connectors.
When using the double-slot-width rear panel in a Densité-2 frame, the card should be inserted into the right-
most of the two slots. Inserting the card into the wrong slot will not damage the card, and will be flagged by the
on-card status LED flashing red to indicate that there is no connection to the rear panel.
3. Close the front panel of the frame.
2.3 Installation of the Optical Interface (option)